LCD Melt Flow Indexer MRF MVR Meter ISO1133 400degree MFI EquipmentStandards:ISO 1133-1:2011 Plastics — Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics —Part 1:Standard methodISO 1133-2:2011 Plastics — Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics —Part 2: Method for materials sensitive to time temperature history and/or moistureGBT 3682.1-2018 "Plastic Thermoplastic Melt Mass Flow Rate (MFR) and Melt Volume Flow Rate (MVR) Determination"ASTM D1238-2013 "Standard Test Method
Contact Now
SKZ145A Melt Flow Indexer PlastometerTechnical parameters:Test methodMFR (unit: g / 10min)Temperature rangeroom temperature ~ 300 ℃Temperature accuracy± 0.5 ℃Temperature Resolution0.1 ℃Measuring range0.1 ~ 300g / 10min (MFR)load3.187 ~ 211.82N is divided into eightBarrel diameterф9.55mm ± 0.025mmDie apertureΦ2.095 ± 0.005mmPowerAC220V±10% 50Hz 1kWDimension300mm×400mm×500mmWeight35kg ABOUT USSKZ Industrial Co., Limited and SKZ International Co., Limited are the individuals of SKZ, which are specialised in furnish rubber trying out machine.SKZ&n
Contact Now
SKZ145A Melt Flow Indexer MFR instrumentTechnical parameters:Test methodMFR (unit: g / 10min)Temperature rangeroom temperature ~ 300 ℃Temperature accuracy± 0.5 ℃Temperature Resolution0.1 ℃Measuring range0.1 ~ 300g / 10min (MFR)load3.187 ~ 211.82N is divided into eightBarrel diameterф9.55mm ± 0.025mmDie apertureΦ2.095 ± 0.005mmPowerAC220V±10% 50Hz 1kWDimension300mm×400mm×500mmWeight35kg ABOUT USSKZ Industrial Co., Limited and SKZ International Co., Limited are the humans of SKZ, which are specialised in furnish rubber attempting out machine.SKZ installed 
Contact Now
To determine the melt mass-flow MFR (g/10min), the melt volume-flow rate MFV(cm3/10min) and the melt density of thermo resin, for the engineering plastics of polycarbonate, nylon and fluorine plastics, whose melt temperature are higher, but also fit for the plastics tests of polyethylene, polystyrene, polypropylene, ABS resin and poly-formaldehyde resin, etc, whose melt temperature are lower, widely applied to the fields of plastics materials, product, petrochemical.Standards:ISO 1133-1:2011 Plastics — Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplas
Contact Now
SKZ145 Melt Flow Rate TesterMelt mass-flow (MFR) (g/10min), melt volume-flow rate (cm3/10min), and the melt density of thermo resin must be determined for engineering plastics, which have higher melt temperatures, such as polycarbonate, nylon, and fluorine plastics; and for fit for plastics tests, which have lower melt temperatures, such as polyethylene, polystyrene, polypropylene, ABS resin, and poly-formaldehyde resin, etc.Standards:ISO 1133-1, ISO 1133-2, GBT 3682.1-2018, ASTM D1238-2013, ASTM D3364-1999 (2011), JJG878-1994, JB/T5456-2016, DIN53735, UNI-5640Product features:1.The control sy
Contact Now
Standard: ISO1133 Feature:1. LCD display, time, temperature and sample times can be set.2. Built-in printer 3. Automatic cutting4. MFR test item Technical parameters:Test methodMFR (unit: g / 10min)Temperature rangeroom temperature ~ 300 ℃Temperature accuracy± 0.5 ℃Temperature Resolution0.1 ℃Measuring range0.1 ~ 300g / 10min (MFR)load3.187 ~ 211.82N is divided into eightBarrel diameterф9.55mm ± 0.025mmDie apertureΦ2.095 ± 0.005mmPowerAC220V±10% 50Hz 1kWDimension300mm×400mm×500mmWeight 35kg
Contact Now
SKZ145 Melt Index Tester Mfi TesterFor engineering plastics such as polycarbonate, nylon, and fluorine plastics, whose melt temperatures are higher, as well as fit for plastics tests of polyethylene, polystyrene, polypropylene, ABS resin, and poly-formaldehyde resin, etc., whose melt temperatures are lower, the following parameters must be determined: melt mass-flow (MFR) (g/10min), melt volume-flow rate (cm3/10min), and the melt density of thermo resin.Standards:ISO 1133-1, ISO 1133-2, GBT 3682.1-2018, ASTM D1238-2013, ASTM D3364-1999 (2011), JJG878-1994, JB/T5456-2016, DIN53735, UNI-5640Char
Contact Now
SKZ145 ISO1133 Manufacture Auto LCD Melt Flow Indexer Factory Melt Flow IndexerStandards:ISO 1133-1:2011 Plastics — Determination of the soften mass-flow price (MFR) and soften volume-flow price (MVR) of thermoplastics —Part 1:Standard methodISO 1133-2:2011 Plastics — Determination of the soften mass-flow charge (MFR) and soften volume-flow charge (MVR) of thermoplastics —Part 2: Method for substances touchy to time temperature records and/or moistureASTM D1238-2013 "Standard Test Meth
Contact Now
NTV-AI High temperature ViscometerThe viscometer is used to measure the absolute viscosity of Newtonian fluid and non-Newtonian fluids the apparent viscosity, a measure of sensitivity, the test results are reliable, easy to operate, nice shape, can be widely used for Hot melt adhesive, asphalt, paraffin waxFeatures:1. The 7-inch large intelligent touch operation, the operation is simple and convenient, and it can display the dynamic viscosity value, the kinematic viscosity value, and the viscosity-temperature curve.2.
Contact Now
Product Introduction★ Flexible and flexible pumping system.The gas sampling pump's flow rate can be adjusted in ten increments to personalize the detection flow for varied settings.★ Multi-layered filter.The three-layer filter unit efficiently filters oil, water, dust, and other pollutants.
Contact Now
Product descriptionThe SKZ1050E portable multi-gas detector is an upgraded version of the SKZ1050 that offers advanced features and functionalities for gas detection and monitoring. SpecificationsGas DetectedAs request (customize)Detection principleInfrared principles/ Electrochemistry principles/Catalytic combustion principles/Thermal Conduction Principle/Photoionization principlesSampling methodBuilt-in stable flow pump, each flow pump is equipped in each independent module, pump flow is adjustable in ten steps, flow range: 0-500 mL/MinModular structure
Contact Now
DSC Differential Scanning Calorimeter SKZ1052Product descriptionDSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control.
Contact Now
SKZ-1052 DSC Test Differential Scanning Calorimeter For LabDSC is designed to decide the internal warmth transition touching on to temperature and heat flow, it is extensively used in the area of polymer development, overall performance trying out & first-rate control.
Contact Now
SKZ1052C-1L Differential Scanning Calorimeter360° lab and factory: https://skztester.en.alibaba.com/company_profile.html?spm=a2700.shop_oth.8.9DSC Video: https://youtu.be/m9z9fUnwLvg DSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control.
Contact Now
SKZ1052 differential scanning calorimetry dsc analysisPerformance testing, quality control, and polymer research all make extensive use of DSC.The goal is to determine how temperature and heat flow relate to the inner heat transition.DSC research and development encompasses the domains of glass transition temperature,melting point, phase transition, cold crystallization, and ox
Contact Now
Product descriptionIt adopts 2.31-inch high-definition color screen for real-time display, and adopts gas sensors of well-known brands in the industry. Technical ParametersDetection gasCarbon monoxide COScope of detection0-500/ 1000/ 2000/ 5000ppm ,0-5000/10000ppm,10/ 20/ 50/ 100%VolResolution0.1 PPM/ 1 PPM/ 0.01%VOLDetection principleInfrared principles/ Electrochemistry principlesSensor life2-3 years/ 5 yearsDetection methodBuilt-in pump suction, flow rate 500ml/minDisplay method2.31 inch 320X240 high-definition color screen display, 5-buttons operationDetection ac
Contact Now
DSC is widely utilized in the fields of polymer research, performance testing, and quality control. It is intended to identify the inner heat transition in relation to temperature and heat flow. The fields of glass transition temperature, melting point, cold crystallization, phase transition, and oxidation induction time (OIT) are all included in DSC study and development.Standards:ISO/TR10837:1991, ASTM D3895-1998, ASTM E 967, ASTM E 968, ASTM E 793, ASTM D 3895, ASTM D 3417, ASTM D 3418, ISO 11357-6Features: 1. Rich information is shown on an industrial-grade 7-inch touch screen.2.
Contact Now
SKZ1040A-2 Microscopic Melting Point MeterMicroscopic Melting Point Meter, which uses a single-purpose microscope to observe the melting state of the sample to be tested, has an ultra-high cost performance, simple and stylish appearance, and simple and convenient operation; both the capillary method and the hot stage method can be used to measure the melting point of the sample, and the application field is more Extensive; it is the industry's first to adopt digital temperature control and closed-loop control to control the furnace temperature, which makes the furnace temperature control m
Contact Now
SKZ60G precision gloss meter projection Angle is 60 degrees, precision gloss meter measurement mode has automatic measurement, manual measurement, single measurement, average measurement, and can achieve cross-setting, providing a variety of combination of measurement modes.Functional characteristics1.Delicate, lightweight shape, carry, use are very convenient 2.Automatic calibration, no manual adjustment, high stability, that is, open measurement 3.Full intelligent design, single key operation, single hand can achieve all operations, easy to use 4.Long life light source, no nee
Contact Now
Product DescriptionDigital Multi Parameter Meter Ph Ec Tds Meter M510T Features:1. Color High contrast LCD touchscreen, 4.3 inches.2. Intelligent operation system provides features including user management, calibration management, electrode management, method management, data management, Log Management and etc.3. Multi-reading feature allows auto-read, timed-read and continuous-read.4. Automatic/Manual temperature compensation ensures accurate results.5. Auto-hold feature senses and locks the measurement endpoint.6. Data Storage 1000 sets for each parameter (GLP-compliant).7.
Contact Now
Used to test the Vicat softening temperature and heat distortion temperature of polymer materials Feature 1.Using meter to measure distortion and temperature controller to set temperature.2. Specimen stand can automatically go up and down and test 3 specimens in one time.
Contact Now
Portable Gloss Meter SKZ117 Function: (1) One button to entire triangle measurement: one operation can entire three perspective measurement; Measuring mild incident attitude meet ISO 2813 three measuring mild incident angle.
Contact Now
Electrical Conductivity Meter EC310T General Feature1. Colour high contrast LCD touch screen, 4.3 inches2. Multi-reading function allows automatic, timed and continuous readings3. Automatic/manual temperature compensation ensures accurate results 4. Auto hold function senses and locks the endpoint of the measurement.5. 500 data sets per parameter (GLP compliant)6. Supports USB communication7. Auto Power Off function extends battery life.8. Reset function automatically restores all settings to factory defaults9.
Contact Now
EC310F Laboratory Cond Meter Water EC Conductivity Meter GENERAL FEATURES1. LCD display screen, 3.5 inches.2. Multi-reading feature allows auto-read, timed-read and continuous-read.3. Automatic/Manual temperature compensation ensures accurate results.4. Auto-hold feature senses and locks the measurement endpoint.5. Data capacity of up to 500 sets for each parameter (GLP-compliant).6. Support for USB communication.7. Auto-power off feature effectively extends the battery service life.8. Reset feature automatically resumes all settings back to factory default options.9. IP65 waterproof.
Contact Now