SKZ145 Melt Index Tester Mfi TesterFor engineering plastics such as polycarbonate, nylon, and fluorine plastics, whose melt temperatures are higher, as well as fit for plastics tests of polyethylene, polystyrene, polypropylene, ABS resin, and poly-formaldehyde resin, etc., whose melt temperatures are lower, the following parameters must be determined: melt mass-flow (MFR) (g/10min), melt volume-flow rate (cm3/10min), and the melt density of thermo resin.Standards:ISO 1133-1, ISO 1133-2, GBT 3682.1-2018, ASTM D1238-2013, ASTM D3364-1999 (2011), JJG878-1994, JB/T5456-2016, DIN53735, UNI-5640Char
Contact Now
LCD Melt Flow Indexer MRF MVR Meter ISO1133 400degree MFI EquipmentStandards:ISO 1133-1:2011 Plastics — Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics —Part 1:Standard methodISO 1133-2:2011 Plastics — Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics —Part 2: Method for materials sensitive to time temperature history and/or moistureGBT 3682.1-2018 "Plastic Thermoplastic Melt Mass Flow Rate (MFR) and Melt Volume Flow Rate (MVR) Determination"ASTM D1238-2013 "Standard Test Method
Contact Now
SKZ145 Melt Flow Rate TesterMelt mass-flow (MFR) (g/10min), melt volume-flow rate (cm3/10min), and the melt density of thermo resin must be determined for engineering plastics, which have higher melt temperatures, such as polycarbonate, nylon, and fluorine plastics; and for fit for plastics tests, which have lower melt temperatures, such as polyethylene, polystyrene, polypropylene, ABS resin, and poly-formaldehyde resin, etc.Standards:ISO 1133-1, ISO 1133-2, GBT 3682.1-2018, ASTM D1238-2013, ASTM D3364-1999 (2011), JJG878-1994, JB/T5456-2016, DIN53735, UNI-5640Product features:1.The control sy
Contact Now
To determine the melt mass-flow MFR (g/10min), the melt volume-flow rate MFV(cm3/10min) and the melt density of thermo resin, for the engineering plastics of polycarbonate, nylon and fluorine plastics, whose melt temperature are higher, but also fit for the plastics tests of polyethylene, polystyrene, polypropylene, ABS resin and poly-formaldehyde resin, etc, whose melt temperature are lower, widely applied to the fields of plastics materials, product, petrochemical.Standards:ISO 1133-1:2011 Plastics — Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplas
Contact Now
SKZ145A Melt Flow Indexer PlastometerTechnical parameters:Test methodMFR (unit: g / 10min)Temperature rangeroom temperature ~ 300 ℃Temperature accuracy± 0.5 ℃Temperature Resolution0.1 ℃Measuring range0.1 ~ 300g / 10min (MFR)load3.187 ~ 211.82N is divided into eightBarrel diameterф9.55mm ± 0.025mmDie apertureΦ2.095 ± 0.005mmPowerAC220V±10% 50Hz 1kWDimension300mm×400mm×500mmWeight35kg ABOUT USSKZ Industrial Co., Limited and SKZ International Co., Limited are the individuals of SKZ, which are specialised in furnish rubber trying out machine.SKZ&n
Contact Now
SKZ145A Melt Flow Indexer MFR instrumentTechnical parameters:Test methodMFR (unit: g / 10min)Temperature rangeroom temperature ~ 300 ℃Temperature accuracy± 0.5 ℃Temperature Resolution0.1 ℃Measuring range0.1 ~ 300g / 10min (MFR)load3.187 ~ 211.82N is divided into eightBarrel diameterф9.55mm ± 0.025mmDie apertureΦ2.095 ± 0.005mmPowerAC220V±10% 50Hz 1kWDimension300mm×400mm×500mmWeight35kg ABOUT USSKZ Industrial Co., Limited and SKZ International Co., Limited are the humans of SKZ, which are specialised in furnish rubber attempting out machine.SKZ installed 
Contact Now
Standard: ISO1133 Feature:1. LCD display, time, temperature and sample times can be set.2. Built-in printer 3. Automatic cutting4. MFR test item Technical parameters:Test methodMFR (unit: g / 10min)Temperature rangeroom temperature ~ 300 ℃Temperature accuracy± 0.5 ℃Temperature Resolution0.1 ℃Measuring range0.1 ~ 300g / 10min (MFR)load3.187 ~ 211.82N is divided into eightBarrel diameterф9.55mm ± 0.025mmDie apertureΦ2.095 ± 0.005mmPowerAC220V±10% 50Hz 1kWDimension300mm×400mm×500mmWeight 35kg
Contact Now
SKZ132 Mooney ViscometerUsed to calculate the viscosity, scorch, and curing index of raw rubber or rubber compound1. Data display, computer control, and automatic calibration2. Wide temperature range and easily adjustable settings on an imported digital temperature controller3. Making use of the most recent "host + computer + printer" framework concepts Standards: ASTM D1646,ISO 289,JIS K6300,GB/T 1232,GB/T 1233A Control Software Feature is:1. The options' units are kgf-cm, lbf-in Nm, dN-m, and MV;2.
Contact Now
NTV-AI High temperature ViscometerThe viscometer is used to measure the absolute viscosity of Newtonian fluid and non-Newtonian fluids the apparent viscosity, a measure of sensitivity, the test results are reliable, easy to operate, nice shape, can be widely used for Hot melt adhesive, asphalt, paraffin waxFeatures:1. The 7-inch large intelligent touch operation, the operation is simple and convenient, and it can display the dynamic viscosity value, the kinematic viscosity value, and the viscosity-temperature curve.2.
Contact Now
Thermostatic Abbe Refractometer SKZ1019CTo measure transparent and translucent liquid: refractive index nD and sugar content (Brix), the mass fraction of glucose syrup, F42, F55, juice, vegetables, soft drinks and canned goods dry matter content Features: 1.Color touch screen interface2.Automatic measurement, test speed, repeatability, used high resolution line array CCD image sensor makes it achieved automatically measurement and automatically displayed3.Used glow diode (LED) as light, improve the precision, FPGA technology realize high-speed data signal acquisition is
Contact Now
SKZ145 ISO1133 Manufacture Auto LCD Melt Flow Indexer Factory Melt Flow IndexerStandards:ISO 1133-1:2011 Plastics — Determination of the soften mass-flow price (MFR) and soften volume-flow price (MVR) of thermoplastics —Part 1:Standard methodISO 1133-2:2011 Plastics — Determination of the soften mass-flow charge (MFR) and soften volume-flow charge (MVR) of thermoplastics —Part 2: Method for substances touchy to time temperature records and/or moistureASTM D1238-2013 "Standard Test Meth
Contact Now
ABBE Digital Refractometer SKZ1019AABBE Digital Refractometer, Automatic correction of the effect of temperature on the Brix. Visual aim Feature1. Measurement of refractive index nD of transparent or translucent liquid and solid substances.2. Measurement of the Brix of sugar solution. 3. Visual aim and LCD display 4. Automatic correction of the effect of temperature on the Brix.5.
Contact Now
SKZ1043 Automatic Potentiometric TitratorUsed for the detection of index with plausible ability analysis, can be used as extraordinary instrument for the detection of penicillin, by means of measuring the alternate in electrode potential, to measure the ion concentration, extensively used for the pharmaceutical industry, meals industry, petrochemical industry, metallurgy, environmental protection, electroplating substances industry.Main functions1.Titration type of chemical reaction: acid-base titration, redox titration
Contact Now
Automatic Potentiometric Titrator Used for the detection of index with potential capacity analysis, can be used as special instrument for the detection of penicillin, by measuring the change in electrode potential, to measure the ion concentration, widely used for the pharmaceutical industry, food industry, petrochemical industry, metallurgy, environmental protection, electroplating materials industry. Main functions1.Titration type of chemical reaction: acid-base titration, redox titration, complexometric titration and precipitation titration.2.
Contact Now
Automatic Potentiometric Titrator SKZ1043Used for the detection of index with potential capacity analysis, can be used as special instrument for the detection of penicillin, by measuring the change in electrode potential, to measure the ion concentration, widely used for the pharmaceutical industry, food industry, petrochemical industry, metallurgy, environmental protection, electroplating materials industry. Main functions1.Titration type of chemical reaction: acid-base titration, redox titration, complexometric titration and precipitation titration.2.
Contact Now
Used to Raw rubber or rubber compound for the determination of Viscosity, scorch and curing index StandardsASTM D1646,ISO 289,JIS K6300,GB/T 1232,GB/T 1233 Feature of host 1. Computer control, Data display, Automatic calibration2. Imported digital temperature controller, easy to adjust settings, wide temperature range3. Using the latest principles of a "host + computer + printer" structureFeature of Control Software: 1. Unit of options: kgf-cm, lbf-in Nm, the dN-m, the MV;2. Test data: contains the Mooney viscosity, scorch various data;3.
Contact Now
Ink Absorption Tester SKZ308Ink absorbency tester is the determination of paper or cardboard in a specific time and area to absorb standard ink performance. Technical parameter:Speed15.5 ± 1.0cm / minInking platen opening area20 ± 0.4cm2Inking platen thickness0.1mmInk absorption timeAutomatic control120 ± 5sPower220V ± 10% 50Hz, 90WDimensions530 × 318 × 276mmWeight33Kg
Contact Now
SR Beating Pulp Tester SKZ115Schopper-Riegler-This instrument is appropriate for checking out a number suspensions with SR much less than 100 ° C.Product Features:1. hydraulic stress shape with stainless steel2. confirms to Standard ISO 3332-1982 and ISO5267/13. filters’s fabric is phosphor bronze, with its working region 100cm2Specifications:Range0-100°SRMinimum scale1°SRTemperature of distilled water20±0.5 ℃Volume of distilled water1000 ml
Contact Now
IGT Printability Tester SKZ1032Printability Tester is a most basic designed for paper and paperboard printing picking printability test development of computer process control apparatus. Applicable to all kinds of offset, letterpress and gravure paper and cardboard printing simulation test. Equipped with a high speed ink refilling equipment, a standard scale, aluminum printing plates, wrapping paper.StandardsISO3782, GB/T2679.15, QB/T1058,TAPPI 514 and 575, SCAN P 63:90 Feature: ① the control system accurate.
Contact Now
Lab Vibration Tester SKZ126AThis tester is applicable to toys, electronics, furniture, gifts, ceramics, packaging and other products to simulate transport tests, accords with the U.S.
Contact Now
SKZ129B DIN Abrasion Tester DIN AbraderStandardISO4649, DIN 53516Technical parameters:Sample load2.5N, 5N,10NStroke40m or 20mRoller speed40 ± 1r/minRoller diameterФ150 ± 0.2mmRoller length460mmSample dia.Ф16 ± 0.2mmPowerAC220V ± 10% 50HzDimension700mm × 340mm × 300mmWeight63kgEXCELLENT PERFORMANCE,SUPERB TECHNOLOGYStainless steel rollerAnti-corrosion and anti-rustThe operation interface is simple and clearStandard: lS04649, DIN 53516PRODUCT DISPLAYSKZ129B is suitable for wear testing ofelastic materials, rubbertires, conveyor belts, soles, soft synthetic leather, leather andother materials, wi
Contact Now
SKZ1017B Five point heat sealing apparatusThe Five-point heat-seal Tester, also known as the gradient heat seal tester, is a versatile tool used to determine various parameters related to heat sealing. It can be used to determine the heat sealing temperature range, suitable packaging speed, and heat sealing pressure of different materials such as plastic film substrates, flexible packaging composite films, coated paper, and other heat sealing composite membranes.
Contact Now
Schopper-Riegler Beating Freeness Tester MachineStandards:QB/T1054-98, GB/T3332-1982 and ISO5267/1.Feature:1. hydraulic pressure structure with stainless steel2. confirms to Standard ISO 3332-1982 and ISO5267/13.
Contact Now
SKZ128A Durometer Hardness Tester For RubberA shore hardness tester is used to determine the hardness of vulcanized rubber and plastic.The hardness head has been mounted on the stand.
Contact Now