LCD Melt Flow Indexer MRF MVR Meter ISO1133 400degree MFI EquipmentStandards:ISO 1133-1:2011 Plastics — Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics —Part 1:Standard methodISO 1133-2:2011 Plastics — Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics —Part 2: Method for materials sensitive to time temperature history and/or moistureGBT 3682.1-2018 "Plastic Thermoplastic Melt Mass Flow Rate (MFR) and Melt Volume Flow Rate (MVR) Determination"ASTM D1238-2013 "Standard Test Method
Contact Now
SKZ145 Melt Flow Rate TesterMelt mass-flow (MFR) (g/10min), melt volume-flow rate (cm3/10min), and the melt density of thermo resin must be determined for engineering plastics, which have higher melt temperatures, such as polycarbonate, nylon, and fluorine plastics; and for fit for plastics tests, which have lower melt temperatures, such as polyethylene, polystyrene, polypropylene, ABS resin, and poly-formaldehyde resin, etc.Standards:ISO 1133-1, ISO 1133-2, GBT 3682.1-2018, ASTM D1238-2013, ASTM D3364-1999 (2011), JJG878-1994, JB/T5456-2016, DIN53735, UNI-5640Product features:1.The control sy
Contact Now
To determine the melt mass-flow MFR (g/10min), the melt volume-flow rate MFV(cm3/10min) and the melt density of thermo resin, for the engineering plastics of polycarbonate, nylon and fluorine plastics, whose melt temperature are higher, but also fit for the plastics tests of polyethylene, polystyrene, polypropylene, ABS resin and poly-formaldehyde resin, etc, whose melt temperature are lower, widely applied to the fields of plastics materials, product, petrochemical.Standards:ISO 1133-1:2011 Plastics — Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplas
Contact Now
SKZ145A Melt Flow Indexer PlastometerTechnical parameters:Test methodMFR (unit: g / 10min)Temperature rangeroom temperature ~ 300 ℃Temperature accuracy± 0.5 ℃Temperature Resolution0.1 ℃Measuring range0.1 ~ 300g / 10min (MFR)load3.187 ~ 211.82N is divided into eightBarrel diameterф9.55mm ± 0.025mmDie apertureΦ2.095 ± 0.005mmPowerAC220V±10% 50Hz 1kWDimension300mm×400mm×500mmWeight35kg ABOUT USSKZ Industrial Co., Limited and SKZ International Co., Limited are the individuals of SKZ, which are specialised in furnish rubber trying out machine.SKZ&n
Contact Now
SKZ145 Melt Index Tester Mfi TesterFor engineering plastics such as polycarbonate, nylon, and fluorine plastics, whose melt temperatures are higher, as well as fit for plastics tests of polyethylene, polystyrene, polypropylene, ABS resin, and poly-formaldehyde resin, etc., whose melt temperatures are lower, the following parameters must be determined: melt mass-flow (MFR) (g/10min), melt volume-flow rate (cm3/10min), and the melt density of thermo resin.Standards:ISO 1133-1, ISO 1133-2, GBT 3682.1-2018, ASTM D1238-2013, ASTM D3364-1999 (2011), JJG878-1994, JB/T5456-2016, DIN53735, UNI-5640Char
Contact Now
SKZ145A Melt Flow Indexer MFR instrumentTechnical parameters:Test methodMFR (unit: g / 10min)Temperature rangeroom temperature ~ 300 ℃Temperature accuracy± 0.5 ℃Temperature Resolution0.1 ℃Measuring range0.1 ~ 300g / 10min (MFR)load3.187 ~ 211.82N is divided into eightBarrel diameterф9.55mm ± 0.025mmDie apertureΦ2.095 ± 0.005mmPowerAC220V±10% 50Hz 1kWDimension300mm×400mm×500mmWeight35kg ABOUT USSKZ Industrial Co., Limited and SKZ International Co., Limited are the humans of SKZ, which are specialised in furnish rubber attempting out machine.SKZ installed 
Contact Now
Standard: ISO1133 Feature:1. LCD display, time, temperature and sample times can be set.2. Built-in printer 3. Automatic cutting4. MFR test item Technical parameters:Test methodMFR (unit: g / 10min)Temperature rangeroom temperature ~ 300 ℃Temperature accuracy± 0.5 ℃Temperature Resolution0.1 ℃Measuring range0.1 ~ 300g / 10min (MFR)load3.187 ~ 211.82N is divided into eightBarrel diameterф9.55mm ± 0.025mmDie apertureΦ2.095 ± 0.005mmPowerAC220V±10% 50Hz 1kWDimension300mm×400mm×500mmWeight 35kg
Contact Now
SKZ145 ISO1133 Manufacture Auto LCD Melt Flow Indexer Factory Melt Flow IndexerStandards:ISO 1133-1:2011 Plastics — Determination of the soften mass-flow price (MFR) and soften volume-flow price (MVR) of thermoplastics —Part 1:Standard methodISO 1133-2:2011 Plastics — Determination of the soften mass-flow charge (MFR) and soften volume-flow charge (MVR) of thermoplastics —Part 2: Method for substances touchy to time temperature records and/or moistureASTM D1238-2013 "Standard Test Meth
Contact Now
NTV-AI High temperature ViscometerThe viscometer is used to measure the absolute viscosity of Newtonian fluid and non-Newtonian fluids the apparent viscosity, a measure of sensitivity, the test results are reliable, easy to operate, nice shape, can be widely used for Hot melt adhesive, asphalt, paraffin waxFeatures:1. The 7-inch large intelligent touch operation, the operation is simple and convenient, and it can display the dynamic viscosity value, the kinematic viscosity value, and the viscosity-temperature curve.2.
Contact Now
Product Introduction★ Flexible and flexible pumping system.The gas sampling pump's flow rate can be adjusted in ten increments to personalize the detection flow for varied settings.★ Multi-layered filter.The three-layer filter unit efficiently filters oil, water, dust, and other pollutants.
Contact Now
DSC Differential Scanning Calorimeter SKZ1052Product descriptionDSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control.
Contact Now
Product descriptionThe SKZ1050E portable multi-gas detector is an upgraded version of the SKZ1050 that offers advanced features and functionalities for gas detection and monitoring. SpecificationsGas DetectedAs request (customize)Detection principleInfrared principles/ Electrochemistry principles/Catalytic combustion principles/Thermal Conduction Principle/Photoionization principlesSampling methodBuilt-in stable flow pump, each flow pump is equipped in each independent module, pump flow is adjustable in ten steps, flow range: 0-500 mL/MinModular structure
Contact Now
SKZ1050 Gas Monitor 0-30%VOL O2 Level Detector Gas Tester With Industrial Oxygen SensorFunction1.A single key that may be withdrawn from abuse issues to return the system to its original state.2.Two alarm points with light and sound, each with customisable settings.3.A large-capacity rechargeable lithium polymer battery.4.Adjustable suction pump with pump suction sampling.Specifications Gas Detected O2Detection principle Electrochemical principlesSampling Method Pump- suction, flow up 1L/min, pump suction size ten stalls adjustable Data logger100,000 set
Contact Now
SKZ-1052 DSC Test Differential Scanning Calorimeter For LabDSC is designed to decide the internal warmth transition touching on to temperature and heat flow, it is extensively used in the area of polymer development, overall performance trying out & first-rate control.
Contact Now
SKZ1052C-1L Differential Scanning Calorimeter360° lab and factory: https://skztester.en.alibaba.com/company_profile.html?spm=a2700.shop_oth.8.9DSC Video: https://youtu.be/m9z9fUnwLvg DSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control.
Contact Now
SKZ1052 differential scanning calorimetry dsc analysisPerformance testing, quality control, and polymer research all make extensive use of DSC.The goal is to determine how temperature and heat flow relate to the inner heat transition.DSC research and development encompasses the domains of glass transition temperature,melting point, phase transition, cold crystallization, and ox
Contact Now
DSC is widely utilized in the fields of polymer research, performance testing, and quality control. It is intended to identify the inner heat transition in relation to temperature and heat flow. The fields of glass transition temperature, melting point, cold crystallization, phase transition, and oxidation induction time (OIT) are all included in DSC study and development.Standards:ISO/TR10837:1991, ASTM D3895-1998, ASTM E 967, ASTM E 968, ASTM E 793, ASTM D 3895, ASTM D 3417, ASTM D 3418, ISO 11357-6Features: 1. Rich information is shown on an industrial-grade 7-inch touch screen.2.
Contact Now
Product descriptionIt adopts 2.31-inch high-definition color screen for real-time display, and adopts gas sensors of well-known brands in the industry. Technical ParametersDetection gasCarbon monoxide COScope of detection0-500/ 1000/ 2000/ 5000ppm ,0-5000/10000ppm,10/ 20/ 50/ 100%VolResolution0.1 PPM/ 1 PPM/ 0.01%VOLDetection principleInfrared principles/ Electrochemistry principlesSensor life2-3 years/ 5 yearsDetection methodBuilt-in pump suction, flow rate 500ml/minDisplay method2.31 inch 320X240 high-definition color screen display, 5-buttons operationDetection ac
Contact Now
SKZ1050B Fixed HCHO Monitor Gas Detection Equipment 0-100PPM Formaldehyde CH2O Fixed Gas DetectorFunction 1.Environmental monitoring or GAS pipeline concentration and alarm2.Temperature compensation can be used to create the ideal conditions for varying gas concentration temperatures. 3.It is possible to remotely control infrared devices without having to open the alarm set point, zero calibration, change the address, or do other tasks. SpecificationsGas DetectedCH2ODetection principleElectrochemical principlesSampling MethodWall-mounted, pipeline, flow typeMeasure Range0-1
Contact Now
SKZ1050-N2 Nitrogen Gas Alarm DetectorSKZ1050 series gas detector is a kind of fast response and high accuracy gas measurement device. With internal sampling pump, fast sampling speed and high flow rate ensuring the response time of the detecfor. Unique design,small size and easy to carry with.Special high intensity engineering plastics housing,suitable for different kinds of situation and environment. We dedicate to provide you the most reliable accurate and the safest solution of gas detection.Function1.
Contact Now
SKZ129B DIN Abrasion Tester DIN AbraderStandard ISO4649, DIN 53516Technical parameters:Sample load2.5N, 5N,10NStroke40m or 20mRoller speed40 ± 1r/minRoller diameterФ150 ± 0.2mmRoller length460mmSample dia.Ф16 ± 0.2mmPowerAC220V ± 10% 50HzDimension700mm × 340mm × 300mmWeight63kgEXCELLENT PERFORMANCE,SUPERB TECHNOLOGYStainless steel rollerAnti-corrosion and anti-rustThe operation interface is simple and clearStandard: lS04649, DIN 53516PRODUCT DISPLAYSKZ129B is suitable for wear testing ofelastic materials, rubbertires, conveyor belts, soles, soft synthetic leather, leather andother materials, w
Contact Now
SKZ144 Rubber Vicat Softening Point Tester used to calculate the Vicat softening and heat distortion temperatures of polymer materialsCharacteristic1.Using a temperature controller to set the temperature and a meter to measure distortion.2.
Contact Now
Digital Melting Point Tester SKZ1040BDetermination of the melting point of crystalline substance to determine purity of drugs, dyes, perfumes and the like crystals of organic compounds Feature1. Photoelectric detection2. large backlit LCD screen display3. Numeric keypad. Melting curve can be displayed directly4.
Contact Now
Automatic Carton Stiffness Tester SKZ105BThe tester is used to evaluate the stiffness and resiliency of cardboard by international Taber method.Feature1. 5.7in LCD, real-time display stiffness value and curves2. Automatic zero adjustment.3. Display memory, statistics and print of test results4. The angle can be set between (1 ~ 90) °.5. Test time is within a predetermined range (3s ~ 35s) arbitrarily set.6.
Contact Now