Pressure Differential Scannning Calorimetry-manufacture,factory,supplier from China

(Total 24 Products for Pressure Differential Scannning Calorimetry)
SKZ1052 differential scanning calorimetry dsc analysisPerformance testing, quality control, and polymer research all make extensive use of DSC.The goal is to determine how temperature and heat flow relate to the inner heat transition.DSC research and development encompasses the domains of glass transition temperature,melting point, phase transition, cold crystallization, and ox
Contact Now
SKZ1052 Dsc Differential scanning calorimetry InstrumentsMain Features:1. The industrial-grade 7-inch contact show display screen suggests affluent information.2. Brand-new metal furnace physique structure, with greater baseline and increased accuracy. The heating adopts indirect conduction method, which has immoderate uniformity andstability, reduces pulse radiation, and is greater than general heating mode.3. USB dialog interface, sturdy versatility, reliable and uninterrupted communication, helps self-recovery connection function.4.
Contact Now
SKZ1052 Differential Scanning CalorimeterDSC is intended to decide the internal intensity progress connecting with temperature and intensity stream, it is broadly utilized in the field of polymer improvement, execution testing and quality control.
Contact Now
DSC is widely utilized in the fields of polymer research, performance testing, and quality control. It is intended to identify the inner heat transition in relation to temperature and heat flow. The fields of glass transition temperature, melting point, cold crystallization, phase transition, and oxidation induction time (OIT) are all included in DSC study and development.Standards:ISO/TR10837:1991, ASTM D3895-1998, ASTM E 967, ASTM E 968, ASTM E 793, ASTM D 3895, ASTM D 3417, ASTM D 3418, ISO 11357-6Features: 1. Rich information is shown on an industrial-grade 7-inch touch screen.2.
Contact Now
SKZ1052 Differential Scanning Calorimeter (DSC)Performance testing, pleasant control, and polymer lookup all make full-size use of DSC.The purpose is to decide how temperature and warmth glide relate to the internal warmth transition.DSC lookup and improvement encompasses the domains of glass transition temperature,melting point, segment transition, bloodless crystallization, and oxidation induction time (OIT).Features:1.
Contact Now
SKZ1052 Automatic Pressure Differential Scanning Calorimeter Deutsch For SaleMain Features:1. The industrial-grade 7-inch contact display screen shows prosperous information.2. Brand-new steel furnace physique structure, with higher baseline and greater accuracy. The heating adopts oblique conduction method, which has excessive uniformity andstability, reduces pulse radiation, and is higher than standard heating mode.3.
Contact Now
SKZ1055 Differential Thermal AnalyzerDifferential thermal analysis: temperature under program control, the relationship and difference of temperature between the measured material and the reference.The DTA curves is to describe the changing relationship depending on temperature and time between the measured material and the reference compound. During the test, the sample temperature changes due to the phase change or an endothermic or exothermic reaction effects.
Contact Now
It is applicable in testing the leak capability of soft packaging, semi-rigid package, rigid packaging in food, beverage, pharmacy, etc industry.
Contact Now
SKZ-1052 DSC Test Differential Scanning Calorimeter For LabDSC is designed to decide the internal warmth transition touching on to temperature and heat flow, it is extensively used in the area of polymer development, overall performance trying out & first-rate control.
Contact Now
DSC Differential Scanning Calorimeter SKZ1052Product descriptionDSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control.
Contact Now
SKZ1052C-1L Differential Scanning Calorimeter360° lab and factory: https://skztester.en.alibaba.com/company_profile.html?spm=a2700.shop_oth.8.9DSC Video: https://youtu.be/m9z9fUnwLvg DSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control.
Contact Now
DTA Differential Thermal Analyzer SKZ1055Differential thermal analysis: temperature under program control, the relationship and difference of temperature between the measured material and the reference.The DTA curves is to describe the changing relationship depending on temperature and time between the measured material and the reference compound. During the test, the sample temperature changes due to the phase change or an endothermic or exothermic reaction effects.
Contact Now
Leak Tester is a kind of tester that use compression air to produce negative pressure by vacuum device to test the seal capability and processing technique of soft plastic packaging material in food and pharmaceutical industry. It also can test the specimen which has done the drop and compression test.  Standards GB/T15171-94 (the Seal Testing Method for soft packaging).
Contact Now
Be measured heat sealing temperature range of sealing compound, heat sealing strength, hot package of speed, heat sealing pressure, used for plastic, flexible packaging composite membrane, coated paper, foil.   1. Structure: It contains air drive system, sealing devices, temperature-conditioning systems, time-conditioning systems2. Air-driven system:  Including pressure gauges, guide rods, cylinder, pneumatic valve, pressure regulator handles, so on.
Contact Now
Rubber Vulcanizer SKZ401Rubber Vulcanizer is mainly used for rubber vulcanization, thermosetting plastics and insulation products of pression, This test machine has device of pressure, time, temperature automatic control device, can be realized clamping, regular work cycle, and can automatically pressure compensatingFeatures1.Mainly consists of three parts: the host, hydraulic systems, electrical control system2.It has device of pressure, time, automatic temperature control device, can be clamping, the timing of the work cycle, and can automatically pressure compensatingSpecification 
Contact Now
SKZ1017B Five points Heat Seal TesterStructure:Divided into 4 components of the air power system, warmness sealing device, temperature manage system, time-conditioning systems.1. Structure: It contains air drive system, sealing devices, temperature-conditioning systems, time-conditioning systems2. Air-driven system:  Including pressure gauges, guide rods, cylinder, pneumatic valve, pressure regulator handles, so on.
Contact Now
SKZ1013 Automatic Interfacial Tensiometer PriceAutomatic floor tensiometer, made up of excessive specific and secure pressure dimension system, microcomputer manage system, platinum plate (ring) size device, is compact in design, easy and dependable in structure, handy in operation (automatic/manual). It elements internet weight in complete vary (one-key minimal clearing), total vary automated calibration, right repeatability, correct and dependable take a look at end result as nicely as liquid crystal show of check statistics with RS232C output interface.Features:1.
Contact Now
Auto Pneumatic Bursting Strength TesterDetermination pressure for a variety of fabrics, including knits, woven fabric, non-woven fabric, laminated fabric and other craft-made variety of fabrics, in standard conditions or under wet bursting strength and bursting dilation. Standards ISO13938-2, ASTM D3786, IWS Tm29Test principleThrough the circular clamping the sample holder can be extended in the diaphragm, the gas pressure applied below the diaphragm, the diaphragm and the sample expansion.
Contact Now
SKZ1050 Combustion Analyzer TVOC Total Organic Volatiles Gas Measurement VOC Detector Function1.The gas concentration compensation works in conjunction with temperature and pressure adjustment to create the ideal, varied temperature and pressure environment.2.Two alarm points with light and sound, each with customisable settings.3. A large-capacity rechargeable lithium polymer battery.4.
Contact Now
SKZ1060 Lab Synchronous Thermal AnalyzerSimultaneous thermal Analyzer STA  is a mixture of differential heating and thermo gravimetric .
Contact Now
The Auto-pneumatic Cutter Press is driven by air pressure only. lt is suitable for laboratory to punch every kind of standard specimens from rubber, plastic, leather Standard: ASTM-D412Technical parameters:TypesPNEUMATICMoving distance25mm~100mmWorking platform320 mm×220 mmSpecimen thicknessmaximum 10mmAir pressure0.6MPaDimension380mm×260mm×590mmNet weight40kg
Contact Now
SKZ128 Portable Rubber Shore Hardness Testing MachineStandard:ISO7619-1:2004: Rubber, vulcanized or thermoplastic--Determination of indentation hardness-part 1: Duromerer technique ( shore hardness)ISO 868:2003: Plastics and ebonite-Determination of indentation hardness through skill of a duromerer ( shore hardness)Technical parameters:Diameter of pressure needle1.25mm±0.15mmEnd diameter of needle0.79mm±0.03mm (Shore A), R0.1±0.012mm (Shore D)Pressure needle taper angle35°±0.25°Pressure needle trip0- 2.5mm±0.04mmRange of scale0HA-100HA (Shore A), 0-
Contact Now
Air Permeability Tester For Paper SKZ119 The tester is designed to assess the moderate air permeability of paper within the range of 0 to 17μm (Pa.S), in accordance with the ISO 5636-2:1984 standardfor determining air permeance using the Schopper method.SpecificationTesting range0-17μm/(Pa.S)Pressure area10.0±0.05cm²Pressure error1.00±0.01kPaSample size60×100 (mm)Dimension350×250×1160 (mm)Weight21.5kgConstant pressure difference is 1Kpa    Airflow (ml/s) Test lasting time (S)   Measured volume (ml)   0.13—0.33  &nb
Contact Now
Hand Sheet Former SKZ124BAutomatic type hand sheet former, small dimension more precision and easy to operate, especially get rid of the air-pressure of traditional sheet former. Its sheet diameter Φ200, white water cycle, electromagnetism valve drain automatically, mini-type vacuum system. Main Accessory:copper mesh frame, Paper-making roller, copper mesh 60mesh or 80mesh, up and down water circulative system, air bubble smooth pulp sytem.ParameterCanister diameter200mmCanister capacity 8LPower 463WDimension 500mm×600mm×1300mm
Contact Now
Relate News
SKZ1052 high-precision differential scanning calorimeter is an instrument launched by SKZ for conducting material thermal analysis experiments. It can be used to test oxidation induction period, glass transition temperature, melting point, melting, enthalpy change, phase change, cold crystallization, crystallization, product stability, curing degree, cross-linking degree, specific heat capacity, reaction heat, etc. The instrument uses imported sensors with high sensitivity. Signal acquisition circuit shielding protection, strong anti-interference, and high baseline stability.
SKZ401 Rubber Vulcanizer is mainly used for vulcanizing flat type tape (such as conveyor belt, transmission belt, referred to as flat belt), belongs to hydraulic machinery, the main function of plate vulcanizing machine is to provide the pressure and temperature required for vulcanization. The pressure is generated by the hydraulic system through the hydraulic cylinder, and the temperature is provided by the heating medium (usually steam, thermal oil, etc., and superhot water is also useful).
Minimeta is a maintenance-free single gas detector that is the most reliable, user-friendly and cost-effective inspection solution for ensuring worker safety and operational compliance. It provides protection for up to 2 years - no calibration, no sensor replacement, no battery replacement or battery charging.
Our company is specialized in manufacturing and supply Lab equipment: Scientific instrument, Analytical Instrument, Thermal Analysis, Moisture meter, Gas detector and testing instruments for pulps, paper, cardboards, plastic, rubber and textile. Our moisture meters and gas detectors obtained CE certification and professional test report in August 2021. We have original trademarks on July 19,2018 and intellectual property certificates on Decmeber 12,2018.
SKZ111B-4 Microcomputer rice polisher can complete the whole process of rice husking and brown rice grinding through automatic one time, which can quickly and truly judge the quality of rice. SKZ111B-4 Microcomputer rice polisher has the advantages of simple operation, good white effect, short working time, strong and wear-resistant head, beautiful appearance and so on.
The principle of SKZ1062A wet method laser particle size analyzer is to measure the particle size distribution of particles in solid powder or emulsion.
SKZ111 paper carton moisture meter is a high-performance digital moisture measuring instrument introduced by our company in the domestic market with foreign advanced technology. The instrument adopts the principle of high frequency wave, the digital display, the sensor and the main body are integrated into one, and there are 6 gears used to measure the moisture of various paper, cardboard, tile paper, carton, pulp board, etc.
Our SKZ111B-1 grain moisture meter is a portable and easy-to-use device that can accurately measure the moisture content of 33 different types of grains including coffee beans. It supports English language and comes with CE and ISO9001 certifications, ensuring the quality and safety of the product.This grain moisture meter is designed with convenience in mind. It is light in weight, compact, and easy to carry around, making it ideal for on-site measurements.
Laboratory pH meter (acidity meter) is an electrochemical analytical instrument used to measure the pH value of aqueous solutions. The pH meter adopts the potentiometric method, and the main measuring components are the reference electrode and glass electrode. The reference electrode is stable, while the glass electrode is sensitive.
Carbon black content tester is an instrument used to measure carbon black content in materials.The basic principle of the carbon black content tester is to quantitatively analyze the carbon black in the material by burning the carbon black in the sample in the oxygen environment.Method of applicationTo use the carbon black content tester, follow the following steps:Prepare the sample: Put 1g sample to be tested and put it into the combustion boat according to the test.Preheating: Turn on the tester, pass nitrogen for a few minutes, and set the temperature program.Place the sample: Place the pr
x

Submitted successfully

We will contact you as soon as possible

Close