Plastic Five points Heat Seal EquipmentFive-point heat-seal Tester (also known as gradient heat seal tester) can be used to determine the heat sealing temperature range , suitable packaging speed, and heat sealing pressure of the plastic film substrate, the flexible packaging composite film, coated paper and other heat sealing composite membrane.
Contact Now
SKZ1017B Plastic Five points Heat Seal EquipmentThe Five-point heat-seal Tester, alternatively referred to as the gradient heat seal tester, is an instrument capable of establishing the optimal heat sealing temperature range, ideal packaging speed, and required heat sealing pressure for various materials such as plastic film substrates, flexible packaging composite films, and coated paper, which are all heat-sealable composite membranes.Structure:Divided into 4 components of the air force system, warmth sealing device, temperature manage system
Contact Now
SKZ1017B Five points Heat Seal TesterStructure:Divided into 4 components of the air power system, warmness sealing device, temperature manage system, time-conditioning systems.1. Structure: It contains air drive system, sealing devices, temperature-conditioning systems, time-conditioning systems2. Air-driven system: Including pressure gauges, guide rods, cylinder, pneumatic valve, pressure regulator handles, so on.
Contact Now
SKZ1017B Five point heat sealing apparatusThe Five-point heat-seal Tester, also known as the gradient heat seal tester, is a versatile tool used to determine various parameters related to heat sealing. It can be used to determine the heat sealing temperature range, suitable packaging speed, and heat sealing pressure of different materials such as plastic film substrates, flexible packaging composite films, coated paper, and other heat sealing composite membranes.
Contact Now
Five-point heat-seal Tester (also known as gradient heat seal tester) can be used to determine the heat sealing temperature range , suitable packaging speed, and heat sealing pressure of the plastic film substrate, the flexible packaging composite film, coated paper and other heat sealing composite membrane. It can also work with tensile tester to do heat seal strength test. Structure: Divided into four parts of the air drive system, heat sealing device, temperature control system, time-conditioning systems. 1).
Contact Now
Be measured heat sealing temperature range of sealing compound, heat sealing strength, hot package of speed, heat sealing pressure, used for plastic, flexible packaging composite membrane, coated paper, foil. 1. Structure: It contains air drive system, sealing devices, temperature-conditioning systems, time-conditioning systems2. Air-driven system: Including pressure gauges, guide rods, cylinder, pneumatic valve, pressure regulator handles, so on.
Contact Now
SKZ143 Accelerated ageing and heat resistance testsStandard:ISO 188-- Rubber, vulcanized or thermoplastic--Accelerated ageing and heat resistance tests--Air-oven method.Technical parameters:The highest temperature200℃ (A type) , 300℃ (B type)Temperature fluctuation±1℃Turntable speed12r/minDimension of working room450×450×450 mmRated power2.2KWPowerAC220V, 50HZDimension870×660×1350 (mm)Net weight180kgTEMPERATURE CONTROLLED BYDIGITAL DISPLAYPOWVEFWORKING TEMPERATURE:FROM ROOM TEMPERATURE TO200℃ (A TYPE) OR 300'℃ (B TYPE)DIMENSION OF WORKING ROOM:450x450x450 MMPID AUTO ADJ
Contact Now
SKZ1050E C6H14 Hexane Combustion Gas Detecting Instrument Potable Best Gas Leak DetectorThe SKZ1050E has a 150-degree wide viewing angle, a 3.5-inch high-definition IPS LCD colour screen, and an optional fall warning feature. One or more gas sensors can be added as needed, and an optional fall alarm feature increases operator safety even more.
Contact Now
Suitable for all kinds of film, shrink film, heat shrink pipe, back plate. Such as the overall collection of various beverage packaging shrink film, shrink packaging film for medical packaging. Testing of the heat shrinking properties in a liquid medium at various temperatures.
Contact Now
TU1000 Turbidity Measurement InstrumentGENERAL FEATURESLED light source at 850 nm.leverages the 90° detection concept of nephelometry.Complies with ISO 7027 and provides a steady light source for improved precision.Variable turbidity units, such as the EBC, FNU, and NTU.Configurable parameters, such as the user ID, data and time, number of calibration points, etc.High precision is ensured by two photodiodes.Calibration from 1-6 points utilizing zero water or Formazin standards.Autoranging between 0 and 1000 NTU.Up to 2000 sets of data can be stored (GLP-compliant).The computer may receive
Contact Now
PH310F pH MeterFeatures:LCD display screen, 3.5 inches.Multi-reading feature allows auto-read, timed-read and continuous-read. Automatic/Manual temperature compensation ensures accurate results. Auto-hold feature senses and locks the measurement endpoint.Data capacity of up to 500 sets for each parameter (GLP-compliant).Support for USB communication.Auto-power off feature effectively extends the battery service life.Reset feature automatically resumes all settings back to factory default options.IP65 waterproof.
Contact Now
The drying oven can provide drying, baking, sterilization and heat treatment. Stainless steel tank and digital display, its working temperature can reach to the highest point from room temperature, which can also be adjusted arbitrarily.
Contact Now
SKZ1043B Potentiometric Titration InstrumentApplication: Often utilized in petrochemical, quality control, food additives, food safety, pharmaceutical manufacturing, and research facilitiesFeatures:1.The convenient automatic titration system and integrated titrator with a small design Burette valves are easy to change, have an integrated design, and prevent multiple titrations and solution interference. b) Automatic identification of the pH standard solution groups (groups 1:4.00, 6.86, 9.18, and group 2:3.78, 7.00, 10.01, and pH) complements manual identification.
Contact Now
SKZ XRY-1A+ Oxygen Bomb Calorimeter Description In ChemistryI. SummaryThe instrument is designed and made as per the National Standard of People’s Republic of China GB/T213-2008 and ASTM D240 Test Method for Calorific Value of coal, GB/T384-1988 Test Method for Calorific Value of Petroleum Products and Calibration Regulation of People’s Republic of China JJG672-2001 Oxygen Bomb CalorimeterII. Main technical specifications1. Power supply: AC 220V±5%, 50 Hz2. Total power consumption: ≤150W.3. Heat capacity: (14000~15000) J/K4. Resolution: 0.001 K5.
Contact Now
Leak Tester is a kind of tester that use compression air to produce negative pressure by vacuum device to test the seal capability and processing technique of soft plastic packaging material in food and pharmaceutical industry. It also can test the specimen which has done the drop and compression test. Standards GB/T15171-94 (the Seal Testing Method for soft packaging).
Contact Now
SKZ1059B Carbon Black Content Testing Instrument
This tester is designed to determine the carbon black content in polyethylene, polypropylene, and polyisobutylene plastics.
Standards:
It complies with ISO 6964 for the determination of carbon black content in polyethylene pipes and fittings via calcination and pyrolysis, ASTM D1603 for testing carbon black content in olefin plastics, and IEC 60811-4-1 for common test methods of insulating and sheathing materials of electric and optical cables, specifically for polyethylene and polypropylene compounds.
Features:
1.
Contact Now
TPS Thermal Conductivity Meter SKZ1061CProduct detailIt can be used for various heat conduction properties of different types of materials testing. Transient Plane Source method is to study the thermal conductivity method, the latest one, which makes measurement technology to a whole new level. In the study of material capable of fast and accurate measurement of thermal conductivity for the enterprise quality control, material production and laboratory studies provide a great convenience. The instrument is easy to operate, simple to understand, will not cause damage to
Contact Now
SKZ145A Melt Flow Indexer MFR instrumentTechnical parameters:Test methodMFR (unit: g / 10min)Temperature rangeroom temperature ~ 300 ℃Temperature accuracy± 0.5 ℃Temperature Resolution0.1 ℃Measuring range0.1 ~ 300g / 10min (MFR)load3.187 ~ 211.82N is divided into eightBarrel diameterф9.55mm ± 0.025mmDie apertureΦ2.095 ± 0.005mmPowerAC220V±10% 50Hz 1kWDimension300mm×400mm×500mmWeight35kg ABOUT USSKZ Industrial Co., Limited and SKZ International Co., Limited are the humans of SKZ, which are specialised in furnish rubber attempting out machine.SKZ installed 
Contact Now
Used to carry the heat-ageing test for plasticity material, insulation material. Temperature controlled by digital display, PID auto adjustment, can arbitrarily set the working temperature from room temperature to 200℃ or 300℃, automatically keep temperature.
Contact Now
SKZ104B Paper Bekk Smoothness Tester Testing MachineMain Features1.Imported oil-free vacuum pump2.Fast measurement: with small volume chamber measurement, which measurement time is only one-tenth of a large one, saving time in measurement. And the function of “automatic test" has been added, can greatly save time when testing high smoothness 3.Good seal: adopted foreign vacuum sealed plastic and advanced sealing technology to achieve the national standard requirements;4. Adopted 7.0 inches color touch-screen which makes it easy to operate.5.
Contact Now
SKZ1052C-1L Differential Scanning Calorimeter360° lab and factory: https://skztester.en.alibaba.com/company_profile.html?spm=a2700.shop_oth.8.9DSC Video: https://youtu.be/m9z9fUnwLvg DSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control.
Contact Now
DSC is widely utilized in the fields of polymer research, performance testing, and quality control. It is intended to identify the inner heat transition in relation to temperature and heat flow. The fields of glass transition temperature, melting point, cold crystallization, phase transition, and oxidation induction time (OIT) are all included in DSC study and development.Standards:ISO/TR10837:1991, ASTM D3895-1998, ASTM E 967, ASTM E 968, ASTM E 793, ASTM D 3895, ASTM D 3417, ASTM D 3418, ISO 11357-6Features: 1. Rich information is shown on an industrial-grade 7-inch touch screen.2.
Contact Now
DSC Differential Scanning Calorimeter SKZ1052Product descriptionDSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control.
Contact Now
SKZ1052 differential scanning calorimetry dsc analysisPerformance testing, quality control, and polymer research all make extensive use of DSC.The goal is to determine how temperature and heat flow relate to the inner heat transition.DSC research and development encompasses the domains of glass transition temperature,melting point, phase transition, cold crystallization, and ox
Contact Now