SKZ148 Drop Dart Impact TesterThe impact resistance of plastic films and sheets is tested using a dart impact testing equipment, which uses a background light source to record test findings.StandardISO7765-85, GB9639-88, ASTM D1709 - 09 Technical parametersDart-head weight50-2000g, 5g/incremental (5g*5pcs,15g*15pcs, 30g*10pcs, 45g*10pcs, 80g*10pcs, 90g*15pcs)Dart-head semi-diameterA method: R19±1mm,B method: 25±1mmDart-head accuracy0.1%Impact height660mm, 1500mmImpact energy30JSample clamp deviceexternal dia.: 150mm, inside dia.: 125mmWorking t
Contact Now
Used to test the product packaging by the fall of the damage, and assessment of transport handling process, impact resistance, mainly to meet the product packaging to withstand the conditions of transport capacity, so as to improve and perfect the packaging design. Standard: ISO2248, JISZ0202-87 Features:1 single wing drop tester to do free drop test of the package surface, angle, edge, with digital height indicator and height tracking decoder, which can accurately give the product drop height, and the pre-set drop height error of less than 2%, or 10 mm.2 single wing drop test machin
Contact Now
Falling Hammer Impact Tester SKZ148BUsing Double tube structure, Mainly consists: workbench, Prevent secondary impact mechanism, Hammer, Lifting mechanism, Automatic drop hammer mechanism, Motor, reducer, Electric control box and StandWidely used in a variety of plastic pipe impact resistance of measurement, and also for plates, profiles measured impact. StandardISO 3127, MT-558, ISO 4422 Technical parametersMaximum impact height2000mmHeight positioning error≤ ± 2mmHammer weight0.25 ~ 10.00Kg (0.125Kg / per increment)Optional 15.00KgHammerD25, D90Lift hammer modeAuto (also can hand t
Contact Now
Used to test product packaging for damage and evaluate impact resistance and the transport handling process; mostly used to ensure that product packaging can withstand the circumstances of transport capacity and hence enhance and optimize packaging design.Standard:ISO2248, JISZ0202-87Qualities:With a digital height indicator and height tracking decoder, a single wing drop tester may perform a free drop test of the package's surface, angle, and edge.
Contact Now
Falling ball impact tester is suitable for all kinds of plastic sheet impact test. Standard: ASTM D639-81(1985): STANDARD methods of testing for impact resistance of plats and pats made from engineering plastic rigid plastics by a ball(falling ball) Working principle:On the lift beams, equipped with a control device for controlling the falling ball, release the ball, the impact of the sample, so that to achieve the purpose of testing. Impact energy can be calculated according to the weight and height of the ball.
Contact Now
To determine charpy impact properties of plastics, rigid plastic sheet, pipe, digital type. FeatureHigh precision, easy to use, can be directly calculated impact energy, save 60 historical data, six kinds of units can be switched, display can show the angle and angle peak or energy.
Contact Now
Dart impact testing machine used for plastic films and sheets of impact test to evaluate the impact resistance, it adopts background light source for test results.StandardISO7765-85: Determination for Impact Resistance of Plastic Film and SheetingGB9639-88: Impact Resistance Test of Plastic Films and SheetsASTM D1709 - 09 Standard Test Methods for Impact Resistance of Plastic Film by the Free-Falling Dart MethodTechnical parametersDart-head weight50-2000g, 5g/incremental (5g*5pcs,15g*15pcs, 30g*10pcs, 45g*10pcs, 80g*10pcs, 90g*15pcs)Dart-head semi-diameterA method: R19
Contact Now
SKZ136 Rubber Impact Resilience TesterRubber Impact Resilience Tester is the pendulum impact resiliency tester with energy 0.5J and applied to measure the resilience value of vulcanized rubber with hardness 30—85IRHD. It measures up to ISO4662, ASTM-D 1054-66,DIN 53512. Rubber Impact Resilience Tester is the pendulum impact resiliency tester to measure the resilience value of vulcanized rubber.
Contact Now
ASTM-D 1054-66 Rubber Impact Resilience TesterTechnical parameters:Diameter of impactorФ15mmSpecimen specificationФ29mm×12.5mmImpact weight0.35-0.1kgImpact speed1.4+0.6m/sStrain energy density351+112kJ/m³Resilience value error±0.5%Dimension320mm×200mm×360mmWeight20kgSKZ136IMPACT RESILIENCE TESTEREXCELLENT PERFORMANCE,SUPERB TECHNOLOGYMOQ 1 pCFactory direct saleStandard:1S04662,ASTM-D 1054-66,DIN 535125KPRODUCT DISPLAYNDUSTERubber lmpact Resilience TesterThe instrument is the pendulumimpact resiliency tester to measure the resilience value of vulcanized rubbelSuitable for metallurgy, constructi
Contact Now
SKZ136 Rubber Impact Resilience Tester DIN 53512 MeterTechnical parameters:Diameter of impactorФ15mmSpecimen specificationФ29mm×12.5mmImpact weight0.35-0.1kgImpact speed1.4+0.6m/sStrain energy density351+112kJ/m³Resilience value error±0.5%Dimension320mm×200mm×360mmWeight20kgSKZ136IMPACT RESILIENCE TESTEREXCELLENT PERFORMANCE,SUPERB TECHNOLOGYMOQ 1 pCFactory direct saleStandard:1S04662,ASTM-D 1054-66,DIN 535125KPRODUCT DISPLAYNDUSTERubber lmpact Resilience TesterThe instrument is the pendulumimpact resiliency tester to measure the resilience cost of vulcanized rubbelSuitable for
Contact Now
Used to test the highest temperature called brittleness temperature when the specimen is broken by impact in prescribed conditions.
Contact Now
Digital Internal Plybond Tester SKZ123For testing the Internal Bonding Strength of various paperboards. Standard: TAPPI-UM403.Test principle: the paperboard sample is impact in a certain angle and weight, the energy it has absorbed indicates the internal bonding strength. It could test five samples at one test. The test unit is optional: kg/cm, N/m, J. Feature:1. Mechatronics modern concept design, elegant appearance, easy maintenance.2. Glue pressed hydraulically, the pressure can be adjusted automatically.3.
Contact Now
SKZ133 Rubber Brittleness TesterUsed to test the highest temperature called brittleness temperature when the specimen is broken by impact in prescribed conditions.
Contact Now
Leak Tester is a kind of tester that use compression air to produce negative pressure by vacuum device to test the seal capability and processing technique of soft plastic packaging material in food and pharmaceutical industry. It also can test the specimen which has done the drop and compression test. Standards GB/T15171-94 (the Seal Testing Method for soft packaging).
Contact Now
SKZ Handheld Digital Refractometer Features:1. Adopt principle of refraction design2. Digital readout display3. Portable, fits in your pocket4. Fast and easy: only need a drop of the sample solution, placed on the prism, readings within 3 seconds.5.
Contact Now
Product DescriptionLaboratory Fabric Down Proof Tester SKZ174 Testing the penetration resistance to feather and down of all kinds of textile fabrics.To determine the down-proof properties of fabric, rolling box method.Standards: GB/T12705, FTMS191A (Optional rubber ball)Product Features1. Adopts transparent cylinder as rotary box and has interlayer, can efficiently reduce the noise of balls impact the box.2. High performance motor, box rotate smoothly and stably.3. Box can automatically stop when the rotary number reach the preset value.4.
Contact Now
It is auto-analyzer used Karl Fischer titration method,determination moisture content.Standards:ISO 10337,ASTM D 1744, ISO 760 , ASTM E203Features:1. New speed drop function, use automatic control electrode polarization voltage drop speed, measure a sample requires only tens of seconds2. Additional current meter makes the titration process more intuitive3. Entire fluid path is made of special materials selection, excellent corrosion resistance, to ensure long-term continuous operation4.
Contact Now
SKZ1018B Karl Fischer Volumetric TitrationKarl Fischer titration method is utilized by the auto-analyzer to determine moisture content.Standards:ISO 10337,ASTM D 1744, ISO 760 , ASTM E203Qualities:1.A new speed drop function that measures a sample in tens of seconds using automatic control electrode polarization voltage drop speed2.Having an extra current meter makes the titration procedure easier to understand.3.Specially selected materials with exceptional corrosion resistance make up the whole fluid route, ensuring long-term continuous operation.4.The termination titration, which uses
Contact Now
SKZ1018B Volumetric Karl Fischer TitrationIt is auto-analyzer used Karl Fischer titration method,determination moisture content. Standards:ISO 10337,ASTM D 1744, ISO 760 , ASTM E203Features:1. New pace drop function, use computerized manage electrode polarization voltage drop speed, measure a pattern requires solely tens of seconds2. Additional cutting-edge meter makes the titration procedure extra intuitive3.
Contact Now
Volumetric Karl Fischer Titration SKZ1018BIt is auto-analyzer used Karl Fischer titration method,determination moisture content.Standards:ISO 10337,ASTM D 1744, ISO 760 , ASTM E203Features:1. New speed drop function, use automatic control electrode polarization voltage drop speed, measure a sample requires only tens of seconds2. Additional current meter makes the titration process more intuitive3. Entire fluid path is made of special materials selection, excellent corrosion resistance, to ensure long-term continuous operation4.
Contact Now
SKZ1018B Efficient Moisture Volumetric Titration EquipmentThe SKZ1018B represents an advanced auto-analyzer that harnesses the Karl Fischer titration methodology for precise moisture content determination, adhering to renowned international standards such as ISO 10337, ASTM D 1744, ISO 760, and ASTM E203.
This state-of-the-art instrument comes packed with a suite of unique features designed to enhance performance and user experience:
1. A revolutionary speed drop mechanism has been implemented, which leverages automated control of the electrode polarization voltage drop pace.
Contact Now
Handheld Digital Refractometer SKZ1019Features:1. Adopt principle of refraction design2. Digital Display3. Compact, able to fit into a pocket.4. Fast and easy: only need a drop of the sample solution, placed on the prism, readings within 3 seconds.5.
Contact Now
-80℃~0℃ ISO812 ISO974—80 SKZ133 low temperature Rubber Brittleness EquipmentApplied for non-rigid plastic and other flexible materials at low temperatures and also test the brittleness temperature and low temperature performance for different rubber material or different formula vulcanized rubber. Standard: GB1682-82, ISO812:1991, ISO974—80.Technical parameters:Testing temperature-80℃~0℃Impact speed2 m/s±0.2 m/sImpactor weight200 ± 20gWorking stroke 40 ± 1mmTemperature fluctuation<±0.5℃Distance between impactor and clamp11±0.5 (mm)Distance between i
Contact Now
SKZ1019 Digital Brix RefractometerCharacteristics: Use the refraction design principleElectronic DisplaySmall enough to tuck into a pocket.Quick and simple: all it takes is a drop of the sample solution on the prism to get readings in about three seconds.Often used to measure liquid foods and beverages, including practically any fruit juice.Sample volume0.3mlResponse time3sUse lifemore than 10,000 timesTemperature measure range0°C-40°C(32°F-104°F)Accuracy of temperature±0.5°C(1°F)Automatic temperature compensation10°C-60°CAutomatic power-offYesBattery power shortage alarmYesPower Supply2×
Contact Now