Laboratory Turbidimeter
1. Streamlined, lightweight design, simple operation and cost-effective
2. Large-screen LCD digital clear display, low drift, high precision circuitry
3. Reliable structure and high precision optical systems, instruments long time stability
4. Chrominance compensation, effectively avoid the interference caused by the sample color, turbidity can accurately reflect
5. Long-life high-intensity light source, no replacement worries, 30 seconds warm-up time to work
SKZ1041A Laboratory Turbidimeter follow us on Facebook and Youtube. Learn more about Analysis instruments, click here.
Laboratory Turbidimeter SKZ1041A
For measuring suspended in water insoluble particulate matter generated by the degree of light scattering, to get the content of suspended particulate matter. Widely used in power plants, pure water plant, water plants and domestic sewage treatment plants, beverage plants, the environmental protection departments, industrial water, wine industry and the pharmaceutical industry, epidemic prevention departments, hospitals and other departments of the turbidity measurement.
Principle:
Turbidity, also called turbidity of water or transparent liquid. Caused by light scattering of insoluble suspended matter and colloidal substances in the water or clear liquid, ISO standard unit of measurement used FTU (turbidity units), FTU and NTU (turbidity units) consistent.
When light irradiated to the surface, the incident light, transmitted light, scattered light and the ratio between water turbidity of a certain relationship,
By measuring the transmitted light, scattered light and incident light or transmitted light and scattered light to determine the ratio of the turbidity of water samples.
Features:
1. Streamlined, lightweight design, simple operation and cost-effective
2. Large-screen LCD digital clear display, low drift, high precision circuitry
3. Reliable structure and high precision optical systems, instruments long time stability
4. Chrominance compensation, effectively avoid the interference caused by the sample color, turbidity can accurately reflect
5. Long-life high-intensity light source, no replacement worries, 30 seconds warm-up time to work
Technical Parameters:
Light source | Tungsten halogen lamp 6V, 12W |
Receiving elements | silicon photovoltaic cells |
Measuring range NTU | automatic range switching |
0.00 - 50.0, 50.1 - 200 (A type) | |
0.00 - 50.0, 50.1 – 200,201 - 2000 (B type) | |
Readings method | LCD touch digital display |
Indication error | 0-200NTU: not more than ± 8% (A type) |
201-2000NTU: not more than ± 6% (B type) | |
Indication stability | ≤ ± 0.3% FS |
Zero drift | ≤ ± 1% FS |
Sample vial | φ25mm × 95 mm |
Sample volume | 20ml ~ 30ml |
Power | 220 V ± 22V, 50 Hz ± 1Hz |
Dimensions | 358mm × 323mm × 160mm |
Weight | 8kg |