Infrared Online Moisture Analyzer SKZ111JSuitable for: food, metallurgy, tobacco, wood, paper processing, building materials, chemicals, mining, pharmaceutical, energy field.Features:Fast measurements:With long-life high-speed brushless motor, imported high response infrared sensors, information processing chip FPGA + DSP + ARM9 combination, to ensure the real-time data acquisition, improve measurement precision and stability.Reliability:With dual optical detectors, the optical system for monitoring and compensation, moisture measurement from the sensor to ensure effects of aging.Non-cont
Contact Now
SKZ111J Wood Chips Infrared Online Moisture Analyzer SensorInfrared Online Moisture Analyzer is a sophisticated device designed for non-contact, continuous, real-time, and on-line measurement of moisture content in various materials.
Contact Now
SKZ111J Infrared Online Moisture Sensor Analyzer On-line Measuring for TobaccoSuitable for: food, metallurgy, tobacco, wood, paper processing, building materials, chemicals, mining, pharmaceutical, energy field. Principle:It is the use of water molecules on the infrared spectral absorption characteristics, to measure the moisture content of the measured object.IR bands (0.78 ~ 2.5μm wavelength range of electromagnetic waves) absorption of water molecules is not the average, a strong wavelength at a low wavelength in the other.
Contact Now
SKZ111H Wood Chips Sawdust Wood Flour Wood Fibers Moisture AnalyzerUsing the high-frequency principle, high accuracyPTFE and 316L steel are used to make the wear-and corrosion-resistant sensor probe.At the eighth measurement, the switch stalls.Outstanding qualityA wide measurement range between 0 and 80%Compact, lightweight, and quick decision-making Technical parameters:DisplayLCD displyMeasuring range0 ~ 80%Resolution0.1%Accuracy0%-10%: ±0.2%10%-40%: ±0.5%40%-80%:±1%Probe600mmPower9V battery*1Dimesion160mm × 60mm × 27mmNet weight/gross weight250g/1kgPackage size610 X 110
Contact Now
SKZ1050E O2 Analyzer★ A 3.5-inch color screen with outstanding definition. The outside is composed of material resistant to wear in aircraft 2.
Contact Now
Laboratory Halogen Moisture Analyzer SKZ111L Quick (1-6 minutes) Determination of moisture of the measured object, using the principle of heating and drying, moisture values measured object is automatically displayed, the data is stable and accurate.Measurement: powder form, granular, paste, liquid, organic and inorganic chemical raw materials, a variety of cereals, grain, seed, feed, starch, food, meat, tobacco, tea, paper, grass, soil, sludge , textiles, fuel, resin, silica, plastic particles, coal, fertilizer, medicine, ceramics, wood, ore.F
Contact Now
Laser Particle Size Analyzer SKZ1062A Technical characteristic:Standard: ISO133201. The measurement ranges are 0.02~1200 μm (SKZ1062A-1) and 0.1~800 μm (SKZ1062A).2. Tolerance for accuracy: ± 1% (DS50 national standard)3. Repeatability deviation: ± 1% (based on national norm D50)4.
Contact Now
SKZ1062F Nano Particle Size Analyzer FeatureHigh-speed photon correlator and professional high-performance photomultiplier tube as the core device for fast, high resolution, repeatability and accuracy1. Advanced test principle: Using dynamic light scattering principle and photon correlation spectroscopy technology, the particle size is determined according to the speed of Brownian motion of the particles in the liquid. The small particle Brownian motion speed is fast, and the large particle Brownian motion speed is slow.
Contact Now
SKZ111C Dough Bread Moisture Tester Food Moisture Analyzer Humidity MeterSuitable for measuring moisture of dough, pasta, bread, cakes, moon cake stuffing, fishmeal, bean paste, date paste, fruit juices, dried fruit, dried vegetables, dried sweet potatoes, dried apples, dates, and the like sticky granules, blocks, granules, powder. Feature Using high-frequency principle, frequency more than 10MHZSensor probe is 316L steel + PTFE, it is corrosion, wear resistantWith 10th measurement switch stalls.
Contact Now
Wet Method Laser Particle Size Analyzer SKZ1062ATechnical parameter: Standard: ISO133201. Measuring range: 0.1~800 μm (SKZ1062A), 0.02~1200 μm (SKZ1062A-1)2. Accuracy tolerance: ± 1% (national standard D50) 3. Deviation of repeatability: ± 1% (national standard D50) 4.
Contact Now
SKZ111J Paddy Peanut Moisture Testing Machine Meter Price Online ShoppingSuitable for: food, grain,metallurgy, tobacco, wood, paper processing, building materials, chemicals, mining, pharmaceutical, energy field.IP PROTECTION CLASS:IP 54A3(ORDINARY CARBON STEEL) PLUS SPRAY.SKZ111J INFRARED ONLINE MOISTURE ANALYZER5-BEAMINFRARED MOISTURE ANALYZERPACKING AND TRANSPORTATIONAbout SKZ1. SKZ Industrial Co. Limited and SKZ International Co., LTD are members of the SKZ group.
Contact Now
SKZ1018B Karl Fischer Moisture Water Content Test AnalysisIt is auto-analyzer used Karl Fischer titration method,determination moisture content.Standards:ISO 10337,ASTM D 1744, ISO 760 , ASTM E203Technical parameters:Measuring range3ppm-100% Resolution0.01mlMoisture titration Repeatability≤ 0.01Moisture titration linear correlation coefficient≥ 0.998Capacity error≤ ± 0.002Burette capacity>25mlSensitivity10-6ASKZ1018B VOLUMETRIC KARL FISCHER TITRATIONCan be realized:solvent inhalation,determination,enddisplay (alarm),waste water discharge,mixing by means of itsfunction keys.Complete a
Contact Now
Microscopic Thermal Analyzer SKZ1040A-1Be used as the melting point of trace samples for determination, but also for biological engineering thermodynamics research in medicine, chemical, synthetic fiber, biology, mineralogy, criminology. Feature1.Using PWM pulse program to control temperature and color touch screen display.2.With 3000 sets of test data storage.3.
Contact Now
TGA Thermo Gravimetric Analyzer SKZ1053Product descriptionThermo gravimetric analysis (TG, TGA) is to observe the change of sample quality with temperature or time in the process of heating and constant temperature, the purpose is to study the thermal stability and composition of the material. Widely used in the research and development, process optimization and quality control of plastics, rubber, coatings, pharmaceuticals, catalysts, inorganic materials, metal materials and composite materials. Technical parametersTemperature rangeActual maximum temperature 1150℃(S
Contact Now
DTA Differential Thermal Analyzer SKZ1055Differential thermal analysis: temperature under program control, the relationship and difference of temperature between the measured material and the reference.The DTA curves is to describe the changing relationship depending on temperature and time between the measured material and the reference compound. During the test, the sample temperature changes due to the phase change or an endothermic or exothermic reaction effects.
Contact Now
SKZ1062B Dry method laser particle size AnalyzerSpecifications1, measuring range: 0.1 to 800 microns 2. Accuracy: <± 1% (national standard D50) 3. Repeatability: <± 1% (national standard D50) 4, Power: AC 220 ± 10V, 50Hz, 200W 5. Dimensions: Host: 1000 × 330 × 300mm, dry injection system: 350 × 330 × 300mm 6, Weight: 40KG Dispersion method System includes a laser particle size analyzer, automatic dry dispersion system, composed of Silent oil free air compressor, high efficiency condenser section.
Contact Now
SKZ1060 Lab Synchronous Thermal AnalyzerSimultaneous thermal Analyzer STA is a mixture of differential heating and thermo gravimetric .
Contact Now
SKZ1053 Thermal Gravimetric AnalyzerWhen heating a material to look into its composition and thermal stability, thermogravimetric analysis (TG, TGA) is used to monitor changes in sample quality over time or at various temperatures.widely utilized in the development, manufacturing, quality assurance, and process optimization of polymers, rubber, coatings, medicines, catalysts, inorganic, metal, and composite materials.Uses: oxidation and reduction, breakdown process, moisture and volatiles, reaction kinetics, additions and fillers, adsorption and desorption, and quantitative component anal
Contact Now
It is auto-analyzer used Karl Fischer titration method,determination moisture content.Standards:ISO 10337,ASTM D 1744, ISO 760 , ASTM E203Features:1. New speed drop function, use automatic control electrode polarization voltage drop speed, measure a sample requires only tens of seconds2. Additional current meter makes the titration process more intuitive3. Entire fluid path is made of special materials selection, excellent corrosion resistance, to ensure long-term continuous operation4.
Contact Now
Used for testing the stiffness of all kinds of woven and knit goods, nonwoven fabrics and coated fabrics, including cotton, wool, silk, linen and chemical fiber, and also of flexible materials such as paper, leather, filmRelevant Standards:ZB WO4003, ISO 9073, ASTM D 1388, ISO9073-7, BS En22313Warranty1 yearCustomized supportOEMPlace of OriginChinaShandongBrand NameSKZWorking patternMicro-computer controlled, infrared stealth slant detecting, liquid crystal display, printing out testing resultsTesting range40.5, 43, 45( adjustable)Extension elongation0.5-20.5cmTesting accuracy0.01 cmSpecimen s
Contact Now
SKZ1018B Volumetric Karl Fischer TitrationIt is auto-analyzer used Karl Fischer titration method,determination moisture content. Standards:ISO 10337,ASTM D 1744, ISO 760 , ASTM E203Features:1. New pace drop function, use computerized manage electrode polarization voltage drop speed, measure a pattern requires solely tens of seconds2. Additional cutting-edge meter makes the titration procedure extra intuitive3.
Contact Now
SKZ1018B Efficient Moisture Volumetric Titration EquipmentThe SKZ1018B represents an advanced auto-analyzer that harnesses the Karl Fischer titration methodology for precise moisture content determination, adhering to renowned international standards such as ISO 10337, ASTM D 1744, ISO 760, and ASTM E203.
This state-of-the-art instrument comes packed with a suite of unique features designed to enhance performance and user experience:
1. A revolutionary speed drop mechanism has been implemented, which leverages automated control of the electrode polarization voltage drop pace.
Contact Now
STA Synchronous Thermal Analyzer SKZ1060ASimultaneous thermal analysis (DSC/DTA, TGA) is a combination of differential heating and thermo gravimetric . It can not only study the change of sample quality with temperature or time in the process of heating and constant temperature, but also study and analyze the change process of the sample, by the heat generated changes.
Contact Now