LCD Melt Flow Indexer MRF MVR Meter ISO1133 400degree MFI EquipmentStandards:ISO 1133-1:2011 Plastics — Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics —Part 1:Standard methodISO 1133-2:2011 Plastics — Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics —Part 2: Method for materials sensitive to time temperature history and/or moistureGBT 3682.1-2018 "Plastic Thermoplastic Melt Mass Flow Rate (MFR) and Melt Volume Flow Rate (MVR) Determination"ASTM D1238-2013 "Standard Test Method
Contact Now
SKZ145 Melt Flow Rate TesterMelt mass-flow (MFR) (g/10min), melt volume-flow rate (cm3/10min), and the melt density of thermo resin must be determined for engineering plastics, which have higher melt temperatures, such as polycarbonate, nylon, and fluorine plastics; and for fit for plastics tests, which have lower melt temperatures, such as polyethylene, polystyrene, polypropylene, ABS resin, and poly-formaldehyde resin, etc.Standards:ISO 1133-1, ISO 1133-2, GBT 3682.1-2018, ASTM D1238-2013, ASTM D3364-1999 (2011), JJG878-1994, JB/T5456-2016, DIN53735, UNI-5640Product features:1.The control sy
Contact Now
To determine the melt mass-flow MFR (g/10min), the melt volume-flow rate MFV(cm3/10min) and the melt density of thermo resin, for the engineering plastics of polycarbonate, nylon and fluorine plastics, whose melt temperature are higher, but also fit for the plastics tests of polyethylene, polystyrene, polypropylene, ABS resin and poly-formaldehyde resin, etc, whose melt temperature are lower, widely applied to the fields of plastics materials, product, petrochemical.Standards:ISO 1133-1:2011 Plastics — Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplas
Contact Now
SKZ145A Melt Flow Indexer PlastometerTechnical parameters:Test methodMFR (unit: g / 10min)Temperature rangeroom temperature ~ 300 ℃Temperature accuracy± 0.5 ℃Temperature Resolution0.1 ℃Measuring range0.1 ~ 300g / 10min (MFR)load3.187 ~ 211.82N is divided into eightBarrel diameterф9.55mm ± 0.025mmDie apertureΦ2.095 ± 0.005mmPowerAC220V±10% 50Hz 1kWDimension300mm×400mm×500mmWeight35kg ABOUT USSKZ Industrial Co., Limited and SKZ International Co., Limited are the individuals of SKZ, which are specialised in furnish rubber trying out machine.SKZ&n
Contact Now
SKZ145 Melt Index Tester Mfi TesterFor engineering plastics such as polycarbonate, nylon, and fluorine plastics, whose melt temperatures are higher, as well as fit for plastics tests of polyethylene, polystyrene, polypropylene, ABS resin, and poly-formaldehyde resin, etc., whose melt temperatures are lower, the following parameters must be determined: melt mass-flow (MFR) (g/10min), melt volume-flow rate (cm3/10min), and the melt density of thermo resin.Standards:ISO 1133-1, ISO 1133-2, GBT 3682.1-2018, ASTM D1238-2013, ASTM D3364-1999 (2011), JJG878-1994, JB/T5456-2016, DIN53735, UNI-5640Char
Contact Now
SKZ145A Melt Flow Indexer MFR instrumentTechnical parameters:Test methodMFR (unit: g / 10min)Temperature rangeroom temperature ~ 300 ℃Temperature accuracy± 0.5 ℃Temperature Resolution0.1 ℃Measuring range0.1 ~ 300g / 10min (MFR)load3.187 ~ 211.82N is divided into eightBarrel diameterф9.55mm ± 0.025mmDie apertureΦ2.095 ± 0.005mmPowerAC220V±10% 50Hz 1kWDimension300mm×400mm×500mmWeight35kg ABOUT USSKZ Industrial Co., Limited and SKZ International Co., Limited are the humans of SKZ, which are specialised in furnish rubber attempting out machine.SKZ installed 
Contact Now
Standard: ISO1133 Feature:1. LCD display, time, temperature and sample times can be set.2. Built-in printer 3. Automatic cutting4. MFR test item Technical parameters:Test methodMFR (unit: g / 10min)Temperature rangeroom temperature ~ 300 ℃Temperature accuracy± 0.5 ℃Temperature Resolution0.1 ℃Measuring range0.1 ~ 300g / 10min (MFR)load3.187 ~ 211.82N is divided into eightBarrel diameterф9.55mm ± 0.025mmDie apertureΦ2.095 ± 0.005mmPowerAC220V±10% 50Hz 1kWDimension300mm×400mm×500mmWeight 35kg
Contact Now
SKZ145 ISO1133 Manufacture Auto LCD Melt Flow Indexer Factory Melt Flow IndexerStandards:ISO 1133-1:2011 Plastics — Determination of the soften mass-flow price (MFR) and soften volume-flow price (MVR) of thermoplastics —Part 1:Standard methodISO 1133-2:2011 Plastics — Determination of the soften mass-flow charge (MFR) and soften volume-flow charge (MVR) of thermoplastics —Part 2: Method for substances touchy to time temperature records and/or moistureASTM D1238-2013 "Standard Test Meth
Contact Now
NTV-AI High temperature ViscometerThe viscometer is used to measure the absolute viscosity of Newtonian fluid and non-Newtonian fluids the apparent viscosity, a measure of sensitivity, the test results are reliable, easy to operate, nice shape, can be widely used for Hot melt adhesive, asphalt, paraffin waxFeatures:1. The 7-inch large intelligent touch operation, the operation is simple and convenient, and it can display the dynamic viscosity value, the kinematic viscosity value, and the viscosity-temperature curve.2.
Contact Now
Product Introduction★ Flexible and flexible pumping system.The gas sampling pump's flow rate can be adjusted in ten increments to personalize the detection flow for varied settings.★ Multi-layered filter.The three-layer filter unit efficiently filters oil, water, dust, and other pollutants.
Contact Now
SKZ1050 Gas Monitor 0-30%VOL O2 Level Detector Gas Tester With Industrial Oxygen SensorFunction1.A single key that may be withdrawn from abuse issues to return the system to its original state.2.Two alarm points with light and sound, each with customisable settings.3.A large-capacity rechargeable lithium polymer battery.4.Adjustable suction pump with pump suction sampling.Specifications Gas Detected O2Detection principle Electrochemical principlesSampling Method Pump- suction, flow up 1L/min, pump suction size ten stalls adjustable Data logger100,000 set
Contact Now
Product descriptionThe SKZ1050E portable multi-gas detector is an upgraded version of the SKZ1050 that offers advanced features and functionalities for gas detection and monitoring. SpecificationsGas DetectedAs request (customize)Detection principleInfrared principles/ Electrochemistry principles/Catalytic combustion principles/Thermal Conduction Principle/Photoionization principlesSampling methodBuilt-in stable flow pump, each flow pump is equipped in each independent module, pump flow is adjustable in ten steps, flow range: 0-500 mL/MinModular structure
Contact Now
DSC Differential Scanning Calorimeter SKZ1052Product descriptionDSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control.
Contact Now
SKZ1052C-1L Differential Scanning Calorimeter360° lab and factory: https://skztester.en.alibaba.com/company_profile.html?spm=a2700.shop_oth.8.9DSC Video: https://youtu.be/m9z9fUnwLvg DSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control.
Contact Now
SKZ-1052 DSC Test Differential Scanning Calorimeter For LabDSC is designed to decide the internal warmth transition touching on to temperature and heat flow, it is extensively used in the area of polymer development, overall performance trying out & first-rate control.
Contact Now
SKZ1052 differential scanning calorimetry dsc analysisPerformance testing, quality control, and polymer research all make extensive use of DSC.The goal is to determine how temperature and heat flow relate to the inner heat transition.DSC research and development encompasses the domains of glass transition temperature,melting point, phase transition, cold crystallization, and ox
Contact Now
DSC is widely utilized in the fields of polymer research, performance testing, and quality control. It is intended to identify the inner heat transition in relation to temperature and heat flow. The fields of glass transition temperature, melting point, cold crystallization, phase transition, and oxidation induction time (OIT) are all included in DSC study and development.Standards:ISO/TR10837:1991, ASTM D3895-1998, ASTM E 967, ASTM E 968, ASTM E 793, ASTM D 3895, ASTM D 3417, ASTM D 3418, ISO 11357-6Features: 1. Rich information is shown on an industrial-grade 7-inch touch screen.2.
Contact Now
Product descriptionIt adopts 2.31-inch high-definition color screen for real-time display, and adopts gas sensors of well-known brands in the industry. Technical ParametersDetection gasCarbon monoxide COScope of detection0-500/ 1000/ 2000/ 5000ppm ,0-5000/10000ppm,10/ 20/ 50/ 100%VolResolution0.1 PPM/ 1 PPM/ 0.01%VOLDetection principleInfrared principles/ Electrochemistry principlesSensor life2-3 years/ 5 yearsDetection methodBuilt-in pump suction, flow rate 500ml/minDisplay method2.31 inch 320X240 high-definition color screen display, 5-buttons operationDetection ac
Contact Now
SKZ144 Rubber Vicat Softening Point Tester used to calculate the Vicat softening and heat distortion temperatures of polymer materialsCharacteristic1.Using a temperature controller to set the temperature and a meter to measure distortion.2.
Contact Now
IGT Printability Tester SKZ1032Printability Tester is a most basic designed for paper and paperboard printing picking printability test development of computer process control apparatus. Applicable to all kinds of offset, letterpress and gravure paper and cardboard printing simulation test. Equipped with a high speed ink refilling equipment, a standard scale, aluminum printing plates, wrapping paper.StandardsISO3782, GB/T2679.15, QB/T1058,TAPPI 514 and 575, SCAN P 63:90 Feature: ① the control system accurate.
Contact Now
New Schopper-riegler Beating Pulp Tester SKZ115The instrument is applicable in testing all kinds of suspending pulp liquid that less than 100°SR--- Schopper-Riegler.Standards:QB/T1054-98, GB/T3332-1982 and ISO5267/1.Feature: 1. hydraulic pressure structure with stainless steel 2. confirms to Standard ISO 3332-1982 and ISO5267/13. filters’s material is phosphor bronze, with its working area 100cm2 Technical parameters:Range0-100°SRMinimum scale1°SRTemperature of distilled water20±0.5 ℃Volume of distilled water1000 mlDraining time149±1 sDimension460×250 (mm)Weight 35kg
Contact Now
Schopper-Riegler Beating Freeness Tester MachineStandards:QB/T1054-98, GB/T3332-1982 and ISO5267/1.Feature:1. hydraulic pressure structure with stainless steel2. confirms to Standard ISO 3332-1982 and ISO5267/13.
Contact Now
Five-point heat-seal Tester (also known as gradient heat seal tester) can be used to determine the heat sealing temperature range , suitable packaging speed, and heat sealing pressure of the plastic film substrate, the flexible packaging composite film, coated paper and other heat sealing composite membrane. It can also work with tensile tester to do heat seal strength test. Structure: Divided into four parts of the air drive system, heat sealing device, temperature control system, time-conditioning systems. 1).
Contact Now
Hot Selling Ultraviolet Protection Tester For testing textiles UV transmittance and UV protection performance, can be directly measured ultraviolet protection factor UVA, UVB, UPF.Standards AATCC 183, AS/NZS 4399, BS 7914 PREN13758.Feature 1. HERAEUS deuterium lamp2. Ultraviolet photoelectric sensor, can measure the fluorescent sample.3.
Contact Now