SKZ132 Mooney ViscometerUsed to calculate the viscosity, scorch, and curing index of raw rubber or rubber compound1. Data display, computer control, and automatic calibration2. Wide temperature range and easily adjustable settings on an imported digital temperature controller3. Making use of the most recent "host + computer + printer" framework concepts Standards: ASTM D1646,ISO 289,JIS K6300,GB/T 1232,GB/T 1233A Control Software Feature is:1. The options' units are kgf-cm, lbf-in Nm, dN-m, and MV;2.
Contact Now
SKZ132 GB/T 1232 GB/T 1233 Raw rubber or rubber Mooney ViscometerUsed to Raw rubber or rubber compound for the determination of Viscosity, scorch and curing indexStandardsASTM D1646,ISO 289,JIS K6300,GB/T 1232,GB/T 1233Feature of Control Software: 1. Unit of options: kgf-cm, lbf-in Nm, the dN-m, the MV;2. Test data: contains the Mooney viscosity, scorch various data;3. Test curve: Mooney viscosity curve, Mooney scorch curve, temperature curve of the upper and lower mold4. Modify the time during testing5. The test data can be saved automatically6.
Contact Now
Used to Raw rubber or rubber compound for the determination of Viscosity, scorch and curing index StandardsASTM D1646,ISO 289,JIS K6300,GB/T 1232,GB/T 1233 Feature of host 1. Computer control, Data display, Automatic calibration2. Imported digital temperature controller, easy to adjust settings, wide temperature range3. Using the latest principles of a "host + computer + printer" structureFeature of Control Software: 1. Unit of options: kgf-cm, lbf-in Nm, the dN-m, the MV;2. Test data: contains the Mooney viscosity, scorch various data;3.
Contact Now
NTV-AI High temperature ViscometerThe viscometer is used to measure the absolute viscosity of Newtonian fluid and non-Newtonian fluids the apparent viscosity, a measure of sensitivity, the test results are reliable, easy to operate, nice shape, can be widely used for Hot melt adhesive, asphalt, paraffin waxFeatures:1. The 7-inch large intelligent touch operation, the operation is simple and convenient, and it can display the dynamic viscosity value, the kinematic viscosity value, and the viscosity-temperature curve.2.
Contact Now
Digital ViscometerThe viscometer is used to measure the absolute viscosity of Newtonian fluid and non-Newtonian fluids the apparent viscosity, a measure of sensitivity, the test results are reliable, easy to operate, nice shape, can be widely used for oil, paint, plastics, pharmaceuticals, paints, adhesives, detergents, and other fluid viscosity measurements. Features:1. Advanced mechanical design technology, manufacturing technology and microcomputer control technology, accurate data acquisition2. High subdivision drive stepper motor rotation smooth and precise.
Contact Now
Digital Density Balance for Emulsions Chemical Solution SKZ300EApplicationsDirect readings, with temperature compensation, and Solution compensation, more humanized operation, suitable for onsite operations.For density determination of Chemical solution, additives, suspensions, emulsions, dispersions, homogeneous type solution, mouthwash, pharmaceutical, and other high viscosity, suspensions, emulsions, colloidal liquid Features1.Direct reading density of liquid, which density> 1 or <12.
Contact Now
SKZ1037C/D High Accuracy Digital Rotatory Auto Viscometer MachineFeatures:1. Advanced mechanical design technology, manufacturing technology and microcomputer control technology, accurate data acquisition2. High subdivision drive stepper motor rotation smooth and precise. Choose white backlit display, high brightness LCD display, the data show clearly3. Can display viscosity, speed, sample liquid temperature, percent, rotor number, and the selection of the rotor speed can be measured current maximum range value4.
Contact Now
SKZ144 Vicat Softening Temperature Tester Used to measure polymer materials' Vicat softening and heat distortion temperatures. Feature 1.Setting the temperature with a temperature controller and measuring distortion with a meter.2.The specimen stand has an automated up/down motion and can test three specimens simultaneously.Standard:ASTM-D1525, ASTM-D648, DIN53460,DIN53461,ISO-306,ISO-75Technical parameters: Temperature rangeroom temperature~350℃Heating speed(12±1)oC/6min[(120±10)oC/h](5±0.5)oC/6min[(50±5)oC/h]Max temperature error±0.1℃Measuring range of distortion0-1mmMeasu
Contact Now
The sample cutter for Cobb absorbency testing.Technical parameters:Specimen thickness0.1-1.0(mm)Error±0.2mmSpecimen diameter125mmDimension 240×288×435(mm)Weight28Kg
Contact Now
Product IntroductionNitrogen can be used to fill granaries and prevent food from rotting. Nitrogen can also be used for various industrial purposes. Our SKZ1050 nitrogen detector can detect nitrogen in nitrogen tanks and also in grain silos, with a typical range of 0-100% VOLApplication1. Furniture, flooring, wallpaper, paint, gardening, indoors ornament and renovation, dyes, paper, pharmaceutical, medical, food, corrosion2.
Contact Now
Designed according to GB/T1540-1989, ISO535 (Cobb paper and cardboard absorbency method), which is used to test the absorbency of paper and cardboard, but not applied to evaluate the writing capability of paper and cardboard.Technical parameters:Metal cylinder inside area100±0.2cm², height: 50mmAbsorbency paper200~250g/m²Absorbency speed75mm/10minSmooth metal rollerwidth:200±0.5mm, weight:10±0.5kgDimension390×280×410 (mm)Weight 25kgOptional Balance: accuracy 0.001g, measure range 500gStopwatch: 1sGlass graduate: 100ml Cobb sample cutter
Contact Now
Used for testing the stiffness of all kinds of woven and knit goods, nonwoven fabrics and coated fabrics, including cotton, wool, silk, linen and chemical fiber, and also of flexible materials such as paper, leather, filmRelevant Standards:ZB WO4003, ISO 9073, ASTM D 1388, ISO9073-7, BS En22313Warranty1 yearCustomized supportOEMPlace of OriginChinaShandongBrand NameSKZWorking patternMicro-computer controlled, infrared stealth slant detecting, liquid crystal display, printing out testing resultsTesting range40.5, 43, 45( adjustable)Extension elongation0.5-20.5cmTesting accuracy0.01 cmSpecimen s
Contact Now
SKZ1016-1 Cap Torque TesterMeasuring bottled products locking and opening torque values. High accuracy, good stability.Features:1. Microcomputer control2. Test data: continuous acquisition or automatically to maintain peak3. Dual-mode design: locking force, opening force4. Test results using the standard unit, without manual conversion5. Intelligent fault indications, overload protection6. Compact, easy to operate, reliable performanceTechnical parameters:Accuracy1gradeSystem Resolution0.01NmClamping rangeΦ15mm ~ Φ160mmMeasuring range0 - 5N.
Contact Now
SKZ2600 High Accuracy SpectrophotometerProduct description: SKZ2300/SKZ2600 with competitive price, high quality,high accuracy,easy to operate, easy to understand, affordable and so onSpecificationModelSKZ2300(Single Caliber)SKZ2600(Switchable Caliber)Geometric Conditionsd/8Color SpaceCIEL*a*b*、CIEL*C*h、Hunter LABCIEL*a*b*、CIEL*C*h、CIEL*u*v*、Hunter LAB、CIEXYZ、Yxy、Reflectivity、CMYK、YI Yellowness、Ganz、R457 Whiteness、Taube Whiteness、z Whiteness 、sRGBStandard Light SourceA、D50、D65、F1、F4、 F11(TL84)A、C、D50、D55、D65、D75、F1、F2(CWF)、F3、F4、F5、F6、F7、F8、F9、F10、F11(TL84)、F12(U30)Li
Contact Now
SKZ131 Rubber vulcanizing Tester--Rotor-less curemeterFor measuring the unvulcanized rubber characteristics to identify the optimum cure time.Feature Imported intelligent digital temperature controller, easy adjust settings, a wide range of temperature control, high control accuracy, stabilityStandard:ASTM D5289, ISO6502, T30,T60,T90.Technical parameters:Temperature rangeroom temperature ~ 300 ℃Warming time≤ 15minTemperature Resolution0 to 200 °C: 0.1 °C0 to 300 °C: 1 °C.Temperature fluctuation≤ ± 0.5 °C (after feeding)Torque range0N.m ~ 10N.mTorque display resolution0.001N.mMaximum test
Contact Now
ISO 132 133 rubber fatigue (Flex) cracking machineFeatureThe host and controller feature digital settings, LED displays for flexible timing, and automatic stand functionality.Secure the specimen individually in the clamp.
Contact Now
SKZ134 Rubber PlastometerUsed to test plastic value and restoration value of raw rubber, plastic rubber and rubber. It takes high accurate temperature control and time instrument with digital setting, temperature and time display.Standard:GB/T12828 and ISO7323-1985.SpecificationSpecimen suffered pressure49N±0.05NTemperature control70℃±1℃ (optionally set in the range of 100℃)Time range 3minIndicating range0-30 (mm)Indicating accuracy0.01mmPower 220V, 50HZ, 700WDimension 360×280×570 (mm)Net weight35kg
Contact Now
SKZ131 ASTM D5289 ISO6502 Rotor-less Curemeter Rubber Vulcanizing Tester-Cure MeterFor measuring the unvulcanized rubber traits to discover the best therapy time.Standard:ASTM D5289, ISO6502, T30,T60,T90.Technical parameters:Temperature rangeroom temperature ~ 300 ℃Warming time≤ 15minTemperature Resolution0 to 200 °C: 0.1 °C0 to 300 °C: 1 °C.Temperature fluctuation≤ ± 0.5 °C (after feeding)Torque range0N.m ~ 10N.mTorque display resolution0.001N.mMaximum test time120min (modify time during testing)Swing angle± 0.5 ° (total amplitude of 1 °)Body swing
Contact Now
For measuring the unvulcanized rubber characteristics to identify the optimum cure time.Feature Imported intelligent digital temperature controller, easy adjust settings, a wide range of temperature control, high control accuracy, stabilityStandard:ASTM D5289, ISO6502, T30,T60,T90.Technical parameters:Temperature rangeroom temperature ~ 300 ℃Warming time≤ 15minTemperature Resolution0 to 200 °C: 0.1 °C0 to 300 °C: 1 °C.Temperature fluctuation≤ ± 0.5 °C (after feeding)Torque range0N.m ~ 10N.mTorque display resolution0.001N.mMaximum test time120min (modify time during testing)Swing angle± 0.5 ° (
Contact Now
SKZ145A Melt Flow Indexer PlastometerTechnical parameters:Test methodMFR (unit: g / 10min)Temperature rangeroom temperature ~ 300 ℃Temperature accuracy± 0.5 ℃Temperature Resolution0.1 ℃Measuring range0.1 ~ 300g / 10min (MFR)load3.187 ~ 211.82N is divided into eightBarrel diameterф9.55mm ± 0.025mmDie apertureΦ2.095 ± 0.005mmPowerAC220V±10% 50Hz 1kWDimension300mm×400mm×500mmWeight35kg ABOUT USSKZ Industrial Co., Limited and SKZ International Co., Limited are the individuals of SKZ, which are specialised in furnish rubber trying out machine.SKZ&n
Contact Now
SKZ145A Melt Flow Indexer MFR instrumentTechnical parameters:Test methodMFR (unit: g / 10min)Temperature rangeroom temperature ~ 300 ℃Temperature accuracy± 0.5 ℃Temperature Resolution0.1 ℃Measuring range0.1 ~ 300g / 10min (MFR)load3.187 ~ 211.82N is divided into eightBarrel diameterф9.55mm ± 0.025mmDie apertureΦ2.095 ± 0.005mmPowerAC220V±10% 50Hz 1kWDimension300mm×400mm×500mmWeight35kg ABOUT USSKZ Industrial Co., Limited and SKZ International Co., Limited are the humans of SKZ, which are specialised in furnish rubber attempting out machine.SKZ installed 
Contact Now
Standard: ISO1133 Feature:1. LCD display, time, temperature and sample times can be set.2. Built-in printer 3. Automatic cutting4. MFR test item Technical parameters:Test methodMFR (unit: g / 10min)Temperature rangeroom temperature ~ 300 ℃Temperature accuracy± 0.5 ℃Temperature Resolution0.1 ℃Measuring range0.1 ~ 300g / 10min (MFR)load3.187 ~ 211.82N is divided into eightBarrel diameterф9.55mm ± 0.025mmDie apertureΦ2.095 ± 0.005mmPowerAC220V±10% 50Hz 1kWDimension300mm×400mm×500mmWeight 35kg
Contact Now
Portable Handheld Hay Moisture Tester HygrometerFeature Using high-frequency principle, frequency more than 10MHZSensor probe is 316L steel + PTFE, it is corrosion, wear resistantWith 10th measurement switch stalls.
Contact Now
SKZ-SY3020/3060 Handheld SpectrophotometerSpecificationModelSKZ3020-Basic versionSKZ3060-Professional versionCaliberSingle Caliber 4mm or 8mmSwitchable caliber 4mm and 8mmSCI SCESCISCI and SCELight typeHigh accuracy full spectrum LEDHigh accuracy full spectrum LED+Dual UVFix positionVisualCamera locationRepeated Accuracy△E≤0.07△E≤0.03Color spaceCIE-Lab, CIE-LCh, Luv, Hunter-Lab, XYZ, Yxy, sRGB, DIN LAB99, CMYK (A/T/E/M/I) Field density, Munsell, Reflectance (bright vision), Blackness, YI yellow, Isochromatic spectrum (light jumping), hiding power, tint/strength/dye
Contact Now