M500T 

Features:

Color High contrast LCD touchscreen, 7.0 inches.

Intelligent operation system provides features including user management, calibration management, method management, data management and etc. 

Multi-reading feature allows auto-read, timed-read and continuous-read. 

Automatic/Manual temperature compensation ensures accurate results. 

Data Storage 1000 sets for each parameter (GLP-compliant).

Data analysis feature helps user review, compare and recalculate results.

Support for USB or RS-232 communication.

Reset feature automatically resumes all settings back to factory default options.

IP54 waterproof.

pH

1-6 points calibration with Standard Recognition.

Selectable pH buffer groups, including DIN, NIST, USA, MERK, JIS, GB.

Support for pH standard group customization.

Automatic electrode diagnosis with pH slope and offset display.

Ion

1-6 points calibration

Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, pX, ppm, ppb, etc.

Multi-measurement modes are supported, including Direct Reading mode, Standard Addition mode, Sample Addition mode and GRAN mode.

Over 10 methods are built-in, including F-, Cl-, Br-, I-, NO3-, BF4-, NH4+, K+, Na+, Ca2+, Cu2+, Pb2+, Ag+ and etc., user-defined method is supported.

Conductivity

1-5 points calibration with Standard Recognition.

Settable parameters, including cell constant, reference temperature (5/10/15/18/20/25°C), temperature compensation coefficient and TDS factor.

Temperature compensation type (none, linear, pure water).

DO

Support for air-saturated water or zero oxygen calibration.

Auto barometric pressure compensation. 

Manual Salinity Factor Correction.

Selectable pressure unit, including kPa, mbar, Torr, Atm.

Includes

E-301-QC 3 in 1 pH composite electrode

DJS-1VTC EC electrode

DO-958-Q polarographic DO electrode

NIST pH standard solution(4.01, 7.00, 10.01) , 50ml/vial

1413μS/cm EC standard solution, 50ml, 1 vial

REX-6 electrode stand

Touch pen

Specifications

Model

M500T

Parameters

pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation)

pH

Range

-2.000 to 20.000 pH


Resolution

0.1, 0.01, 0.001pH


Accuracy

±0.002 pH


Calibration Points

Up to 6


Standard Customization

Yes


Calibration Reminder

Yes


Standard Recognition

NIST, GB, DIN, USA, MERK, JIS buffers


Slope Limit

Yes

mV/ORP

Range

-2000.00 to 2000.00 mV


Resolution

0.1, 0.01 mV


Accuracy

±0.1 mV or ±0.03% of

reading whichever is greater


EH ORP Mode

Yes


ORP Calibration Points

1 custom point (relative mV)

pX

Range

-2.000 to 20.000 pX


Resolution

0.1, 0.01, 0.001 pX


Accuracy

±0.002 pX


Calibration Points

Up to 6

ISE

Range

1.000e-9 to 9.999e+9


Units

mol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppb


Resolution

Up to 4 significant digits


Accuracy

±0.3%


Calibration Points

Up to 6

Conductivity

Range

0.000 μS/cm to 2000 mS/cm


Resolution

0.001 μS/cm minimum,

various with range selection


Accuracy

±0.5% FS


Reference Temperature

5, 10, 15, 18, 20, 25 ºC


Calibration Points

Up to 5


Calibration Reminder

Yes


Standard Recognition

10 μS/cm, 84 μS/cm, 500 μS/cm, 1413 μS/cm, 12.88 mS/cm; 146.5μS/cm, 1408μS/cm, 12.85mS/cm, 111.3mS/cm

Resistivity

Range

5.00 Ω·cm~100.0 MΩ·cm


Resolution

0.01 Ω·cm minimum


Accuracy

±0.5% FS

TDS

Range

0.000~1000 ppt


Resolution

0.001 ppm minimum, changed with range


Accuracy

±0.5% FS

Salinity

Type

NaCl


Range

0.0~80.0 ppt


Resolution

0.1ppt


Accuracy

±1ppt

Dissolved

Oxygen Concentration - 

Polarographic

Range

0.00 to 99.99 ppm


Resolution

0.01 ppm


Accuracy

±0.10ppm,(0.00~50.00)ppm

±0.50ppm,(50.0~99.99)ppm


Calibration Reminder

Yes


Calibration Points

Air-saturated water or zero point


Barometric Compensation

Yes


Manual Salinity Factor Correction

Yes

% Saturation -

Polarographic

Range

 (0.0 to 600)%


Resolution

0.10%


Accuracy

±2.0%

Temperature

Range

-10 to 135 ºC, 14 to 275 ºF


Unit

ºC, ºF


Resolution

0.1


Accuracy

±0.1ºC

Measurement

Reading Mode

Auto Read (Fast, Medium, Slow), Timed, Continuous


Reading Prompts

Reading, Stable, Locked


Temp. Compensation

ATC, MTC

Data management

Data Storage

1000 Groups


GLP Features

Yes


Log Management

Yes

Inputs

pH Electrode

BNC(Q9)


DO with Temp. Probe

4-pin aviation connector


Conductivity with Temp. Probe

5-pin aviation connector

Outputs

USB

USB 2.0 flash memory device, PC, scanner,


RS 232

printer, auto-sampler

Display options

Backlight

Yes


Auto Shutdown

1~60 min, off


IP Rating

IP54


Date and Time

Yes

General

Power

AC Adapter, 100-240V AC input, DC24V output


Dimensions

220×195×68 mm


Weight

950g (2.09 lb)


Dimensions (Carton)

370×305×330 mm


Weight (Gross)

5.5 kg

Multiparameter Water Quality Meter

Multiparameter Water Quality Meter

Multiparameter Water Quality Meter

Multiparameter Water Quality Meter

Multiparameter Water Quality Meter

Multiparameter Water Quality Meter

Multiparameter Water Quality Meter

Multiparameter Water Quality Meter

Leave your messages

Related Products

Related News

Popular products

x

Submitted successfully

We will contact you as soon as possible

Close