5 Gas Monitor
For real-time display, it uses a 2.5-inch high-definition color screen. Gas sensors are from reputable manufacturers in the market.
It can instantly determine the concentration of different gases, measure the humidity and ambient temperature, and sound an alert if a measurement goes above or below the set limit.
It can be used to detect concentrations of gas in pipelines, restricted spaces, and atmospheric conditions; it can also be used to detect leaks of gas or large concentrations of pure gas in situations when the background gases are nitrogen or oxygen.
SKZ2050-5-Multi Gas Detector video. click here. and more.
SKZ2050-5 5 Gas Monitor
Introduction:
For real-time display, it uses a 2.5-inch high-definition color screen. Gas sensors are from reputable manufacturers in the market.
It can instantly determine the concentration of different gases, measure the humidity and ambient temperature, and sound an alert if a measurement goes above or below the set limit.
It can be used to detect concentrations of gas in pipelines, restricted spaces, and atmospheric conditions; it can also be used to detect leaks of gas or large concentrations of pure gas in situations when the background gases are nitrogen or oxygen.
Features:
1.It has the ability to simultaneously detect one to five different types of gases and is switchable:
Optional units: ppb, mg/L, PPHM, mg/m3, VOL%, LEL%, and PPM
2.Features include built-in pump measurement, an integrated water vapor and dust filter, fast response times, support for long-distance sampling, and the ability to be utilized in environments with high humidity and dust levels without causing harm to sensors or equipment.
3.Enhanced interface between machines and humans.Real-time concentration, alarm, time, temperature, humidity, storage, communication, power, charging status, concentration unit, gas molecular formula, gas name, and other information are displayed on the 2.5-inch high-definition color screen. The menu interface displays the function names of each menu using high-definition simulation graphics.
4.Large-capacity data storage capability with support for various storage techniques a standard 100,000 data storage capacity, with the option to customize a greater capacity; the ability to store data in real-time, on schedule, or just for alarm concentration;This device supports viewing and deleting data. Data can also be uploaded via an RS232 or USB interface, and advanced computer software can be used to analyze, save, and print the data.
5.Flue gas up to 800 degrees can be detected using an optional high-temperature sampling and cooling filter handle or high-temperature and high-humidity pre-treatment system. Gas detection at higher temperatures can be tailored.
6.The concentrations of one to five gases are shown simultaneously, together with a real-time curve display and a circular, large-type display of the concentration of a single-channel gas.
7.Create a curve that represents the trend of changes in gas concentration over time.
8.To eliminate concerns brought on by errors in operation, you can decide whether to recover fully or partially.
9.Has the option to show the average, minimum, and maximum numbers.
10.Typical USB charging that supports USB plugs and has a charging protection feature
Both a computer and a power bank may charge it, and it is compatible with chargers for cell phones. It is protected against short circuit, overheat, overcharge, overdischarge, and overvoltage. Accurate power display with five levels. While charging, the detector can function normally.
11.Using a large-capacity rechargeable polymer battery (5500mA) that can run continuously for an extended period of time.
12.Measurement of humidity and temperature with high precision (optional).
13.Encourage timing or real-time detection.If you want to prolong the start-up time, you can turn off the pump when not in use.
14.When sounding, there are numerous alarm options and a multidirectional, three-dimensional indicator of the alarm condition.Including vibrating alarm, light and sound alarm, and display screen visual alarm. The three categories of alarms are fault, under-voltage, and concentration.
15.There are many settings for the alarm modes, including low, high, interval, and weighted average.
16.Defects brought on by human factors can be avoided by automatically detecting and stopping concentration calibration errors.
17.Zero point drift won't have an impact on long-term use with zero point automatic tracking.
18.Target points are calibrated on multiple levels to guarantee measurement accuracy and linearity.
19.You can choose between an English or Chinese UI.
20.Wide operating temperature range: -40°C to 70°C; temperature adjustment supported.
21.Logging: Keep track of your calibration and maintenance logs, troubleshoot countermeasures, remember when the sensor's life is about to expire, and remember when the next concentration calibration is scheduled.
22.Fulfill the anti-static, anti-EMC interference, and fundamentally safe circuit design criteria.
23.IP66 protection level, dust-proof, shock-proof, explosion-proof, and waterproof.
Specification
Detection gas | CO/O2/NOX/CO2/HC |
Scope of detection | CO:0-20000PPM O2:0-30%VOL NOX:0-1000PPM CO2:0-20%VOL HC:0-10000PPM |
Resolution | CO:1PPM O2:0.01%VOL NOX:1PPM CO2:0.01%VOL HC:1PPM |
Detection principle | Electrochemical principles/Infrared principles |
Sensor life | 2-3 years |
Detection method | Built-in pump suction, flow rate 500ml/min |
Display method | 2.5 inch 320X240 high-definition color screen display, 5-buttons operation |
Detection accuracy | ≤±2%F.S |
Repeatability | ≤±2% |
Linearity | ≤±2% |
Alarm method | Sound and light alarm, vibration alarm, visual alarm, sound and light + vibration + visual alarm, shut off the alarm |
Response time | ≤20S |
5 gas monitor | ≤30S |
Power supply | DC3.6V |
battery capacity | 3.6VDC, 5500mA large-capacity rechargeable polymer battery, with overcharge, over-discharge, over-voltage, overheating, and short circuit protection functions |
Use environment | Temperature -40℃~+70℃; Relative humidity ≤0-99%RH (built-in filter can be used in high humidity or high dust environment) |
Sample temperature | -40℃~+70℃, optional with extra charge high temperature sampling probe, can detect the flue gas concentration of 800 degrees or higher |
Temperature measurement | -40℃~+120℃ Accuracy: 0.5℃ |
Humidity measurement | 0-100%RH, Accuracy 3%RH |
data storage | Standard configuration of 100,000 data capacity, support history viewing, deletion or data export, free host computer communication software. |
The storage function is off by default, and can be set to on, and the storage time interval can be set arbitrarily. | |
Communication Interface | USB (charging and communication), RS232, infrared communication, automatic identification |
Printer | Optional extra charge external mini wireless infrared thermal printer |
Interface language | Chinese or English can be set |
Explosion-proof type | Intrinsic safe |
Explosion-proof mark | ExdⅡCT6 |
Protection level | IP66, dust and splash proof |
Dimensions | 180×78×33mm(L×W×H) |
Weight | 350g |
Standard accessories | Manual, certificate of inspection and warranty card, USB charger (including data cable), aluminum alloy box, alligator clip, host computer communication software, 5PCS humidity dust filter |
Optional accessories | 1.2 m retractable sampling probe (standard is 1 meter), temperature and humidity measurement function, high temperature sampling probe, high temperature and high humidity pre-treatment system, multiple humidity and dust filters, lanyard, external mini wireless infrared printer |
Application occasions | Petroleum, chemical, pharmaceutical, environmental protection, flue gas analysis, air treatment and other occasions where gas concentration needs to be detected. |