Analytical Electronic Balance SKZ-A 1.Using high-precision electromagnetic force balance sensor, more accurate, faster response, less fault.2.Weighing faster, and speed adjusted3. Weight units can be converted4. With counting function5. With Tared, cleared, accumulated, overloaded, under load display, fault alarm6. Built-in RS-232 interface, with the printer, computer connected ParametersModel SKZ-A1004SKZ-A 1104SKZ-A 1204SKZ-A 2004SKZ-A 2104SKZ-A 2204Max.
Contact Now
SKZ-C Precision Electronic BalanceFeature* Stainless steel weighing pan* Tare, counting function* LCD wide viewing angle* g, oz, ct unit conversion* Minimum scale weighing*Battery built-in*Windshield (optional)* RS232 interface (optional)Technical ParametersModel SKZ-C1102SKZ-C2102SKZ-C3102SKZ-C5102SKZ-C11002Max capacity 110g210g310g510g1100gResolution 0.01gPan sizeΦ130 mmRepeatability±0.02gLinearity error±0.03gStable time ≤3 secWorking temperature 17.5℃~22.5℃VoltageAC220V /DC6VCalibration External calibrationNet weight 1.5kgGross weight 2.5kgDimension 270*195*65mmPackage size 330*230*135
Contact Now
Digital Density Balance For Gold K Value SKZ400To test density of solid, liquid, powder, water-absorbent sample and Gold K value (A) Feature: 1. High-precision sensor, impact resistance, anti-overload, to ensure weighing accuracy and stability.2. Built-in rigorous test and calculation procedures, direct display density, without manual conversion.3. Aluminum shell, to enhance the anti-static balance anti-interference ability.4. High contrast LCD liquid crystal display, clear and intuitive readings.5.
Contact Now
Digital Density Balance for Emulsions Chemical Solution SKZ300EApplicationsDirect readings, with temperature compensation, and Solution compensation, more humanized operation, suitable for onsite operations.For density determination of Chemical solution, additives, suspensions, emulsions, dispersions, homogeneous type solution, mouthwash, pharmaceutical, and other high viscosity, suspensions, emulsions, colloidal liquid Features1.Direct reading density of liquid, which density> 1 or <12.
Contact Now
Digital Density Balance For Solid Rubber Grain SKZ300A Direct readings, with temperature compensation, and Solution compensation, more humanized operation, suitable for onsite operations.For density determination of rubber, plastic, wire and cable, electrical appliances, sports equipment, tires, glass products, hard alloy, powder metallurgy, magnetic materials, seals, ceramics, sponge, EVA materials, foam materials, alloys, friction materials, New materials, battery materials.Features1. Direct reading density and volume of solid, particles
Contact Now
High and low temperature test chamber is one of the climate simulation chambers for the assessment of various electronic products, test at high temperature, low temperature environment.Features:1.Unique balance thermostat, high precision, high temperature stability control.2.Temperature controller with high precision, high stability, PID self-tuning, LED visual display, to ensure precise control of equipment. Equipment with over-temperature3.
Contact Now
Electronic Brightness Meter SKZ102ABrightness Meter is widely applied in paper and cardboard, pulp, cotton and fabric, plastic, ceramic and porcelain enamel, amylum, construction material, chemical industry, salt making and other testing department that need to test whiteness.Function:1. Test R457 or ISO Brightness.2. Analysis if it contains fluorescent whitening agent and determination of reflection fluorescence.produced by white fluorescent, that is, degree of whitening.3. Test the brightness value of Y10, Ie, the green light diffuse reflectance factor Ry.4.
Contact Now
SKZ1053 Automatic Thermo GravimetricAnalysis Tga PriceThermo gravimetric evaluation (TG, TGA) is to examine the exchange of pattern exceptional with temperature or time in the technique of heating and regular temperature, the reason is to learn about the thermal balance and composition of the material.Widely used in the lookup and development, procedure optimization and excellent manage of plastics, rubber, coatings, pharmaceuticals, catalysts, inorganic materials, steel substances and composite substancesController and software program advantages:1.
Contact Now
Designed according to GB/T1540-1989, ISO535 (Cobb paper and cardboard absorbency method), which is used to test the absorbency of paper and cardboard, but not applied to evaluate the writing capability of paper and cardboard.Technical parameters:Metal cylinder inside area100±0.2cm², height: 50mmAbsorbency paper200~250g/m²Absorbency speed75mm/10minSmooth metal rollerwidth:200±0.5mm, weight:10±0.5kgDimension390×280×410 (mm)Weight 25kgOptional Balance: accuracy 0.001g, measure range 500gStopwatch: 1sGlass graduate: 100ml Cobb sample cutter
Contact Now
SKZ145 Melt Flow Rate TesterMelt mass-flow (MFR) (g/10min), melt volume-flow rate (cm3/10min), and the melt density of thermo resin must be determined for engineering plastics, which have higher melt temperatures, such as polycarbonate, nylon, and fluorine plastics; and for fit for plastics tests, which have lower melt temperatures, such as polyethylene, polystyrene, polypropylene, ABS resin, and poly-formaldehyde resin, etc.Standards:ISO 1133-1, ISO 1133-2, GBT 3682.1-2018, ASTM D1238-2013, ASTM D3364-1999 (2011), JJG878-1994, JB/T5456-2016, DIN53735, UNI-5640Product features:1.The control sy
Contact Now
Product DescriptionDigital Textile Thickness Gauge SKZ185 Used to thickness determination for a variety of woven fabrics, knitted fabricsStandard: GB/T3820, FZ/T01003, ISO5084/9073/9863, ASTM D1777.Features:1. Digital display, with the adoption of electric elevating system, static balancer with a pulley, automatic timer and an electronic dial indicator for reading display.2. Using wear-resistant agate bearing is used as the guider and the rolling bearings are adopted for other transmission countershafts.3.
Contact Now
To determine the melt mass-flow MFR (g/10min), the melt volume-flow rate MFV(cm3/10min) and the melt density of thermo resin, for the engineering plastics of polycarbonate, nylon and fluorine plastics, whose melt temperature are higher, but also fit for the plastics tests of polyethylene, polystyrene, polypropylene, ABS resin and poly-formaldehyde resin, etc, whose melt temperature are lower, widely applied to the fields of plastics materials, product, petrochemical.Standards:ISO 1133-1:2011 Plastics — Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplas
Contact Now
SKZ108C Bursting Strength Of PaperApplicationUsed to detect a range of paper products and thin cardboard layers with a maximum density of 2000 kpa. It may also be used to detect different types of single and multi-layer cardboard, corrugated cardboard, silk cotton, and other non-paper items.StandardsISO2759, ISO 2758. PrincipleIt uses a button for signal transmission.
Contact Now
Products DescriptionHot Selling Yarn Length Tester SKZ193BApplications:By the winder, the sample yarn on the through tube can be winded into skein
yarns with a reel and the reeling tension be measured. It is used to measure a yarn
length, designed for yarn linear density (or count) measurement and skein yarn
strength test. Standard:ISO 2060.2, ISO2060, ASTM D1907, GB4743- 95Features: 1.Timing cog belt of direct transmission, no-lap skid. 2.Countint by optocoupler.
Contact Now
SKZ1053 High Pressure Automatic Thermogravimetric Analysis LabThermo gravimetric evaluation (TG, TGA) is to look at the exchange of pattern high-quality with temperature or time in the manner of heating and consistent temperature, the motive is to find out about the thermal balance and composition of the material.Widely used in the lookup and development, procedure optimization and satisfactory manipulate of plastics, rubber, coatings, pharmaceuticals, cat
Contact Now
SKZ-SY3020/3060 Handheld SpectrophotometerSpecificationModelSKZ3020-Basic versionSKZ3060-Professional versionCaliberSingle Caliber 4mm or 8mmSwitchable caliber 4mm and 8mmSCI SCESCISCI and SCELight typeHigh accuracy full spectrum LEDHigh accuracy full spectrum LED+Dual UVFix positionVisualCamera locationRepeated Accuracy△E≤0.07△E≤0.03Color spaceCIE-Lab, CIE-LCh, Luv, Hunter-Lab, XYZ, Yxy, sRGB, DIN LAB99, CMYK (A/T/E/M/I) Field density, Munsell, Reflectance (bright vision), Blackness, YI yellow, Isochromatic spectrum (light jumping), hiding power, tint/strength/dye
Contact Now
Introduction to Gas DetectorsThe SKZ1050 hydrogen gas detector can be used in the electronic packaging industry because hydrogen gas is mainly used in gas welding. Hydrogen gas detectors can also be used in the metallurgical industry, where hydrogen and copper oxide react to extract purer copper raw materials.Function1. Monitoring of the environment, or the attention of GAS in a constrained house and supply an alarm2. With self-check function, zero calibration function, so that fuel monitoring extra correct and reliable3.
Contact Now
Introduction to H2 gas detectorThe SKZ1050-H2 hydrogen gas detector is mainly used in workplaces where hydrogen gas is present or may occur, such as the electronic packaging industry, food processing industry, metallurgical industry, and other fields. With the increasing emphasis on safety production, equipping gas detectors in places where toxic and harmful gases occur is an issue that cannot be ignored.
Contact Now
SKZ145 Melt Index Tester Mfi TesterFor engineering plastics such as polycarbonate, nylon, and fluorine plastics, whose melt temperatures are higher, as well as fit for plastics tests of polyethylene, polystyrene, polypropylene, ABS resin, and poly-formaldehyde resin, etc., whose melt temperatures are lower, the following parameters must be determined: melt mass-flow (MFR) (g/10min), melt volume-flow rate (cm3/10min), and the melt density of thermo resin.Standards:ISO 1133-1, ISO 1133-2, GBT 3682.1-2018, ASTM D1238-2013, ASTM D3364-1999 (2011), JJG878-1994, JB/T5456-2016, DIN53735, UNI-5640Char
Contact Now
Digital Paper Thickness Tester SKZ106AThe tester is applying to test the thickness of paper and cardboard. Standard:ISO534: Paper and board -Determination of thickness, density and specific volumeISO 438:1980. Paper -- Determination of bulking thickness and apparent densityGB/T451.3: paper and board-Determination of thicknessTechnical Parameters:Measure range0-6mmIndicator display range0-12.7mmAccuracy0.001mm or 0.01mm (paper board)Measuring area200mm²Pressure100 KpaValue error±2.5um or ±0.5%Dimension80×120×120 (mm)Weight5kg
Contact Now
Introduction to Hydrogen AnalyzerHydrogen is a colorless and odorless gas with a very low density. Its applications are very wide, and it can be used in the petrochemical industry to produce ammonia, as well as as as as a reducing agent for refining precious metals. In terms of energy, hydrogen can be used in fuel cells, and hydrogen also has the function of embrittling cream in the food industry. Choosing a good gas detector is very important for gas detection.
Contact Now
LDS-1G Grain Moisture MeterCan measure 33 kinds of grains including coffee beanand cocoa beanHigh PrecisionMoisture Average, Bulk Density Conversion, Weight MeasurementTemperatur EcompensationAC and DC Power SupplyMain function:a. It can weigh material automatically.b. It can be powered off automatically.c. It can adjust temperature automatically.d. It can measure moisture automatically.e. It can correct moisture when empty.f. It has most advanced revising mode.g. The user can decide material kind and revise moisture error.LDS-1G Grain Moisture Meter Detail D
Contact Now
SKZ XRY-1A Automatic Oxygen Bomb Calorimeter For Coal AnalysisIt is suitable to determine calorific value of combustible materials such as petroleum products without water (gasoline, jet fuels, diesel oil and fuel oils, etc.), coal, coke and paraffin, etc.Main technical specifications1. Heat capacity: 14400 J/K~15000 J/K2. Resolution: 0.001 K3. Measurement accuracy: ± 60J/g4. Repeatability: ≤0.2% (Grade C)5. Pressure endurance of oxygen bomb: 20 MPa6. Temperature measurement range: 10 ℃~35 ℃7.
Contact Now
SKZ XRY-1A+ Oxygen Bomb Calorimeter Description In ChemistryI. SummaryThe instrument is designed and made as per the National Standard of People’s Republic of China GB/T213-2008 and ASTM D240 Test Method for Calorific Value of coal, GB/T384-1988 Test Method for Calorific Value of Petroleum Products and Calibration Regulation of People’s Republic of China JJG672-2001 Oxygen Bomb CalorimeterII. Main technical specifications1. Power supply: AC 220V±5%, 50 Hz2. Total power consumption: ≤150W.3. Heat capacity: (14000~15000) J/K4. Resolution: 0.001 K5.
Contact Now