Product descriptionSuitable for measuring the moisture content of waste paper bales, straw, wheat straw,forage, hay, sugar cane waste, corn stalks, corn silage, reeds, bamboo,abaca, tobacco leaf, botanicals, fern stalks. Product ParameterDisplay LCD disply Measuring range0 ~ 80%Resolution0.1%Accuracy0%-10%: ±0.2%10%-40%: ±0.5%40%-80%:±1%Probe 600mm Power 9V battery*1Dimesion 160mm × 60mm × 27mmNet weight/gross weight 250g/1kg Package size 610 X 110 X 170 mmApplicationSuitable for measuring the moisture content of waste paper bales, straw, wheat straw, forage, ha
Contact Now
Portable Handheld Hay Moisture Tester HygrometerFeature Using high-frequency principle, frequency more than 10MHZSensor probe is 316L steel + PTFE, it is corrosion, wear resistantWith 10th measurement switch stalls.
Contact Now
SKZ111D Digital Waste Paper Bales Moisture Meter Hay Straw Moisture Tester AnalyzerPortable hay moisture meter for accurate and efficient moisture measurement. Ideal for agricultural and recycling industries.Suitable for measuring the moisture content of waste paper bales, straw, wheat straw, forage, hay, sugar cane waste, corn stalks, corn silage, reeds, bamboo,abaca, tobacco leaf, botanicals, fern stalks.Display LCD disply Measuring range0 ~ 80%Resolution0.1%Accuracy0%-10%: ±0.2%10%-40%: ±0.5%40%-80%:±1%Probe 600mm Power 9V battery*1Dime
Contact Now
SKZ107A Elmendorf Tear TesterIt is a specialized tool used to measure the strength of paper tears.
Contact Now
SKZ1053 Automatic Thermo GravimetricAnalysis Tga PriceThermo gravimetric evaluation (TG, TGA) is to examine the exchange of pattern exceptional with temperature or time in the technique of heating and regular temperature, the reason is to learn about the thermal balance and composition of the material.Widely used in the lookup and development, procedure optimization and excellent manage of plastics, rubber, coatings, pharmaceuticals, catalysts, inorganic materials, steel substances and composite substancesController and software program advantages:1.
Contact Now
ABBE Digital Refractometer SKZ1019AABBE Digital Refractometer, Automatic correction of the effect of temperature on the Brix. Visual aim Feature1. Measurement of refractive index nD of transparent or translucent liquid and solid substances.2. Measurement of the Brix of sugar solution. 3. Visual aim and LCD display 4. Automatic correction of the effect of temperature on the Brix.5.
Contact Now
SKZ1019 Digital Brix RefractometerCharacteristics: Use the refraction design principleElectronic DisplaySmall enough to tuck into a pocket.Quick and simple: all it takes is a drop of the sample solution on the prism to get readings in about three seconds.Often used to measure liquid foods and beverages, including practically any fruit juice.Sample volume0.3mlResponse time3sUse lifemore than 10,000 timesTemperature measure range0°C-40°C(32°F-104°F)Accuracy of temperature±0.5°C(1°F)Automatic temperature compensation10°C-60°CAutomatic power-offYesBattery power shortage alarmYesPower Supply2×
Contact Now
I300F Benchtop Ion MeterSupport for USB or RS-232 communication. Reset feature automatically resumes all settings back to factory default options. IP54 waterproof.PRODUCT SPECIFICATIONSModelI300FParameterspH/ISE/Temp.(mV/pX)pHRange-2.00 to 20.00 pHResolution0.1, 0.01 pHAccuracy±0.01 pHmVRange-2000.0 to 2000.0 mVResolution0.1, 0.01 mVAccuracy±0.1 mV or ±0.03% of reading whichever is greaterpXRange-2.00 to 20.00 pXResolution0.1, 0.01 pXAccuracy±0.01 pXCalibration PointsUp to 5ISERange1.000e-9 to 9.999e+9Unitmol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppbResolutionUp to 4 significant digitsAcc
Contact Now
DO400F dissolved oxygen testerGENERAL FEATURESHigh resolution LCD display, 5.7 inches.Multi-reading feature allows auto-read, timed-read and continuous-read. Automatic/Manual temperature compensation ensures accurate results.
Contact Now
SKZ XRY-1A Automatic Oxygen Bomb Calorimeter For Coal AnalysisIt is suitable to determine calorific value of combustible materials such as petroleum products without water (gasoline, jet fuels, diesel oil and fuel oils, etc.), coal, coke and paraffin, etc.Main technical specifications1. Heat capacity: 14400 J/K~15000 J/K2. Resolution: 0.001 K3. Measurement accuracy: ± 60J/g4. Repeatability: ≤0.2% (Grade C)5. Pressure endurance of oxygen bomb: 20 MPa6. Temperature measurement range: 10 ℃~35 ℃7.
Contact Now
SKZ165 Martindale Pilling TesterUsed to evaluate how well textiles and membrane materials perform in terms of wearing resistance, abrasion, and appearance change (pilling degree/class).Standards:ASTM D4970,ASTM D4966,ISO12947,JIS L1096,TM112 M&S, FZ/T20020,IWS TM196,ASTM D3886,DIN53863/53865, BS3424/5690,BS EN 388/530,ISO12945-2Test mode:Mode 1: Using a circular specimen made of the same material fabric and friction with a Lissajous graphic motion trajectory, the specimen can reach the necessary speed while assessing sample pilling at a certain pressure.
Contact Now
DSC Differential Scanning Calorimeter SKZ1052Product descriptionDSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control.
Contact Now
SKZ-1052 DSC Test Differential Scanning Calorimeter For LabDSC is designed to decide the internal warmth transition touching on to temperature and heat flow, it is extensively used in the area of polymer development, overall performance trying out & first-rate control.
Contact Now
SKZ1052 Dsc Differential scanning calorimetry InstrumentsMain Features:1. The industrial-grade 7-inch contact show display screen suggests affluent information.2. Brand-new metal furnace physique structure, with greater baseline and increased accuracy. The heating adopts indirect conduction method, which has immoderate uniformity andstability, reduces pulse radiation, and is greater than general heating mode.3. USB dialog interface, sturdy versatility, reliable and uninterrupted communication, helps self-recovery connection function.4.
Contact Now
SKZ1052 Differential Scanning Calorimeter (DSC)Performance testing, pleasant control, and polymer lookup all make full-size use of DSC.The purpose is to decide how temperature and warmth glide relate to the internal warmth transition.DSC lookup and improvement encompasses the domains of glass transition temperature,melting point, segment transition, bloodless crystallization, and oxidation induction time (OIT).Features:1.
Contact Now
SKZ1064 Oxygen Bomb CalorimeterOxygen bomb calorimeter can be used to measure the calorific value of solid or liquid samples, measuring samples in a closed container (oxygen bomb), oxygen-filled environment, the heat generated by combustion, the measurement results called the combustion value, calorific value , BTU and so on. Calorific value results have the value of determining other values to determine the quality of the sample as a basis for calculating the price (eg, coal), as well as physiology (eg, energy distribution in ecology, energy metabolism in animal nutrition studies, etc.),
Contact Now
Digital Oxygen Bomb Calorimeter SKZ1064Oxygen bomb calorimeter can be used to measure the calorific value of solid or liquid samples, measuring samples in a closed container (oxygen bomb), oxygen-filled environment, the heat generated by combustion, the measurement results called the combustion value, calorific value , BTU and so on.Calorific value results have the value of determining other values to determine the quality of the sample as a basis for calculating the price (eg, coal), as well as physiology (eg, energy distribution in ecology, energy metabolism in animal nutrition studies, etc.
Contact Now
SKZ1013 Surface Tension MeasurementThe small design of the automatic surface tensiometer, which consists of a microcomputer control system, a platinum plate (ring) measurement device, and a highly precise and stable force measurement system, makes it easy to operate both manually and automatically.
Contact Now
SKZ1050B Fixed HCHO Monitor Gas Detection Equipment 0-100PPM Formaldehyde CH2O Fixed Gas DetectorFunction 1.Environmental monitoring or GAS pipeline concentration and alarm2.Temperature compensation can be used to create the ideal conditions for varying gas concentration temperatures. 3.It is possible to remotely control infrared devices without having to open the alarm set point, zero calibration, change the address, or do other tasks. SpecificationsGas DetectedCH2ODetection principleElectrochemical principlesSampling MethodWall-mounted, pipeline, flow typeMeasure Range0-1
Contact Now
Product DetailsThe SKZ1050-O2 oxygen gas detector appears to be a versatile device that can both ensure the safety of oxygen concentrations in the factory environment and can be used to protect the health of employees. The function of this gas detection instrument is suitable for both industrial production environments and personnel safety monitoring.
Contact Now
SKZ1043 Automatic Potentiometric TitratorUsed for the detection of index with plausible ability analysis, can be used as extraordinary instrument for the detection of penicillin, by means of measuring the alternate in electrode potential, to measure the ion concentration, extensively used for the pharmaceutical industry, meals industry, petrochemical industry, metallurgy, environmental protection, electroplating substances industry.Main functions1.Titration type of chemical reaction: acid-base titration, redox titration
Contact Now
Laboratory PFI Beater For beating test of middle and high concentrations pulps, so that to Analysis of high-grade paper. Principle:Placed the pulps, which is measured having a predetermined concentration, between the knife roller and the beating cylinder, rotating with different circumferential speeds. In order to achieve the purpose of beating pulp. Features:1. Main components made of stainless steel,2. Pulp pool with a knife roller are regulated speeds, belt drive,3. The counter can be set to the number of revolutions dissociation pulp,4.
Contact Now
Volumetric Karl Fischer Titration SKZ1018BIt is auto-analyzer used Karl Fischer titration method,determination moisture content.Standards:ISO 10337,ASTM D 1744, ISO 760 , ASTM E203Features:1. New speed drop function, use automatic control electrode polarization voltage drop speed, measure a sample requires only tens of seconds2. Additional current meter makes the titration process more intuitive3. Entire fluid path is made of special materials selection, excellent corrosion resistance, to ensure long-term continuous operation4.
Contact Now
SKZ1018B Karl Fischer Volumetric TitrationKarl Fischer titration method is utilized by the auto-analyzer to determine moisture content.Standards:ISO 10337,ASTM D 1744, ISO 760 , ASTM E203Qualities:1.A new speed drop function that measures a sample in tens of seconds using automatic control electrode polarization voltage drop speed2.Having an extra current meter makes the titration procedure easier to understand.3.Specially selected materials with exceptional corrosion resistance make up the whole fluid route, ensuring long-term continuous operation.4.The termination titration, which uses
Contact Now