Differential Scanning Calorimetry Dsc Analysis
Product advantages:
Temperature sensitivity of up to 0.001
The software's multianalysis features allow for the opening of multiple curves for analysis.
A U-shaped metal furnace body for high repeatability
Follow us on Facebook and Youtube.
Click this link to find out more about thermal analyzers.
SKZ1052 differential scanning calorimetry dsc analysis
Performance testing, quality control, and polymer research all make extensive use of DSC.The goal is to determine how temperature and heat flow relate to the inner heat transition.DSC research and development encompasses the domains of glass transition temperature,melting point, phase transition, cold crystallization, and oxidation induction time (OIT).
Standards:
ISO/TR10837:1991, ASTM D3895-1998, ASTM E 967, ASTM E 968, ASTM E 793, ASTM D 3895, ASTM D 3417, ASTM D 3418, ISO 11357-6
Product features:
1. A 7inch touch screen of industrial quality displays rich information.
2. A completely redesigned metal furnace body structure with enhanced baseline and precision.The method employed is indirect conduction heating, which reduces pulse radiation and has excellent uniformity and stability over standard heating modes.
3. The USB communication interface is characterized by strong flexibility, dependable and continuous communication, and support for the self-recovery connection function.
4. A fast stabilization time and switching speed are associated with the automatic activation of the two-channel atmosphere flow. Concurrently added is a protective gas input as well.
5. The program is simple to use and intuitive.
Temperature range | RT~ 550 ℃ |
Heating rate | 0.1~80℃/min |
Temperature resolution | 0.001℃ |
Temperature fluctuations | ±0.001℃ |
Temperature repeatability | ±0.1℃ |
Constant temperature time | Program setting ≤24h |
DSC range | 0~±600Mw |
DSC noise | 0.01Μw |
DSC resolution | 0.01Μw |
DSC accuracy | 0.01Mw |
Atmosphere control gas | Nitrogen, Oxygen (instrument switch automatically) |
Gas flow rate | 0-300Ml/min |
Gas pressure | 0.2Mpa |
Control Mode | Rising temperature, constant temperature (fully automatic) |
Curve scanning | Rising scan |
Gas flow control | Built-in digital flow meter & Software control, automatic |
Display | 24-bit 7 inches LCD touch screen display |
Data interface | standard USB connector |
Parameter standard | With standard material, with calibration function, the user may correct temperature and heat enthalpy |
Software | operating software |
Thermocouples | Total 3 sets of thermocouples for: 1). Test sample temperature 2). test furnace temperature, 3). Test internal ambient temperature |
Cooling device | Air cool |
Power | AC220V/50Hz |