Plastic Five points Heat Seal EquipmentFive-point heat-seal Tester (also known as gradient heat seal tester) can be used to determine the heat sealing temperature range , suitable packaging speed, and heat sealing pressure of the plastic film substrate, the flexible packaging composite film, coated paper and other heat sealing composite membrane.
Contact Now
SKZ1017B Five points Heat Seal TesterStructure:Divided into 4 components of the air power system, warmness sealing device, temperature manage system, time-conditioning systems.1. Structure: It contains air drive system, sealing devices, temperature-conditioning systems, time-conditioning systems2. Air-driven system: Including pressure gauges, guide rods, cylinder, pneumatic valve, pressure regulator handles, so on.
Contact Now
SKZ1017B Plastic Five points Heat Seal EquipmentThe Five-point heat-seal Tester, alternatively referred to as the gradient heat seal tester, is an instrument capable of establishing the optimal heat sealing temperature range, ideal packaging speed, and required heat sealing pressure for various materials such as plastic film substrates, flexible packaging composite films, and coated paper, which are all heat-sealable composite membranes.Structure:Divided into 4 components of the air force system, warmth sealing device, temperature manage system
Contact Now
SKZ1017B Five point heat sealing apparatusThe Five-point heat-seal Tester, also known as the gradient heat seal tester, is a versatile tool used to determine various parameters related to heat sealing. It can be used to determine the heat sealing temperature range, suitable packaging speed, and heat sealing pressure of different materials such as plastic film substrates, flexible packaging composite films, coated paper, and other heat sealing composite membranes.
Contact Now
Five-point heat-seal Tester (also known as gradient heat seal tester) can be used to determine the heat sealing temperature range , suitable packaging speed, and heat sealing pressure of the plastic film substrate, the flexible packaging composite film, coated paper and other heat sealing composite membrane. It can also work with tensile tester to do heat seal strength test. Structure: Divided into four parts of the air drive system, heat sealing device, temperature control system, time-conditioning systems. 1).
Contact Now
Be measured heat sealing temperature range of sealing compound, heat sealing strength, hot package of speed, heat sealing pressure, used for plastic, flexible packaging composite membrane, coated paper, foil. 1. Structure: It contains air drive system, sealing devices, temperature-conditioning systems, time-conditioning systems2. Air-driven system: Including pressure gauges, guide rods, cylinder, pneumatic valve, pressure regulator handles, so on.
Contact Now
SKZ143 Accelerated ageing and heat resistance testsStandard:ISO 188-- Rubber, vulcanized or thermoplastic--Accelerated ageing and heat resistance tests--Air-oven method.Technical parameters:The highest temperature200℃ (A type) , 300℃ (B type)Temperature fluctuation±1℃Turntable speed12r/minDimension of working room450×450×450 mmRated power2.2KWPowerAC220V, 50HZDimension870×660×1350 (mm)Net weight180kgTEMPERATURE CONTROLLED BYDIGITAL DISPLAYPOWVEFWORKING TEMPERATURE:FROM ROOM TEMPERATURE TO200℃ (A TYPE) OR 300'℃ (B TYPE)DIMENSION OF WORKING ROOM:450x450x450 MMPID AUTO ADJ
Contact Now
Suitable for all kinds of film, shrink film, heat shrink pipe, back plate. Such as the overall collection of various beverage packaging shrink film, shrink packaging film for medical packaging. Testing of the heat shrinking properties in a liquid medium at various temperatures.
Contact Now
The drying oven can provide drying, baking, sterilization and heat treatment. Stainless steel tank and digital display, its working temperature can reach to the highest point from room temperature, which can also be adjusted arbitrarily.
Contact Now
Leak Tester is a kind of tester that use compression air to produce negative pressure by vacuum device to test the seal capability and processing technique of soft plastic packaging material in food and pharmaceutical industry. It also can test the specimen which has done the drop and compression test. Standards GB/T15171-94 (the Seal Testing Method for soft packaging).
Contact Now
SKZ1053 High Pressure Automatic Thermogravimetric Analysis LabThermo gravimetric evaluation (TG, TGA) is to look at the exchange of pattern high-quality with temperature or time in the manner of heating and consistent temperature, the motive is to find out about the thermal balance and composition of the material.Widely used in the lookup and development, procedure optimization and satisfactory manipulate of plastics, rubber, coatings, pharmaceuticals, cat
Contact Now
Used to test product packaging for damage and evaluate impact resistance and the transport handling process; mostly used to ensure that product packaging can withstand the circumstances of transport capacity and hence enhance and optimize packaging design.Standard:ISO2248, JISZ0202-87Qualities:With a digital height indicator and height tracking decoder, a single wing drop tester may perform a free drop test of the package's surface, angle, and edge.
Contact Now
High and low temperature test chamber is one of the climate simulation chambers for the assessment of various electronic products, test at high temperature, low temperature environment.Features:1.Unique balance thermostat, high precision, high temperature stability control.2.Temperature controller with high precision, high stability, PID self-tuning, LED visual display, to ensure precise control of equipment. Equipment with over-temperature3.
Contact Now
SKZ1061C Thermal Conductivity Testing Equipment**
The SKZ1061C Thermal Conductivity Testing Equipment is an outstanding testing instrument that employs the advanced Transient Plane Source (TPS) technique.
Contact Now
SKZ1015 Vacuum Drying ChamberThe drying oven is capable of heat treatment, baking, sterilizing, and drying. Its digital display and stainless steel tank allow it to operate at a temperature that can be freely adjusted to the maximum point from room temperature.Technical parameters:voltage220V 50HzTemperature control rangeRT+10℃~250℃Temperature resolution0.1℃Constant temperature fluctuation±1℃input power1120WWorking temperature5℃~40℃Liner size (mm)420×400×345Dimensions (mm)720×580×530Load carrier (standard)2pcsTiming range1~9999 minutes
Contact Now
SKZ1052 differential scanning calorimetry dsc analysisPerformance testing, quality control, and polymer research all make extensive use of DSC.The goal is to determine how temperature and heat flow relate to the inner heat transition.DSC research and development encompasses the domains of glass transition temperature,melting point, phase transition, cold crystallization, and ox
Contact Now
Used to carry the heat-ageing test for plasticity material, insulation material. Temperature controlled by digital display, PID auto adjustment, can arbitrarily set the working temperature from room temperature to 200℃ or 300℃, automatically keep temperature.
Contact Now
SKZ1062E Spray Laser Particle Size AnalyzerScopeIt is suitable for the detection of droplet size in small spray equipment such as medical nebulizers, atomized medicines, various aerosols and sprays. Feature1.Compact, portable achieve a real sense in the field of particle size analyzer2.Advanced integrated structural design, more stable3.Optical path combines advanced dust-proof design, without the need for secondary adjust the optical path, greatly improving test efficiency1. Advanced light path design:It adopts the Fraunhofer diffraction principle and typical parallel o
Contact Now
SKZ125 Rapid-kothen Sheet Former Paper Sheet Making Test MachineFeature: 1.Mainly composed by dryers, vacuum pumps, and sheet former (press)2.Sheet former parts: power-driven drain off water, white water cycle use, power-driven feed water, aerodynamic homogenate ( also can manual homogenate), Water molding or vacuum pump suction molding3.Dry parts adopt vacuum heating and drying, vacuum pump adopts water cycle, heating element use heating plate, temperature control system, and has a short circuit, disconnection, and automatic over-temperature alarm function, with a stop anti-oil
Contact Now
DSC is widely utilized in the fields of polymer research, performance testing, and quality control. It is intended to identify the inner heat transition in relation to temperature and heat flow. The fields of glass transition temperature, melting point, cold crystallization, phase transition, and oxidation induction time (OIT) are all included in DSC study and development.Standards:ISO/TR10837:1991, ASTM D3895-1998, ASTM E 967, ASTM E 968, ASTM E 793, ASTM D 3895, ASTM D 3417, ASTM D 3418, ISO 11357-6Features: 1. Rich information is shown on an industrial-grade 7-inch touch screen.2.
Contact Now
Salt spray corrosion test chamber is one of the three test facilities for artificial climate, such as Wet- heat, salt spray and mould.
Contact Now
Laboratory Rotary Digester Testing EquipmentFeatures1. Versatility: It is designed for caustic cooking and acid cooking, and can also be used for cooking and bleaching of other liquidswith a work pressure not exceeding 8Kg/cm². This versatility allows it to be used in a wide range of chemical processes.2. Durable Construction: The device is primarily composed of high-quality stainless steel, which ensures high corrosion resistance and longevity.3.
Contact Now
SKZ148 Drop Dart Impact TesterThe impact resistance of plastic films and sheets is tested using a dart impact testing equipment, which uses a background light source to record test findings.StandardISO7765-85, GB9639-88, ASTM D1709 - 09 Technical parametersDart-head weight50-2000g, 5g/incremental (5g*5pcs,15g*15pcs, 30g*10pcs, 45g*10pcs, 80g*10pcs, 90g*15pcs)Dart-head semi-diameterA method: R19±1mm,B method: 25±1mmDart-head accuracy0.1%Impact height660mm, 1500mmImpact energy30JSample clamp deviceexternal dia.: 150mm, inside dia.: 125mmWorking t
Contact Now
DSC Differential Scanning Calorimeter SKZ1052Product descriptionDSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control.
Contact Now