SKZ120E Plastics Pipes Opacity TesterFor the determination of plastic pipes and fittings opacity measurement (displays the result as a percentage). Adopts Industrial Panel PC control, touch screen operation.
Contact Now
Suitable for all kinds of film, shrink film, heat shrink pipe, back plate. Such as the overall collection of various beverage packaging shrink film, shrink packaging film for medical packaging. Testing of the heat shrinking properties in a liquid medium at various temperatures.
Contact Now
TPS Thermal Conductivity Meter SKZ1061CProduct detailIt can be used for various heat conduction properties of different types of materials testing. Transient Plane Source method is to study the thermal conductivity method, the latest one, which makes measurement technology to a whole new level. In the study of material capable of fast and accurate measurement of thermal conductivity for the enterprise quality control, material production and laboratory studies provide a great convenience. The instrument is easy to operate, simple to understand, will not cause damage to
Contact Now
To determine charpy impact properties of plastics, rigid plastic sheet, pipe, digital type. FeatureHigh precision, easy to use, can be directly calculated impact energy, save 60 historical data, six kinds of units can be switched, display can show the angle and angle peak or energy.
Contact Now
SKZ1055 Differential Thermal AnalyzerDifferential thermal analysis: temperature under program control, the relationship and difference of temperature between the measured material and the reference.The DTA curves is to describe the changing relationship depending on temperature and time between the measured material and the reference compound. During the test, the sample temperature changes due to the phase change or an endothermic or exothermic reaction effects.
Contact Now
SKZ1061C Thermal Conductivity Testing Equipment PriceIt can be used for a number of warmth conduction residences of one-of-a-kind kinds of substances testing. Transient Plane Source technique is to learn about the thermal conductivity method, the ultra-modern one, which makes size technological know-how to a entire new level. In the find out about of cloth succesful of speedy and correct size of thermal conductivity for the employer first-class control, fabric manufacturing and laboratory research grant a outstanding convenience.
Contact Now
SKZ1053 Thermal Gravimetric AnalyzerWhen heating a material to look into its composition and thermal stability, thermogravimetric analysis (TG, TGA) is used to monitor changes in sample quality over time or at various temperatures.widely utilized in the development, manufacturing, quality assurance, and process optimization of polymers, rubber, coatings, medicines, catalysts, inorganic, metal, and composite materials.Uses: oxidation and reduction, breakdown process, moisture and volatiles, reaction kinetics, additions and fillers, adsorption and desorption, and quantitative component anal
Contact Now
SKZ1053 Automatic Thermo GravimetricAnalysis Tga PriceThermo gravimetric evaluation (TG, TGA) is to examine the exchange of pattern exceptional with temperature or time in the technique of heating and regular temperature, the reason is to learn about the thermal balance and composition of the material.Widely used in the lookup and development, procedure optimization and excellent manage of plastics, rubber, coatings, pharmaceuticals, catalysts, inorganic materials, steel substances and composite substancesController and software program advantages:1.
Contact Now
To determine the melt mass-flow MFR (g/10min), the melt volume-flow rate MFV(cm3/10min) and the melt density of thermo resin, for the engineering plastics of polycarbonate, nylon and fluorine plastics, whose melt temperature are higher, but also fit for the plastics tests of polyethylene, polystyrene, polypropylene, ABS resin and poly-formaldehyde resin, etc, whose melt temperature are lower, widely applied to the fields of plastics materials, product, petrochemical.Standards:ISO 1133-1:2011 Plastics — Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplas
Contact Now
SKZ1061C Thermal Conductivity Testing Equipment**
The SKZ1061C Thermal Conductivity Testing Equipment is an outstanding testing instrument that employs the advanced Transient Plane Source (TPS) technique.
Contact Now
SKZ145 Melt Flow Rate TesterMelt mass-flow (MFR) (g/10min), melt volume-flow rate (cm3/10min), and the melt density of thermo resin must be determined for engineering plastics, which have higher melt temperatures, such as polycarbonate, nylon, and fluorine plastics; and for fit for plastics tests, which have lower melt temperatures, such as polyethylene, polystyrene, polypropylene, ABS resin, and poly-formaldehyde resin, etc.Standards:ISO 1133-1, ISO 1133-2, GBT 3682.1-2018, ASTM D1238-2013, ASTM D3364-1999 (2011), JJG878-1994, JB/T5456-2016, DIN53735, UNI-5640Product features:1.The control sy
Contact Now
Product DescriptionLab Textile Thermal Resistance Tester SKZ175 For the warmth reteining performance (thermal resistance) detection of various fabrics, seam products and insulation materials, using hot plate, by heat-dispersing method.Standards: ISO11092, ASTMD1518, JIS-1096.Features:1. With a computer interface, and test software.2. Measured conductivity coefficient, heat rate, the CLO value. Automatic conversion heat rate, heat transfer coefficient, CLO value.3. Imported temperature sensor, accurate and reliable.4.
Contact Now
Laboratory Pulp Standard Fiber Disintegrator Wet DisintegrationLaboratory Pulp Disintegrator (also known as standard fiber Disintegrator, standard fiber stirrer), Suitable for laboratory wet disintegration of pulp: the disintegration is to separate the interwoven fibersin water after mechanical processing, and meanwhile to maximum remain fiber original structure properties unchanged, in order to ensure the experiment to obtain reliable data, using the original scientific research and production of effective, economy. Standards:ISO5263, JIS-P8220, TAPPI-T205Te
Contact Now
LCD Melt Flow Indexer MRF MVR Meter ISO1133 400degree MFI EquipmentStandards:ISO 1133-1:2011 Plastics — Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics —Part 1:Standard methodISO 1133-2:2011 Plastics — Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics —Part 2: Method for materials sensitive to time temperature history and/or moistureGBT 3682.1-2018 "Plastic Thermoplastic Melt Mass Flow Rate (MFR) and Melt Volume Flow Rate (MVR) Determination"ASTM D1238-2013 "Standard Test Method
Contact Now
DTA Differential Thermal Analyzer SKZ1055Differential thermal analysis: temperature under program control, the relationship and difference of temperature between the measured material and the reference.The DTA curves is to describe the changing relationship depending on temperature and time between the measured material and the reference compound. During the test, the sample temperature changes due to the phase change or an endothermic or exothermic reaction effects.
Contact Now
Microscopic Thermal Analyzer SKZ1040A-1Be used as the melting point of trace samples for determination, but also for biological engineering thermodynamics research in medicine, chemical, synthetic fiber, biology, mineralogy, criminology. Feature1.Using PWM pulse program to control temperature and color touch screen display.2.With 3000 sets of test data storage.3.
Contact Now
STA Synchronous Thermal Analyzer SKZ1060ASimultaneous thermal analysis (DSC/DTA, TGA) is a combination of differential heating and thermo gravimetric . It can not only study the change of sample quality with temperature or time in the process of heating and constant temperature, but also study and analyze the change process of the sample, by the heat generated changes.
Contact Now
SKZ1060 Lab Synchronous Thermal AnalyzerSimultaneous thermal Analyzer STA is a mixture of differential heating and thermo gravimetric .
Contact Now
Laboratory Pulp Disintegrator (also known as standard fiber Disintegrator, standard fiber stirrer), Suitable for laboratory wet disintegration of pulp: the disintegration is to separate the interwoven fibers in water after mechanical processing, and meanwhile to maximum remain fiber original structure properties unchanged, in order to ensure the experiment to obtain reliable data, using the original scientific research and production of effective, economy. Standards:ISO5263, JIS-P8220, TAPPI-T205
Contact Now
SKZ1053 Automatic Thermo Gravimetric Analysis (TGA) Pricing and Features
Thermo gravimetric analysis (TGA) is a technique utilized to monitor the variation in sample quality with respect to temperature or time during the processes of heating and maintaining a constant temperature. Its primary objective is to investigate the thermal stability and composition of materials.
Contact Now
SKZ145 Melt Index Tester Mfi TesterFor engineering plastics such as polycarbonate, nylon, and fluorine plastics, whose melt temperatures are higher, as well as fit for plastics tests of polyethylene, polystyrene, polypropylene, ABS resin, and poly-formaldehyde resin, etc., whose melt temperatures are lower, the following parameters must be determined: melt mass-flow (MFR) (g/10min), melt volume-flow rate (cm3/10min), and the melt density of thermo resin.Standards:ISO 1133-1, ISO 1133-2, GBT 3682.1-2018, ASTM D1238-2013, ASTM D3364-1999 (2011), JJG878-1994, JB/T5456-2016, DIN53735, UNI-5640Char
Contact Now
SKZ1053 High Pressure Automatic Thermogravimetric Analysis LabThermo gravimetric evaluation (TG, TGA) is to look at the exchange of pattern high-quality with temperature or time in the manner of heating and consistent temperature, the motive is to find out about the thermal balance and composition of the material.Widely used in the lookup and development, procedure optimization and satisfactory manipulate of plastics, rubber, coatings, pharmaceuticals, cat
Contact Now
TGA Thermo Gravimetric Analyzer SKZ1053Product descriptionThermo gravimetric analysis (TG, TGA) is to observe the change of sample quality with temperature or time in the process of heating and constant temperature, the purpose is to study the thermal stability and composition of the material. Widely used in the research and development, process optimization and quality control of plastics, rubber, coatings, pharmaceuticals, catalysts, inorganic materials, metal materials and composite materials. Technical parametersTemperature rangeActual maximum temperature 1150℃(S
Contact Now
Digital ViscometerThe viscometer is used to measure the absolute viscosity of Newtonian fluid and non-Newtonian fluids the apparent viscosity, a measure of sensitivity, the test results are reliable, easy to operate, nice shape, can be widely used for oil, paint, plastics, pharmaceuticals, paints, adhesives, detergents, and other fluid viscosity measurements. Features:1. Advanced mechanical design technology, manufacturing technology and microcomputer control technology, accurate data acquisition2. High subdivision drive stepper motor rotation smooth and precise.
Contact Now