Gas CLO2 Leak Detection Device
Introduction:
It adopts 2.5-inch high-definition shade display for real-time display, and adopts fuel sensors of frequent manufacturers in the industry.
It is used to shortly notice the attention of quite a number gases and the dimension of ambient temperature and humidity, and alarm if the size exceeds the limit.
It is appropriate for detecting fuel attention in pipelines or limited areas and atmospheric environments; fuel leakage or excessive attention single fuel purity the place a number of heritage gases are nitrogen or oxygen. There are greater than five hundred sorts of detected gases.
SKZ2050-4 CLO2 Gas Detector real model video. click here. and more
follow us on youtube and face book
Introduction to Portable Gas Detectors
Chlorine dioxide is a powerful disinfectant with a wide range of uses, which can be used in the food preservation industry as well as paper bleaching. A high-precision portable CLO2 gas detector can help people control the concentration of CLO2. Our SKZ2050-5 portable gas detector uses high-precision sensors with a response time of less than 1 second
Features:
●Standard USB charging, with charging protection function, support USB plug
It can be charged by a computer or a power bank, compatible with mobile phone chargers It has overcharge, over-discharge, over-voltage, short circuit, and overheat protection 5-level accurate power display The detector can work normally when charging.
●Using 5500mA large-capacity rechargeable polymer battery, which can work continuously for a long time.
●High-precision temperature and humidity measurement (optional).
●Support real-time detection or timing detection
The pump can be turned off when not testing to extend the start-up time.
●Multiple alarm methods, multi-directional three-dimensional indication of alarm status when alarming
Including sound and light alarm, vibration alarm, visual alarm on the display screen. The alarm types include: concentration alarm, under voltage alarm, and fault alarm.
●Multiple alarm mode settings
Low alarm, high alarm, interval alarm, weighted average alarm.
●Mistaken operation recognition function
Mis-operation of concentration calibration is automatically identified and prevented, which can
avoid defects caused by human factors.
●Zero point automatic tracking, long-term use will not be affected by zero point drift.
●Multi-level calibration of target points to ensure linearity and accuracy of measurement.
●Chinese and English interface can be selected.
●Wide working temperature: -40~+70℃, support temperature compensation.
●Logging
Record calibration log, maintenance log, troubleshooting countermeasures, reminder of the expiration of sensor life, reminder of the next concentration calibration time.
●Meet the design requirements of intrinsically safe circuit, anti-static,
anti-electromagnetic interference.
●Protection grade reaches IP66, waterproof, dust-proof, explosion-proof and shockproof.
Detection gas | CLO2 | |||||
Scope of detection | Customizable | |||||
Resolution | Customizable | |||||
Detection principle | Electrochemical principles | |||||
Sensor life | 2-3 years | |||||
Detection method | Built-in pump suction, flow rate 500ml/min | |||||
Display method | 2.5 inch 320X240 high-definition color screen display, 5-buttons operation | |||||
Detection accuracy | ≤±2%F.S | |||||
Linearity | ≤±2% | Repeatability | ≤±2% | |||
Alarm method | Sound and light alarm, vibration alarm, visual alarm, sound and light + vibration + visual alarm, shut off the alarm | |||||
Response time | ≤20S | Recovery Time | ≤30S | |||
Power supply | DC3.6V | |||||
battery capacity | 3.6VDC, 5500mA large-capacity rechargeable polymer battery, with overcharge, over-discharge, over-voltage, overheating, and short circuit protection functions | |||||
Use environment | Temperature -40℃~+70℃; Relative humidity ≤0-99%RH (built-in filter can be used in high humidity or high dust environment) | |||||
Sample temperature | -40℃~+70℃, optional with extra charge high temperature sampling probe,can detect the flue gas concentration of 800 degrees or higher | |||||
Temperature measurement | -40℃~+120℃ Accuracy: 0.5℃ | Humidity measurement | 0-100%RH, Accuracy 3%RH | |||
data storage | Standard configuration of 100,000 data capacity, support history viewing, deletion or data export, free host computer communication software. |
The storage function is off by default, and can be set to on, and the storage time interval can be set arbitrarily. | ||||
Communication Interface | USB (charging and communication), RS232, infrared communication, automatic identification | |||
Printer | Optional extra charge external mini wireless infrared thermal printer | |||
Interface language | Chinese or English can be set | |||
Explosion-proof type | Intrinsic safe | Explosion-proof mark | ExdⅡCT6 | |
Protection level | IP66, dust and splash proof | |||
Dimensions | 180×78×33mm(L×W×H) | Weight | 350g | |
Standard accessories | Manual, certificate of inspection and warranty card, USB charger (including data cable), aluminum alloy box, alligator clip, host computer communication software, 5PCS humidity dust filter | |||
Optional accessories | 1.2 m retractable sampling probe (standard is 1 meter), temperature and humidity measurement function, high temperature sampling probe, high temperature and high humidity pretreatment system, multiple humidity and dust filters, lanyard, external mini wireless infrared printer | |||
Application occasions | Petroleum, chemical, pharmaceutical, environmental protection, flue gas analysis, air treatment and other occasions where gas concentration needs to be detected. |
Related News