Orp Meter
4.3-inch color LCD touchscreen with high contrast.
Features offered by an intelligent operation system include data management, log management, electrode management, user administration, calibration management, method management, and more.
Auto, timed, and continuous reading are all possible with the multi-reading feature.
Accurate findings are ensured by automatic or manual temperature correction.
The measurement endpoint is sensed and locked by the auto-hold feature.
1000 sets of data storage for every parameter (compatible with GLP).
More water quality analyzer,click here. Follow us on Facebook and Youtube.
Features:
4.3-inch color LCD touchscreen with high contrast.
Features offered by an intelligent operation system include data management, log management, electrode management, user administration, calibration management, method management, and more.
Auto, timed, and continuous reading are all possible with the multi-reading feature.
Accurate findings are ensured by automatic or manual temperature correction.
The measurement endpoint is sensed and locked by the auto-hold feature.
1000 sets of data storage for every parameter (compatible with GLP).
Utilizing the data analysis feature, users can examine, contrast, and recalculate results.
USB communication support is provided.
The battery service life is significantly increased by the auto-power-off feature.
The "Reset" feature automatically returns all settings to their original factory settings.
IP65 water resistance. Field measurements and outdoor measurements can be performed using the portable meter.
pH
1-8 points calibration with Standard Recognition.
Selectable pH buffer groups, including USA, NIST, DIN, GB, MERK, JIS.
User-defined pH buffer or buffer group is supported.
Automatic electrode diagnosis with pH slope and offset display.
Ion
1-6 points calibration.
Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, pX, ppm, ppb, etc.
Multi-measurement modes are supported, including Direct Reading mode, Standard Addition mode, Sample Addition mode and GRAN mode.
Over 10 methods are built-in, including F-, Cl-, Br-, I-, NO3-, BF4-, NH4+, K+, Na+, Ca2+, Cu2+, Pb2+, Ag+ and etc., user-defined method is supported.
Conductivity
1-5 points calibration automatically recognizes the standard solutions.
Settable parameters, including cell constant, reference temperature (5/10/15/18/20/25°C), temperature compensation coefficient and TDS factor.
Temperature compensation type (none, linear, pure water).
DO
Support for air-saturated water or zero oxygen calibration.
Auto barometric pressure compensation
Manual Salinity Factor Correction
Selectable pressure unit, including kPa, mbar, Torr, Atm.
Includes
E-301-QC 3 in 1 pH composite electrode
DJS-1VTC EC electrode
DO-958-Q polarographic DO electrode
NIST pH standard solution(4.01, 7.00, 10.01) , 50ml/vial
Electrode holder
Silicone rubber case
Wristbands
Touch pen
Carrying case
Model | M510T | |
Parameters | pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation) | |
pH | Range | -2.000 to 20.000 pH |
Resolution | 0.1, 0.01, 0.001pH | |
Accuracy | ±0.002 pH | |
Calibration Points | Up to 8 | |
Standard Customization | Yes | |
Calibration Reminder | Yes | |
Standard Recognition | USA, NIST, MERK, JIS, GB and DIN buffers | |
Slope Limit | Yes | |
mV/ORP | Range | -2000.00 to 2000.00 mV |
Resolution | 0.1, 0.01 mV | |
Accuracy | ±0.1 mV or ±0.03% | |
EH ORP Mode | Yes | |
ORP Calibration Points | 1 custom point (relative mV) | |
pX | Range | -2.000 to 20.000 pX |
Resolution | 0.1, 0.01, 0.001 pX | |
Accuracy | ±0.002 pX | |
Calibration Points | Up to 6 | |
ISE | Range | 1.000e-9 to 9.999e+9 |
Units | mol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppb | |
Resolution | Up to 4 significant digits | |
Accuracy | ±0.3% | |
Calibration Points | Up to 8 | |
Conductivity | Range | 0.000 μS/cm to 3000 mS/cm |
Resolution | 0.001 μS/cm minimum, various with range selection | |
Accuracy | ±0.5% FS | |
Reference Temperature | 5, 10, 15, 18, 20, 25 ºC | |
Calibration Points | Up to 5 | |
Calibration Reminder | Yes | |
Standard Recognition | 10μS/cm, 84μS/cm, 500μS/cm, 1413μS/cm, 12.88mS/cm; 146.5μS/cm, 1408μS/cm, 12.85mS/cm, 111.3mS/cm | |
Resistivity | Range | 5.00 Ω·cm~100.0 MΩ·cm |
Resolution | 0.01 Ω·cm minimum | |
Accuracy | ±0.5% FS | |
TDS | Range | 0.000 ppm~1000 ppt |
Resolution | 0.001ppm minimum, changed with range | |
Accuracy | ±0.5% FS | |
Salinity | Range | 0.0~80.0 ppt |
Resolution | 0.1ppt | |
Accuracy | ±1ppt | |
Dissolved Oxygen Concentration | Sensor Type | Polarographic |
Range | 0.00 to 99.99 ppm | |
Resolution | 0.01 ppm | |
Accuracy | ±0.10ppm,(0.00~50.00)ppm ±0.50ppm,(50.0~99.99)ppm | |
Calibration Reminder | Yes | |
Calibration Points | Air-saturated water or zero point | |
Barometric Compensation | Yes | |
Manual Salinity Factor Correction | Yes | |
Saturation | Range | (0.0 to 600.0)% |
Resolution | 0.10% | |
Accuracy | ±2.0% | |
Temperature | Range | -10 to 135 ºC, 14 to 275 ºF |
Unit | ºC, ºF | |
Resolution | 0.1 | |
Accuracy | ±0.1ºC | |
Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
Reading Prompts | Reading, Stable, Locked | |
Temp. Compensation | ATC, MTC | |
Data management | Data Storage | 1000 Groups |
GLP Features | Yes | |
Inputs | pH Electrode | BNC(Q9) |
DO with Temp. Probe | 4-pin aviation connector | |
Conductivity with Temp. Probe | 5-pin aviation connector | |
Outputs | USB | USB 2.0 flash memory device, PC, scanner |
Display options | Backlight | Yes |
Auto Shutdown | 300, 600, 1200, 1800, 3600 sec., off | |
IP Rating | IP65 | |
Date and Time | Yes | |
General | Power | Rechargeable Lithium battery, AC Adapter, 100-240V AC input, DC5V output |
Dimensions | 90×255×40 mm | |
Weight | 500g (1.1 lb) | |
Dimensions (Carton) | 490×410×220 mm | |
Weight (Gross) | 5.5 kg |
Related News
Submitted successfully
We will contact you as soon as possible