Mullen Bursting Tester
Burst tester is the simple instrument for checking out the anti-bursting diploma of paper or cardboard, the usage of Mullen check methods.
Application
It is used to decide a range of paper and no longer extra than 2000kpa monolayer of skinny cardboard, or a range of single and multi-layer cardboard and corrugated cardboard can additionally be used to notice silk cotton and different non-paper products.
Kindly check the video of SKZ108AB Bursting Tester
Please click here to learn more about paper and paperboard testing
Follow us on Youtube and Facebook
Burst tester is the simple instrument for checking out the anti-bursting diploma of paper or cardboard, the usage of Mullen check methods.
Application
It is used to decide a range of paper and no longer extra than 2000kpa monolayer of skinny cardboard, or a range of single and multi-layer cardboard and corrugated cardboard can additionally be used to notice silk cotton and different non-paper products.
Standards
ISO2759, ISO 2758.
Principle
It adopts signal transmitting press. When the specimen is burst, the tester stores the maximum of bursting strength automatically.
The sample placed on the membrane, with sample holder clamping and hydraulic pressure evenly, sample free raised together with the membrane, until the sample burst, the maximum hydraulic pressure strength is the burst value of the sample.
Features
1. Micro-computer control, use hydraulic oil as the driving force to break the specimen.
2. When the specimen is broken, it stores the maximum and reset automatically.
3. LCD displays.
4. It adopts signal transmitting press
5. Built-in printer, high speed print out the test results.
6. ISO 2759 and ISO 2758.
Items | Specification | ||
Type | SKZ108A Paper type | SKZ108B Cardboard type | |
Measure range | 50-1600kPa | 250~6000Kpa | |
Pressure between platen | >430kPa | >690 Kpa | |
Transmit hydraulic speed | 95±5ml/min | 170±15ml/ min | |
Diaphragm resistance | Protruding 9mm: (20-40)mm | Protruding 10mm,(170-220) mm Protruding 18mm,(250-350) mm | |
Continuous testing time | 5s | ||
Resolution | 1Kpa | ||
Accuracy | ±0.5%F.S | ||
Hydraulic system tightness | On the measurement limit, one minute drop <10% Pmax | ||
Upper platen aperture dia. | (30.5±0.05)mm | (31.5±0.05)mm | |
Lower platen aperture dia. | (33.5±0.05) mm | (31.5±0.05) mm | |
Dimensions | 440 mm(L)×370 mm(W)×520 mm(H) | ||
Motor Power | 90W | ||
Power supply | 220V±10% 50Hz | ||
Weight | 55kg |