Water Quality Analyzer

4.3-inch color LCD touchscreen with high contrast.
Auto, timed, and continuous reading are all possible with the multi-reading feature.
Accurate findings are ensured by automatic or manual temperature correction.
The measurement endpoint is sensed and locked by the auto-hold feature.
Up to 500 sets of data can be stored for any parameter (GLP-compliant).
USB communication support is provided.
The battery service life is significantly increased by the auto-power-off feature.

More water quality analyzer,click here

Follow us on Facebook and Youtube

Contact Now E-Mail Telephone WhatsApp
Product Details

M310T Water Quality Analyzer

GENERAL FEATURES

4.3-inch color LCD touchscreen with high contrast.
Auto, timed, and continuous reading are all possible with the multi-reading feature.
Accurate findings are ensured by automatic or manual temperature correction.
The measurement endpoint is sensed and locked by the auto-hold feature.
Up to 500 sets of data can be stored for any parameter (GLP-compliant).
USB communication support is provided.
The battery service life is significantly increased by the auto-power-off feature.
The "Reset" feature automatically returns all settings to their original factory settings.
IP65 water resistance. Field measurements and outdoor measurements can be performed using the portable meter.

pH

Calibrating with standard recognition for 1–5 points.
pH buffer groups that can be chosen, such as NIST, DIN, GB, and USA.
Automated electrode diagnostic featuring offset display and pH slope. 

Ion

Calibration points: 1–5.

Measurement units that can be used, such as μg/L, mg/L, g/L, mmol/L, pX, ppm, ppb, and so on.
The following measurement modes are supported: GRAN, Sample Addition, Standard Addition, and Direct Reading.
User-defined techniques are available in addition to the more than ten built-in methods (F-, Cl-, Br-, I-, NO3-, BF4-, NH4+, K+, Na+, Ca2+, Cu2+, Pb2+, Ag+, and so on). 

Conductivity

Calibration of 1-3 points using Standard Recognition.

TDS factor, temperature compensation coefficient, and cell constant are examples of variables that can be changed.
Kind of temperature compensation (linear, pure water, none). 

DO

Support for zero oxygen calibration or air-saturated water.

Automatic barometric pressure adjustment
Correction of the Salinity Factor by Hand
Variable pressure unit selection, including Torr, Atm, mbar, and kPa. 

Includes

E-301-QC 3 in 1 pH composite electrode

DJS-1VTC EC electrode

DO-958-Q polarographic DO electrode

NIST pH standard solution(4.01, 7.00, 10.01) , 50ml/vial

1413μS/cm EC standard solution, 50ml, 1 vial

Electrode holder

Silicone rubber case

Wristbands

Carrying Case

Parameter list

Model

M310T

Parameters

pH/EC/ISE/DO/Temp. (mV/pX/Resistivity/TDS/Sal./DO Saturation)

pH

Range

-2.00 to 20.00 pH


Resolution

0.1, 0.01 pH


Accuracy

±0.01 pH


Calibration Points

Up to 5


Standard Customization

Yes


Calibration Reminder

Yes


Standard Recognition

NIST, GB, USA and DIN buffers


Slope Limit

Yes

mV

Range

-2000.0 to 2000.0 mV


Resolution

0.1 mV


Accuracy

±0.3 mV or ±0.1%

pX

Range

-2.00 to 20.00 pX


Resolution

0.1, 0.01 pX


Accuracy

±0.01 pX


Calibration Points

Up to 5

ISE

Range

1.000e-9 to 9.999e+9


Units

mol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppb


Resolution

Up to 4 significant digits


Accuracy

±0.5%


Calibration Points

Up to 5

Conductivity

Range

0.000 μS/cm to 1000 mS/cm


Resolution

0.001 μS/cm minimum,

various with range selection


Accuracy

±1.0% FS


Reference Temperature

20, 25 ºC


Calibration Points

Up to 3


Standard Recognition

84μS/cm, 1413μS/cm, 12.88mS/cm

Resistivity

Range

5.00 Ω·cm~20.00 MΩ·cm


Resolution

0.01Ω ·cm minimum,


Accuracy

±1.0% FS

TDS

Range

0.00 ppm~300 ppt


Resolution

0.01mg/L minimum, 3 significant digits


Accuracy

±1.0%FS

Salinity

Range

0.0~80.0 ppt


Resolution

0.1ppt


Accuracy

±2ppt

Dissolved

Oxygen Concentration

Sensor Type

Polarographic


Range

0.00 to 50.00 ppm


Resolution

0.01mg/L 


Accuracy

±0.10ppm


Calibration Points

Air-saturated water or zero point


Barometric Compensation

Yes


Manual Salinity Factor Correction

Yes

Saturation

Range

(0.0 to 300.0)%


Resolution

0.10%


Accuracy

±2.0%

Temperature

Range

-5 to 110 ºC, 23.0 to 230 ºF


Unit

ºC, ºF


Resolution

0.1


Accuracy

±0.2ºC

Measurement

Reading Mode

Auto-Read (Fast, Medium, Slow), Timed, Continuous


Reading Prompts

Reading, Stable, Locked


Temp. Compensation

ATC, MTC

Data management

Data Storage

1000 Groups


GLP Features

Yes

Inputs

pH Electrode

BNC(Q9)


DO with Temp. Probe

4-pin aviation connector


Conductivity with Temp. Probe

5-pin aviation connector

Outputs

USB

PC, printer

Display options

Backlight

Yes


Auto Shutdown

300, 600, 1200, 1800, 3600sec., off


IP Rating

IP65


Date and Time

Yes

General

Power

Rechargeable Lithium battery, AC Adapter, 100-240V AC input, DC5V output


Dimensions

90 x 255 x 40 mm


Weight

500g (1.1 lb)


Dimensions (Carton)

490×410×220 mm


Weight (Gross)

5.5 kg

Water Quality Analyzer

Water Quality Analyzer

Water Quality Analyzer

Water Quality Analyzer

Water Quality Analyzer

Water Quality Analyzer

Water Quality Analyzer

Water Quality Analyzer



Leave your messages

Related Products

Related News

Popular products

x

Submitted successfully

We will contact you as soon as possible

Close