Low Temperature Differential Scanning Calorimeter-manufacture,factory,supplier from China

(Total 24 Products for Low Temperature Differential Scanning Calorimeter)
SKZ1052 Differential Scanning CalorimeterDSC is intended to decide the internal intensity progress connecting with temperature and intensity stream, it is broadly utilized in the field of polymer improvement, execution testing and quality control.
  Contact Now
SKZ1052C-1L Differential Scanning Calorimeter360° lab and factory: https://skztester.en.alibaba.com/company_profile.html?spm=a2700.shop_oth.8.9DSC Video: https://youtu.be/m9z9fUnwLvg DSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control.
  Contact Now
SKZ1052 Differential Scanning Calorimeter (DSC)Performance testing, pleasant control, and polymer lookup all make full-size use of DSC.The purpose is to decide how temperature and warmth glide relate to the internal warmth transition.DSC lookup and improvement encompasses the domains of glass transition temperature,melting point, segment transition, bloodless crystallization, and oxidation induction time (OIT).Features:1.
  Contact Now
DSC Differential Scanning Calorimeter SKZ1052Product descriptionDSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control.
  Contact Now
SKZ-1052 DSC Test Differential Scanning Calorimeter For LabDSC is designed to decide the internal warmth transition touching on to temperature and heat flow, it is extensively used in the area of polymer development, overall performance trying out & first-rate control.
  Contact Now
SKZ1052 Automatic Pressure Differential Scanning Calorimeter Deutsch For SaleMain Features:1. The industrial-grade 7-inch contact display screen shows prosperous information.2. Brand-new steel furnace physique structure, with higher baseline and greater accuracy. The heating adopts oblique conduction method, which has excessive uniformity andstability, reduces pulse radiation, and is higher than standard heating mode.3.
  Contact Now
SKZ1052 Dsc Differential scanning calorimetry InstrumentsMain Features:1. The industrial-grade 7-inch contact show display screen suggests affluent information.2. Brand-new metal furnace physique structure, with greater baseline and increased accuracy. The heating adopts indirect conduction method, which has immoderate uniformity andstability, reduces pulse radiation, and is greater than general heating mode.3. USB dialog interface, sturdy versatility, reliable and uninterrupted communication, helps self-recovery connection function.4.
  Contact Now
SKZ1052 differential scanning calorimetry dsc analysisPerformance testing, quality control, and polymer research all make extensive use of DSC.The goal is to determine how temperature and heat flow relate to the inner heat transition.DSC research and development encompasses the domains of glass transition temperature,melting point, phase transition, cold crystallization, and ox
  Contact Now
High and low temperature test chamber is one of the climate simulation chambers for the assessment of various electronic products, test at high temperature, low temperature environment.Features:1.Unique balance thermostat, high precision, high temperature stability control.2.Temperature controller with high precision, high stability, PID self-tuning, LED visual display, to ensure precise control of equipment. Equipment with over-temperature3.
  Contact Now
DSC is widely utilized in the fields of polymer research, performance testing, and quality control. It is intended to identify the inner heat transition in relation to temperature and heat flow. The fields of glass transition temperature, melting point, cold crystallization, phase transition, and oxidation induction time (OIT) are all included in DSC study and development.Standards:ISO/TR10837:1991, ASTM D3895-1998, ASTM E 967, ASTM E 968, ASTM E 793, ASTM D 3895, ASTM D 3417, ASTM D 3418, ISO 11357-6Features: 1. Rich information is shown on an industrial-grade 7-inch touch screen.2.
  Contact Now
SKZ1055 Differential Thermal AnalyzerDifferential thermal analysis: temperature under program control, the relationship and difference of temperature between the measured material and the reference.The DTA curves is to describe the changing relationship depending on temperature and time between the measured material and the reference compound. During the test, the sample temperature changes due to the phase change or an endothermic or exothermic reaction effects.
  Contact Now
SKZ133 Rubber Brittleness TesterUsed to test the highest temperature called brittleness temperature when the specimen is broken by impact in prescribed conditions.
  Contact Now
SKZ XRY-1A  Automatic Oxygen Bomb Calorimeter For Coal AnalysisIt is suitable to determine calorific value of combustible materials such as petroleum products without water (gasoline, jet fuels, diesel oil and fuel oils, etc.), coal, coke and paraffin, etc.Main technical specifications1. Heat capacity: 14400 J/K~15000 J/K2. Resolution: 0.001 K3. Measurement accuracy: ± 60J/g4. Repeatability: ≤0.2% (Grade C)5. Pressure endurance of oxygen bomb: 20 MPa6. Temperature measurement range: 10 ℃~35 ℃7.
  Contact Now
Used to test the highest temperature called brittleness temperature when the specimen is broken by impact in prescribed conditions.
  Contact Now
SKZ1064 Oxygen Bomb CalorimeterOxygen bomb calorimeter can be used to measure the calorific value of solid or liquid samples, measuring samples in a closed container (oxygen bomb), oxygen-filled environment, the heat generated by combustion, the measurement results called the combustion value, calorific value , BTU and so on. Calorific value results have the value of determining other values to determine the quality of the sample as a basis for calculating the price (eg, coal), as well as physiology (eg, energy distribution in ecology, energy metabolism in animal nutrition studies, etc.),
  Contact Now
DTA Differential Thermal Analyzer SKZ1055Differential thermal analysis: temperature under program control, the relationship and difference of temperature between the measured material and the reference.The DTA curves is to describe the changing relationship depending on temperature and time between the measured material and the reference compound. During the test, the sample temperature changes due to the phase change or an endothermic or exothermic reaction effects.
  Contact Now
Digital Oxygen Bomb Calorimeter SKZ1064Oxygen bomb calorimeter can be used to measure the calorific value of solid or liquid samples, measuring samples in a closed container (oxygen bomb), oxygen-filled environment, the heat generated by combustion, the measurement results called the combustion value, calorific value , BTU and so on.Calorific value results have the value of determining other values to determine the quality of the sample as a basis for calculating the price (eg, coal), as well as physiology (eg, energy distribution in ecology, energy metabolism in animal nutrition studies, etc.
  Contact Now
SKZ XRY-1A+ Oxygen Bomb Calorimeter Description In ChemistryI. SummaryThe instrument is designed and made as per the National Standard of People’s Republic of China GB/T213-2008 and ASTM D240 Test Method for Calorific Value of coal, GB/T384-1988 Test Method for Calorific Value of Petroleum Products and Calibration Regulation of People’s Republic of China JJG672-2001 Oxygen Bomb CalorimeterII. Main technical specifications1. Power supply: AC 220V±5%, 50 Hz2. Total power consumption: ≤150W.3. Heat capacity: (14000~15000) J/K4. Resolution: 0.001 K5.
  Contact Now
-80℃~0℃ ISO812 ISO974—80 SKZ133 low temperature Rubber Brittleness EquipmentApplied for non-rigid plastic and other flexible materials at low temperatures and also test the brittleness temperature and low temperature performance for different rubber material or different formula vulcanized rubber. Standard: GB1682-82, ISO812:1991, ISO974—80.Technical parameters:Testing temperature-80℃~0℃Impact speed2 m/s±0.2 m/sImpactor weight200 ± 20gWorking stroke 40 ± 1mmTemperature fluctuation<±0.5℃Distance between impactor and clamp11±0.5 (mm)Distance between i
  Contact Now
NTV-AI High temperature ViscometerThe viscometer is used to measure the absolute viscosity of Newtonian fluid and non-Newtonian fluids the apparent viscosity, a measure of sensitivity, the test results are reliable, easy to operate, nice shape, can be widely used for Hot melt adhesive, asphalt, paraffin waxFeatures:1. The 7-inch large intelligent touch operation, the operation is simple and convenient, and it can display the dynamic viscosity value, the kinematic viscosity value, and the viscosity-temperature curve.2.
  Contact Now
SKZ144 Vicat Softening Temperature Tester Used to measure polymer materials' Vicat softening and heat distortion temperatures. Feature 1.Setting the temperature with a temperature controller and measuring distortion with a meter.2.The specimen stand has an automated up/down motion and can test three specimens simultaneously.Standard:ASTM-D1525, ASTM-D648, DIN53460,DIN53461,ISO-306,ISO-75Technical parameters: Temperature rangeroom temperature~350℃Heating speed(12±1)oC/6min[(120±10)oC/h](5±0.5)oC/6min[(50±5)oC/h]Max temperature error±0.1℃Measuring range of distortion0-1mmMeasu
  Contact Now
XRY-1A+ Oxygen Bomb Calorimeter Price For Sale It is appropriate to decide calorific price of flamable substances such as petroleum merchandise except water (gasoline, jet fuels, diesel oil and gas oils, etc.), coal, coke and paraffin, etc.Main technical features1. This instrument adopts sealed oxygen bomb. The total shape adopts stainless metal material. The power is adequate to face up to the max stress (60~70 atmospheric pressure) when the stable burning. And it can withstand the better stress when liquid gas burning.2.
  Contact Now
Used to test the Vicat softening temperature and heat distortion temperature of polymer materials  Feature 1.Using meter to measure distortion and temperature controller to set temperature.2. Specimen stand can automatically go up and down and test 3 specimens in one time.
  Contact Now
SKZ139 Rubber compression Deformation TesterContain by parallel steel plates, limiters and fasteners, used for vulcanized rubber, thermoplastic rubber in room temperature, high temperature and low temperature conditions, at a constant compression rate, after a certain compression time determination of the amount of deformation of rubber. Standard: ASTM-D395,ISO815.Technical parameters:Sample A: dia. 29mm, height: 12.5mmB: dia. 13mm, height: 6.3mmLimiters heightcompression rate 25%A: 9.3 ~ 9.4 B: 4.7 ~ 4.8Compression rate 15%A: 1
  Contact Now
Relate News
SKZ1052 high-precision differential scanning calorimeter is an instrument launched by SKZ for conducting material thermal analysis experiments. It can be used to test oxidation induction period, glass transition temperature, melting point, melting, enthalpy change, phase change, cold crystallization, crystallization, product stability, curing degree, cross-linking degree, specific heat capacity, reaction heat, etc. The instrument uses imported sensors with high sensitivity. Signal acquisition circuit shielding protection, strong anti-interference, and high baseline stability.
The SKZ2050-4 portable detection and alarm device is used for portable and rapid detection of toxic and harmful gas concentrations, temperature and humidity measurements, and for situations where excessive alarms are triggered.
Lab hot air oven is an indispensable utility for your daily workflow, from simple glassware drying to very complex temperature-controlled heating applications.
SKZ401 Rubber Vulcanizer is mainly used for vulcanizing flat type tape (such as conveyor belt, transmission belt, referred to as flat belt), belongs to hydraulic machinery, the main function of plate vulcanizing machine is to provide the pressure and temperature required for vulcanization. The pressure is generated by the hydraulic system through the hydraulic cylinder, and the temperature is provided by the heating medium (usually steam, thermal oil, etc., and superhot water is also useful).
This meter can test pH,mV, ORP, tesisitivity, TDS, salinity, dissolved oxygen and temperature in water solution, it is suitable used in lab for those units from industrial and mining enterprises,university and scientific research organ etc. There is a microprocessor chip inside the meter and the appearance of meter looks nice with easily operation.
Carbon black content tester is an instrument used to measure carbon black content in materials.The basic principle of the carbon black content tester is to quantitatively analyze the carbon black in the material by burning the carbon black in the sample in the oxygen environment.Method of applicationTo use the carbon black content tester, follow the following steps:Prepare the sample: Put 1g sample to be tested and put it into the combustion boat according to the test.Preheating: Turn on the tester, pass nitrogen for a few minutes, and set the temperature program.Place the sample: Place the pr
Dumplings are full, life is warm, dumplings are sweet and tender. Happy Dragon Boat Festival to my dearest relatives!
Minimeta is a maintenance-free single gas detector that is the most reliable, user-friendly and cost-effective inspection solution for ensuring worker safety and operational compliance. It provides protection for up to 2 years - no calibration, no sensor replacement, no battery replacement or battery charging.
SKZ108A/B Mullen Bursting Tester is a basic instrument for testing the strength of paper and paperboard.
Our SKZ111B-1 grain moisture meter is a portable and easy-to-use device that can accurately measure the moisture content of 33 different types of grains including coffee beans. It supports English language and comes with CE and ISO9001 certifications, ensuring the quality and safety of the product.This grain moisture meter is designed with convenience in mind. It is light in weight, compact, and easy to carry around, making it ideal for on-site measurements.