For measuring the unvulcanized rubber characteristics to identify the optimum cure time.Feature Imported intelligent digital temperature controller, easy adjust settings, a wide range of temperature control, high control accuracy, stabilityStandard:ASTM D5289, ISO6502, T30,T60,T90.Technical parameters:Temperature rangeroom temperature ~ 300 ℃Warming time≤ 15minTemperature Resolution0 to 200 °C: 0.1 °C0 to 300 °C: 1 °C.Temperature fluctuation≤ ± 0.5 °C (after feeding)Torque range0N.m ~ 10N.mTorque display resolution0.001N.mMaximum test time120min (modify time during testing)Swing angle± 0.5 ° (
Contact Now
SKZ131 ASTM D5289 ISO6502 Rotor-less Curemeter Rubber Vulcanizing Tester-Cure MeterFor measuring the unvulcanized rubber traits to discover the best therapy time.Standard:ASTM D5289, ISO6502, T30,T60,T90.Technical parameters:Temperature rangeroom temperature ~ 300 ℃Warming time≤ 15minTemperature Resolution0 to 200 °C: 0.1 °C0 to 300 °C: 1 °C.Temperature fluctuation≤ ± 0.5 °C (after feeding)Torque range0N.m ~ 10N.mTorque display resolution0.001N.mMaximum test time120min (modify time during testing)Swing angle± 0.5 ° (total amplitude of 1 °)Body swing
Contact Now
SKZ131 Rubber vulcanizing Tester--Rotor-less curemeterFor measuring the unvulcanized rubber characteristics to identify the optimum cure time.Feature Imported intelligent digital temperature controller, easy adjust settings, a wide range of temperature control, high control accuracy, stabilityStandard:ASTM D5289, ISO6502, T30,T60,T90.Technical parameters:Temperature rangeroom temperature ~ 300 ℃Warming time≤ 15minTemperature Resolution0 to 200 °C: 0.1 °C0 to 300 °C: 1 °C.Temperature fluctuation≤ ± 0.5 °C (after feeding)Torque range0N.m ~ 10N.mTorque display resolution0.001N.mMaximum test
Contact Now
SKZ1037C/D High Accuracy Digital Rotatory Auto Viscometer MachineFeatures:1. Advanced mechanical design technology, manufacturing technology and microcomputer control technology, accurate data acquisition2. High subdivision drive stepper motor rotation smooth and precise. Choose white backlit display, high brightness LCD display, the data show clearly3. Can display viscosity, speed, sample liquid temperature, percent, rotor number, and the selection of the rotor speed can be measured current maximum range value4.
Contact Now
Analytical Electronic Balance SKZ-A 1.Using high-precision electromagnetic force balance sensor, more accurate, faster response, less fault.2.Weighing faster, and speed adjusted3. Weight units can be converted4. With counting function5. With Tared, cleared, accumulated, overloaded, under load display, fault alarm6. Built-in RS-232 interface, with the printer, computer connected ParametersModel SKZ-A1004SKZ-A 1104SKZ-A 1204SKZ-A 2004SKZ-A 2104SKZ-A 2204Max.
Contact Now
SKZ2300 4mm 8mm 16mm Portable Spectrophotometer Color Difference Meter 1、Storage●Upon long time no use , cut off external power and remove the battery to avoid damage to the instrument resulting from battery fluid overflow.●Store in a cool, dry environment with a temperature of -20 ° C ~ 50 ° C and a relative humidity of 85% or less.2、Application●Keep the standard whiteboard clean and avoid contamination of the standard whiteboard with stains, dust, etc.●When using the instrument, the ambient temperature is 0 ° C ~ 40 ° C, the relative humidity is 85%, no condensation.●Avoid usi
Contact Now
For the determination folding fatigue strength of the thickness of less than 1mm paper, cardboard and other sheet materials. Using MIT folding method. Color touch-screen display, folding fixture automatically return after each test, statistics of the same group of multiple samples of the data, the maximum, minimum, average and coefficient of variation. ApplicationsFolding Endurance: Under specified conditions, the number of double folding that the test specimen can withstand before breaking indicates the ability of the test specimen to be repeatedly folded.
Contact Now
SR Beating Pulp Tester SKZ115Schopper-Riegler-This instrument is appropriate for checking out a number suspensions with SR much less than 100 ° C.Product Features:1. hydraulic stress shape with stainless steel2. confirms to Standard ISO 3332-1982 and ISO5267/13. filters’s fabric is phosphor bronze, with its working region 100cm2Specifications:Range0-100°SRMinimum scale1°SRTemperature of distilled water20±0.5 ℃Volume of distilled water1000 ml
Contact Now
New Schopper-riegler Beating Pulp Tester SKZ115The instrument is applicable in testing all kinds of suspending pulp liquid that less than 100°SR--- Schopper-Riegler.Standards:QB/T1054-98, GB/T3332-1982 and ISO5267/1.Feature: 1. hydraulic pressure structure with stainless steel 2. confirms to Standard ISO 3332-1982 and ISO5267/13. filters’s material is phosphor bronze, with its working area 100cm2 Technical parameters:Range0-100°SRMinimum scale1°SRTemperature of distilled water20±0.5 ℃Volume of distilled water1000 mlDraining time149±1 sDimension460×250 (mm)Weight 35kg
Contact Now
Used to test the product packaging by the fall of the damage, and assessment of transport handling process, impact resistance, mainly to meet the product packaging to withstand the conditions of transport capacity, so as to improve and perfect the packaging design. Standard: ISO2248, JISZ0202-87 Features:1 single wing drop tester to do free drop test of the package surface, angle, edge, with digital height indicator and height tracking decoder, which can accurately give the product drop height, and the pre-set drop height error of less than 2%, or 10 mm.2 single wing drop test machin
Contact Now
I300F Benchtop Ion MeterSupport for USB or RS-232 communication. Reset feature automatically resumes all settings back to factory default options. IP54 waterproof.PRODUCT SPECIFICATIONSModelI300FParameterspH/ISE/Temp.(mV/pX)pHRange-2.00 to 20.00 pHResolution0.1, 0.01 pHAccuracy±0.01 pHmVRange-2000.0 to 2000.0 mVResolution0.1, 0.01 mVAccuracy±0.1 mV or ±0.03% of reading whichever is greaterpXRange-2.00 to 20.00 pXResolution0.1, 0.01 pXAccuracy±0.01 pXCalibration PointsUp to 5ISERange1.000e-9 to 9.999e+9Unitmol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppbResolutionUp to 4 significant digitsAcc
Contact Now
SKZ102A R457 Brightness Meter Whiteness Tester Laboratory Equipment MachineFunction:1. Test R457 or ISO Brightness2. Analysis if it contains fluorescent whitening agent and determination of reflection fluorescence produced by white fluorescent, that is, degree of whitening3. Test the brightness value of Y10, Ie, the green light diffuse reflectance factor Ry.4. Test non-transparency, transparency, light scattering and light absorption coefficient5. Test the ink absorption value of paper and board. Feature1.
Contact Now
SKZ1052 Differential Scanning Calorimeter (DSC)Performance testing, pleasant control, and polymer lookup all make full-size use of DSC.The purpose is to decide how temperature and warmth glide relate to the internal warmth transition.DSC lookup and improvement encompasses the domains of glass transition temperature,melting point, segment transition, bloodless crystallization, and oxidation induction time (OIT).Features:1.
Contact Now
SKZ1052 Differential Scanning CalorimeterDSC is intended to decide the internal intensity progress connecting with temperature and intensity stream, it is broadly utilized in the field of polymer improvement, execution testing and quality control.
Contact Now
SKZ2600 High Accuracy SpectrophotometerProduct description: SKZ2300/SKZ2600 with competitive price, high quality,high accuracy,easy to operate, easy to understand, affordable and so onSpecificationModelSKZ2300(Single Caliber)SKZ2600(Switchable Caliber)Geometric Conditionsd/8Color SpaceCIEL*a*b*、CIEL*C*h、Hunter LABCIEL*a*b*、CIEL*C*h、CIEL*u*v*、Hunter LAB、CIEXYZ、Yxy、Reflectivity、CMYK、YI Yellowness、Ganz、R457 Whiteness、Taube Whiteness、z Whiteness 、sRGBStandard Light SourceA、D50、D65、F1、F4、 F11(TL84)A、C、D50、D55、D65、D75、F1、F2(CWF)、F3、F4、F5、F6、F7、F8、F9、F10、F11(TL84)、F12(U30)Li
Contact Now
SKZ2054C Portable Gas Detector IP67 Rechargeable Battery H2S Hydrogen Sulfide Gas Meter MonitorSummaryThe apparatus is a dual-purpose suction and diffusion device. The diffusion sampling mode may be automatically selected in the event that the pump malfunctions. Additionally, it has a rear clip for easy carrying. The data log function is used.
Contact Now
FeatureModular internal structure1). Adopting a modular internal structure and obtaining a structural design patent2). It is divided into 3 detection modules, each of which can detect up to 6 gases.3). It can built-in maximum 18 gas detection 4).
Contact Now
SKZ1013 Surface Tension MeasurementThe small design of the automatic surface tensiometer, which consists of a microcomputer control system, a platinum plate (ring) measurement device, and a highly precise and stable force measurement system, makes it easy to operate both manually and automatically.
Contact Now
Wood Moisture Meter SKZ111H-1 Feature:1. Japan advanced sensors, moisture measurements of crude wood, dry plank stuff, a variety of timber products, the measurement range of 0 to 100%.2. Portable smart weighs 200 grams, 160mm, small size, easy to carry, suitable for field use.3. Non-destructive testing: just the probes touch the surface being measured, that is able to display the current moisture content, without damaging the object to be detected.4.
Contact Now
SKZ2054C Multi Gas Analyser CO H2S O2 EX 4 In 1 Gas Smart Meter Detector MachineSummary The SKZ2054C portable gas detector is capable of real-time data display and alert sounding when the measurement gets close to a preset level.The gadget serves as a diffusion and suction device in one. When the pump breaks, it can switch to the diffusion sampling mode automatically. It also features a back clip for the user's convenience when carrying. The data log functionality is available.
Contact Now
SKZ1050E Portable CH4 Gas DetectorThe SKZ1050E is a handheld transportable gasoline detection alarm.
Contact Now
SKZ2054C 4 In 1 Multi Gas Sensor CO H2S O2 EX Gas Detector Monitor With PumpIn briefThe device serves as both a suction and a diffusion tool. If the pump breaks down, the diffusion sampling mode might be chosen automatically. It also features a back clip for convenient carrying. It makes use of the data log function.
Contact Now
M310F-A Multi-parameter AnalyzerPH1.1-5 points calibration with Standard Recognition.2.Selectable pH buffer groups, including NIST, DIN, GB, USA.3.Automatic electrode diagnosis with pH slope and offset display.
Contact Now
SKZ128 Portable Rubber Shore Hardness Testing MachineStandard:ISO7619-1:2004: Rubber, vulcanized or thermoplastic--Determination of indentation hardness-part 1: Duromerer technique ( shore hardness)ISO 868:2003: Plastics and ebonite-Determination of indentation hardness through skill of a duromerer ( shore hardness)Technical parameters:Diameter of pressure needle1.25mm±0.15mmEnd diameter of needle0.79mm±0.03mm (Shore A), R0.1±0.012mm (Shore D)Pressure needle taper angle35°±0.25°Pressure needle trip0- 2.5mm±0.04mmRange of scale0HA-100HA (Shore A), 0-
Contact Now