Ti-40 Titration Volumetric AnalysisGENERAL FEATURESLCD display screen and smart guide system.Titration methods, curves and results are displayed in detail.Replaceable burette with high-accuracy (10 ml or 20 ml selectable).Support the following titration modes: DET (dynamic equivalence point titration), MET (monotone equivalence point titration), SET (Preset Endpoint Titration) and MAT (manual titration).
Contact Now
Ti-50 Acid Base Titration Volumetric AnalysisGENERAL FEATURESA 7" vibrant touchscreen with a clever navigation system.Detailed displays of titration techniques, curves, and outcomes are provided.Installing an additional burette driver is optional.High-accuracy, replaceable burette (10 ml or 20 ml selectable).Features offered by intelligent operating systems include electrode management, titrant management, user management, method management, data management, and so forth.Provide support for the following titration modes: manual titration (MAT), SET (Preset Endpoint Titration), MET (m
Contact Now
SKZ1018B Karl Fischer Volumetric TitrationKarl Fischer titration method is utilized by the auto-analyzer to determine moisture content.Standards:ISO 10337,ASTM D 1744, ISO 760 , ASTM E203Qualities:1.A new speed drop function that measures a sample in tens of seconds using automatic control electrode polarization voltage drop speed2.Having an extra current meter makes the titration procedure easier to understand.3.Specially selected materials with exceptional corrosion resistance make up the whole fluid route, ensuring long-term continuous operation.4.The termination titration, which uses
Contact Now
SKZ1018C Fully Automatic Volumetric Karl Fischer TitrationAdopted Karl Fischer volumetric moisture can be measured liquids, solids and gases in the sample crystal water, adsorbed water, free water. StandardsISO 10337,ASTM D 1744, ISO 760 , ASTM E203Feature1. Huge variety LCD show, English menu activity.2. Full powerful showcase, WINDOWS working style simple to utilize.3. Shown at the same time (dampness content, rate, PPM content, reagent utilization), variety titration bend dynamic showcase4.
Contact Now
Volumetric Karl Fischer Titration SKZ1018BIt is auto-analyzer used Karl Fischer titration method,determination moisture content.Standards:ISO 10337,ASTM D 1744, ISO 760 , ASTM E203Features:1. New speed drop function, use automatic control electrode polarization voltage drop speed, measure a sample requires only tens of seconds2. Additional current meter makes the titration process more intuitive3. Entire fluid path is made of special materials selection, excellent corrosion resistance, to ensure long-term continuous operation4.
Contact Now
SKZ1018B Volumetric Karl Fischer TitrationIt is auto-analyzer used Karl Fischer titration method,determination moisture content. Standards:ISO 10337,ASTM D 1744, ISO 760 , ASTM E203Features:1. New pace drop function, use computerized manage electrode polarization voltage drop speed, measure a pattern requires solely tens of seconds2. Additional cutting-edge meter makes the titration procedure extra intuitive3.
Contact Now
Fully Automatic Volumetric Karl Fischer Titration SKZ1018CAdopted Karl Fischer volumetric moisture can be measured liquids, solids and gases in the sample crystal water, adsorbed water, free water. StandardsISO 10337,ASTM D 1744, ISO 760 , ASTM E203 Feature1. Large color LCD display, English menu operation.2. Full dynamic display, WINDOWS operating style easy to use.3. Displayed simultaneously (moisture content, percentage, PPM content, reagent consumption), color titration curve dynamic display4.
Contact Now
SKZ1018B Karl Fischer Moisture Water Content Test AnalysisIt is auto-analyzer used Karl Fischer titration method,determination moisture content.Standards:ISO 10337,ASTM D 1744, ISO 760 , ASTM E203Technical parameters:Measuring range3ppm-100% Resolution0.01mlMoisture titration Repeatability≤ 0.01Moisture titration linear correlation coefficient≥ 0.998Capacity error≤ ± 0.002Burette capacity>25mlSensitivity10-6ASKZ1018B VOLUMETRIC KARL FISCHER TITRATIONCan be realized:solvent inhalation,determination,enddisplay (alarm),waste water discharge,mixing by means of itsfunction keys.Complete a
Contact Now
SKZ1018B Efficient Moisture Volumetric Titration EquipmentThe SKZ1018B represents an advanced auto-analyzer that harnesses the Karl Fischer titration methodology for precise moisture content determination, adhering to renowned international standards such as ISO 10337, ASTM D 1744, ISO 760, and ASTM E203.
This state-of-the-art instrument comes packed with a suite of unique features designed to enhance performance and user experience:
1. A revolutionary speed drop mechanism has been implemented, which leverages automated control of the electrode polarization voltage drop pace.
Contact Now
It is auto-analyzer used Karl Fischer titration method,determination moisture content.Standards:ISO 10337,ASTM D 1744, ISO 760 , ASTM E203Features:1. New speed drop function, use automatic control electrode polarization voltage drop speed, measure a sample requires only tens of seconds2. Additional current meter makes the titration process more intuitive3. Entire fluid path is made of special materials selection, excellent corrosion resistance, to ensure long-term continuous operation4.
Contact Now
SKZ1062B Dry method laser particle size AnalyzerSpecifications1, measuring range: 0.1 to 800 microns 2. Accuracy: <± 1% (national standard D50) 3. Repeatability: <± 1% (national standard D50) 4, Power: AC 220 ± 10V, 50Hz, 200W 5. Dimensions: Host: 1000 × 330 × 300mm, dry injection system: 350 × 330 × 300mm 6, Weight: 40KG Dispersion method System includes a laser particle size analyzer, automatic dry dispersion system, composed of Silent oil free air compressor, high efficiency condenser section.
Contact Now
Wet Method Laser Particle Size Analyzer SKZ1062ATechnical parameter: Standard: ISO133201. Measuring range: 0.1~800 μm (SKZ1062A), 0.02~1200 μm (SKZ1062A-1)2. Accuracy tolerance: ± 1% (national standard D50) 3. Deviation of repeatability: ± 1% (national standard D50) 4.
Contact Now
SKZ117B Gloss TesterFunction: (1) One button to finish measuring a triangle: one action can finish measuring three angles; The three measuring light incidence angle standards specified in ISO 2813 are met by this method.
Contact Now
FEATURESColor High contrast LCD touchscreen, 4.3 inches.Intelligent operation system provides features including user management, calibration management, electrode management, method management, data management, Log Management and etc. Multi-reading feature allows auto-read, timed-read and continuous-read. Automatic/Manual temperature compensation ensures accurate results.
Contact Now
LCD Melt Flow Indexer MRF MVR Meter ISO1133 400degree MFI EquipmentStandards:ISO 1133-1:2011 Plastics — Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics —Part 1:Standard methodISO 1133-2:2011 Plastics — Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics —Part 2: Method for materials sensitive to time temperature history and/or moistureGBT 3682.1-2018 "Plastic Thermoplastic Melt Mass Flow Rate (MFR) and Melt Volume Flow Rate (MVR) Determination"ASTM D1238-2013 "Standard Test Method
Contact Now
SKZ148 Drop Dart Impact TesterThe impact resistance of plastic films and sheets is tested using a dart impact testing equipment, which uses a background light source to record test findings.StandardISO7765-85, GB9639-88, ASTM D1709 - 09 Technical parametersDart-head weight50-2000g, 5g/incremental (5g*5pcs,15g*15pcs, 30g*10pcs, 45g*10pcs, 80g*10pcs, 90g*15pcs)Dart-head semi-diameterA method: R19±1mm,B method: 25±1mmDart-head accuracy0.1%Impact height660mm, 1500mmImpact energy30JSample clamp deviceexternal dia.: 150mm, inside dia.: 125mmWorking t
Contact Now
SKZ XRY-1A+ Oxygen Bomb Calorimeter Description In ChemistryI. SummaryThe instrument is designed and made as per the National Standard of People’s Republic of China GB/T213-2008 and ASTM D240 Test Method for Calorific Value of coal, GB/T384-1988 Test Method for Calorific Value of Petroleum Products and Calibration Regulation of People’s Republic of China JJG672-2001 Oxygen Bomb CalorimeterII. Main technical specifications1. Power supply: AC 220V±5%, 50 Hz2. Total power consumption: ≤150W.3. Heat capacity: (14000~15000) J/K4. Resolution: 0.001 K5.
Contact Now
SKZ1038B Columetrico Karl Fischer TitrationDetermining the trace moisture content of solid, liquid, and gaseous materials using the Columetrico method. widely used in the production of alcohols, oils, fats, ethers, esters, acids, alkanes, benzene, amines, organic solvents, pesticides, phenols, drug raw materials, chemicals, petroleum, pharmaceuticals, and pesticides. Also used in the production of alcohols. Features:1.
Contact Now
Product DescriptionHigh Quality Fiber Fineness AnalyzerFor the measurement of fiber diameter, cross-sectional analysis and textile content. Projection microscope method,Mode of operation: manual measurement (A type), automatic measurement (B type), multi-point measurement; automatic statistical analysis, report printing, photo printing.Standards: GB/T 10685, FZ/T30003, AATCC 20A, SN/T0756Features:1. fiber qualitative analysis: FZ / T 01057.3 《textile fiber identification method of the third part of the microscopy experiments.》 AATCC 20 《fiber qualitative analysis.》 2.
Contact Now
M510T Orp MeterFeatures:4.3-inch color LCD touchscreen with high contrast.Features offered by an intelligent operation system include data management, log management, electrode management, user administration, calibration management, method management, and more.Auto, timed, and continuous reading are all possible with the multi-reading feature.Accurate findings are ensured by automatic or manual temperature correction.The measurement endpoint is sensed and locked by the auto-hold feature.1000 sets of data storage for every parameter (compatible with GLP).Utilizing the data analysis featur
Contact Now
M500T Features:Color High contrast LCD touchscreen, 7.0 inches.Intelligent operation system provides features including user management, calibration management, method management, data management and etc. Multi-reading feature allows auto-read, timed-read and continuous-read. Automatic/Manual temperature compensation ensures accurate results. Data Storage 1000 sets for each parameter (GLP-compliant).Data analysis feature helps user review, compare and recalculate results.Support for USB or RS-232 communication.Reset feature automatically resumes all settings back to factory
Contact Now
DO510T Portable Do MeterFeatures of the Product:1. Vibrant color contrast 4.3-inch touch screen LCD.2. User administration, calibration management, electrode management, method management, data management, log management, and other functions are provided by the intelligent operating system.3. The multi-reading feature enables timed, continuous, and automated reading.4. Accurate findings are ensured by the automatic or manual temperature correction mechanism.5. The measurement endpoint is sensed and locked by the auto hold function. 6.
Contact Now
Fiber Classifier (Bauer Fiber Classifier) is the equipment used for measuring the weight-average fiber length of pulp fiber according to screening method by pulp and paper-making laboratory. Principle:Screening the pulp suspension into the vessel, the vessel is charged with mesh sieve, Container into a ladder type, the pulp suspension flows from one container to another container, in various different sieve to retain the fiber length pulp, retention of pulp fiber length and the sieve mesh size.
Contact Now
SKZ156B Elmendorf Tear TesterUsed to test the degree and burst force of leather, non-woven textiles, and materials while they are simultaneously under force in all directions (elastic diaphragm method).Standards: ISO2960, ISO13938.1-04, ASTMD3786, JIS1018Features: 1. Meeting the 50cm2 testing area requirements2. Support system for sample clamps3. Facilitating online correspondence Product ParametersTesting range0-2 Mpa (B type)The min. value0.002MpaTest area50cm2(Φ79.8mm), (B type)Elastic mold-plate size≤2mmThe max. burst length70±0.02mmThe max.
Contact Now