SKZ1031 Laboratory pulp Dewatering dehydrator Tester MachineThe effect of the centrifugal force of 1400r/min high speed rotation, in the pulp water out and reached a certain degree of dry, in order to ensure the reliable data.
Contact Now
Laboratory pulp dehydratorThe effect of the centrifugal force of 1400r/min high speed rotation, in the pulp water out and reached a certain degree of dry, in order to ensure the reliable data. With the use of beating degree tester, it can obtain accurate pulp beating degree and humidity. Parameters:Drum SizeΦ126X100mmDrum capacity1.2LSpeed1400r/minTiming range01s ~ 999.9sPulp dryness20-30%PowerSingle-phase capacitor motor-180W-220VDimension570 × 225 × 460mmWeight30KG
Contact Now
Laboratory Pulp Disintegrator (also known as standard fiber Disintegrator, standard fiber stirrer), Suitable for laboratory wet disintegration of pulp: the disintegration is to separate the interwoven fibers in water after mechanical processing, and meanwhile to maximum remain fiber original structure properties unchanged, in order to ensure the experiment to obtain reliable data, using the original scientific research and production of effective, economy. Standards:ISO5263, JIS-P8220, TAPPI-T205
Contact Now
SKZ1027A/B/C/D Laboratory Valley Pulp BeaterLaboratory Valley pulp Beater, mechanical forces generated by the roll and the bottom knife, the fiber pulp was cutting, crushing, kneading, split, moistening and fiber thinning, meanwhile, the fiber cell wall displacement and deformation generated, the primary wall and outer wall broken.
Contact Now
Laboratory Pulp AquapulperFunctions:1. Laboratory for virgin pulp or recycled pulp to beating, disintegration and deinking.2. Major laboratory equipment used to process pulp, broke, and waste paper.3. Assessment recycled pulp process, additives and quality 4.
Contact Now
Lab-Potcher is used to simulate the production process of rinsing pulp, can accomplish the process of pulp un-bleached washing, bleaching pulp, pulp bleached process.
Contact Now
New Schopper-riegler Beating Pulp Tester SKZ115The instrument is applicable in testing all kinds of suspending pulp liquid that less than 100°SR--- Schopper-Riegler.Standards:QB/T1054-98, GB/T3332-1982 and ISO5267/1.Feature: 1. hydraulic pressure structure with stainless steel 2. confirms to Standard ISO 3332-1982 and ISO5267/13. filters’s material is phosphor bronze, with its working area 100cm2 Technical parameters:Range0-100°SRMinimum scale1°SRTemperature of distilled water20±0.5 ℃Volume of distilled water1000 mlDraining time149±1 sDimension460×250 (mm)Weight 35kg
Contact Now
Laboratory Pulp Standard Fiber Disintegrator Wet DisintegrationLaboratory Pulp Disintegrator (also known as standard fiber Disintegrator, standard fiber stirrer), Suitable for laboratory wet disintegration of pulp: the disintegration is to separate the interwoven fibersin water after mechanical processing, and meanwhile to maximum remain fiber original structure properties unchanged, in order to ensure the experiment to obtain reliable data, using the original scientific research and production of effective, economy. Standards:ISO5263, JIS-P8220, TAPPI-T205Te
Contact Now
SR Beating Pulp Tester SKZ115Schopper-Riegler-This instrument is appropriate for checking out a number suspensions with SR much less than 100 ° C.Product Features:1. hydraulic stress shape with stainless steel2. confirms to Standard ISO 3332-1982 and ISO5267/13. filters’s fabric is phosphor bronze, with its working region 100cm2Specifications:Range0-100°SRMinimum scale1°SRTemperature of distilled water20±0.5 ℃Volume of distilled water1000 ml
Contact Now
Fiber Classifier (Bauer Fiber Classifier) is the equipment used for measuring the weight-average fiber length of pulp fiber according to screening method by pulp and paper-making laboratory. Principle:Screening the pulp suspension into the vessel, the vessel is charged with mesh sieve, Container into a ladder type, the pulp suspension flows from one container to another container, in various different sieve to retain the fiber length pulp, retention of pulp fiber length and the sieve mesh size.
Contact Now
Vibrating vacuum suction, so that compliant pulp fibers from open screening leak continues, not meet the requirements of fiber and wood residues left in the screen plate above, and then removed from the slag hole.Screening of impurities was measured in the pulp debris impurities, Use the pulp screen machine can reduce the number of impurities in the pulp suspension, get clean good pulp. Features:1. Adopt international standards, stainless steel tube frame, the main components made of stainless steel and copper.2.
Contact Now
Laboratory PFI Beater For beating test of middle and high concentrations pulps, so that to Analysis of high-grade paper. Principle:Placed the pulps, which is measured having a predetermined concentration, between the knife roller and the beating cylinder, rotating with different circumferential speeds. In order to achieve the purpose of beating pulp. Features:1. Main components made of stainless steel,2. Pulp pool with a knife roller are regulated speeds, belt drive,3. The counter can be set to the number of revolutions dissociation pulp,4.
Contact Now
Hand Sheet Former SKZ124BAutomatic type hand sheet former, small dimension more precision and easy to operate, especially get rid of the air-pressure of traditional sheet former. Its sheet diameter Φ200, white water cycle, electromagnetism valve drain automatically, mini-type vacuum system. Main Accessory:copper mesh frame, Paper-making roller, copper mesh 60mesh or 80mesh, up and down water circulative system, air bubble smooth pulp sytem.ParameterCanister diameter200mmCanister capacity 8LPower 463WDimension 500mm×600mm×1300mm
Contact Now
SKZ1030 Laboratory Flotation CellFlotation deinking method is based on the principle of mine ore, according to the fiber, filler and ink composition of wettable, flotation cell in the 10 to 150 micron ink particles adsorbed on the air bubbles, floating to the surface to remove the pulp, fiber and filler remained in the pulp.It is mainly composed of a flotation tank, the circulation line, paper pulp pump, air bubble generating device, liquid discharging pipe. Parameters:Outfall up and down range of activities0 --100Flow calculation controlYes Tank capacity28 litersTank sizeΦ380 × 380mmTank
Contact Now
High Accuracy Brightness Color Meter SKZ102B-1Brightness Meter is widely applied in paper and cardboard, pulp, cotton and fabric, plastic, ceramic and porcelain enamel, amylum, construction material, chemical industry, salt making and other testing department that need to test whiteness, yellowness, color and chromatism, as well as transparency, opacity, light scattering coefficient and light absorption coefficient of paper. Function:1. CIE (1982) whiteness (Ganz visual whiteness) W10 and color shift value Tw10.2.
Contact Now
Digital Brightness Color Meter SKZ102BBrightness Meter is widely applied in paper and cardboard, pulp, cotton and fabric, plastic, ceramic and porcelain enamel, amylum, construction material, chemical industry, salt making and other testing department that need to test whiteness, yellowness, color and chromatism, as well as transparency, opacity, light scattering coefficient and light absorption coefficient of paper. Function:1. Test the color and color difference of reflective objects.2.
Contact Now
Electronic Brightness Meter SKZ102ABrightness Meter is widely applied in paper and cardboard, pulp, cotton and fabric, plastic, ceramic and porcelain enamel, amylum, construction material, chemical industry, salt making and other testing department that need to test whiteness.Function:1. Test R457 or ISO Brightness.2. Analysis if it contains fluorescent whitening agent and determination of reflection fluorescence.produced by white fluorescent, that is, degree of whitening.3. Test the brightness value of Y10, Ie, the green light diffuse reflectance factor Ry.4.
Contact Now
SKZ1016-1 Cap Torque TesterMeasuring bottled products locking and opening torque values. High accuracy, good stability.Features:1. Microcomputer control2. Test data: continuous acquisition or automatically to maintain peak3. Dual-mode design: locking force, opening force4. Test results using the standard unit, without manual conversion5. Intelligent fault indications, overload protection6. Compact, easy to operate, reliable performanceTechnical parameters:Accuracy1gradeSystem Resolution0.01NmClamping rangeΦ15mm ~ Φ160mmMeasuring range0 - 5N.
Contact Now
SKZ1038B Columetrico Karl Fischer TitrationDetermining the trace moisture content of solid, liquid, and gaseous materials using the Columetrico method. widely used in the production of alcohols, oils, fats, ethers, esters, acids, alkanes, benzene, amines, organic solvents, pesticides, phenols, drug raw materials, chemicals, petroleum, pharmaceuticals, and pesticides. Also used in the production of alcohols. Features:1.
Contact Now
KFT-40VC Karl Fischer TitratorFeatureVolumetric Karl Fischer Titration ● Support KF Titration Mode and Titer Detection Mode. ● Features of auto-filling, auto-purging and auto-mixing of the reagents ensure safe handling of Karl Fischer chemicals. ● Automatic/manual background drift correction ensures accurate results. ● Selectable units including mg, mg/L,% , ppm, etc. ● Settable parameters, including measurement unit, polarization current,
stirring rate, titration rate, stop volume, endpoint potential, stop criterion and etc. ● Store up to 20
Contact Now
SKZ104B Paper Bekk Smoothness Tester Testing MachineMain Features1.Imported oil-free vacuum pump2.Fast measurement: with small volume chamber measurement, which measurement time is only one-tenth of a large one, saving time in measurement. And the function of “automatic test" has been added, can greatly save time when testing high smoothness 3.Good seal: adopted foreign vacuum sealed plastic and advanced sealing technology to achieve the national standard requirements;4. Adopted 7.0 inches color touch-screen which makes it easy to operate.5.
Contact Now
PH200EM Benchtop Ph MeterPRODUCT SPECIFICATIONSModelPH200EMParameterspH/mVpHRange-2.000 to 18.000 pHResolution 0.01pHAccuracy±0.01 pHCalibration PointsUp to 3Standard RecognitionNF buffersmV/ORPRange-1999 to 1999 mVResolution1 mVAccuracy±0.1%FSMeasurementReading ModeAuto Read , ContinuousTemp.
Contact Now
TGA Thermo Gravimetric Analyzer SKZ1053Product descriptionThermo gravimetric analysis (TG, TGA) is to observe the change of sample quality with temperature or time in the process of heating and constant temperature, the purpose is to study the thermal stability and composition of the material. Widely used in the research and development, process optimization and quality control of plastics, rubber, coatings, pharmaceuticals, catalysts, inorganic materials, metal materials and composite materials. Technical parametersTemperature rangeActual maximum temperature 1150℃(S
Contact Now
TU4000E Turbidity MeasurementGENERAL FEATURES7” colorful touchscreen.Tungsten lamp light source met USEPA 180.1 requirement.3 photodiodes to ensure high accuracy.1-8 points calibration using Formazin standards or zero water.Autoranging from 0-4000 NTU.Data Storage capacity of 1000 sets (GLP-compliant).
Contact Now