SKZ129B DIN Abrasion TesterFor determination of abrasion resistance of rubber tires, rubber overshoes, adhesive tape, to identify the quality of rubber products. Rubber compounds were friction with the cloth in a certain load to determine the amount of abrasion of the sample within a predetermined stroke.Standard ISO4649, DIN 53516Technical parameters:Sample load2.5N, 5N,10NStroke40m or 20mRoller speed40 ± 1r/minRoller diameterФ150 ± 0.2mmRoller length460mmSample dia.Ф16 ± 0.2mmPowerAC220V ± 10% 50HzDimension700mm × 340mm × 300mmWeight63kg
Contact Now
SKZ129B DIN Abrasion Tester DIN AbraderStandard ISO4649, DIN 53516Technical parameters:Sample load2.5N, 5N,10NStroke40m or 20mRoller speed40 ± 1r/minRoller diameterФ150 ± 0.2mmRoller length460mmSample dia.Ф16 ± 0.2mmPowerAC220V ± 10% 50HzDimension700mm × 340mm × 300mmWeight63kgEXCELLENT PERFORMANCE,SUPERB TECHNOLOGYStainless steel rollerAnti-corrosion and anti-rustThe operation interface is simple and clearStandard: lS04649, DIN 53516PRODUCT DISPLAYSKZ129B is suitable for wear testing ofelastic materials, rubbertires, conveyor belts, soles, soft synthetic leather, leather andother materials, w
Contact Now
SKZ129B DIN Abrasion Tester DIN AbraderStandardISO4649, DIN 53516Technical parameters:Sample load2.5N, 5N,10NStroke40m or 20mRoller speed40 ± 1r/minRoller diameterФ150 ± 0.2mmRoller length460mmSample dia.Ф16 ± 0.2mmPowerAC220V ± 10% 50HzDimension700mm × 340mm × 300mmWeight63kgEXCELLENT PERFORMANCE,SUPERB TECHNOLOGYStainless steel rollerAnti-corrosion and anti-rustThe operation interface is simple and clearStandard: lS04649, DIN 53516PRODUCT DISPLAYSKZ129B is suitable for wear testing ofelastic materials, rubbertires, conveyor belts, soles, soft synthetic leather, leather andother materials, wi
Contact Now
SKZ129A Akron Abrasion TesterApplied to test the wear ability of vulcanized rubber. It tests the abrasion consumption in certain testing range by the friction under certain tilt angle and load. With digital setting and displaying the times of friction, automatically stop and integrate the host and controller.Standard ISO:4661-1:1993, ISO 2481:1988, ISO 471:1983, ISO 1826:1981Technical parameters:Tire suffered force26.7N (2.7kgf)Tire axis rotary speed76±2r/minWheel axis speed33-35r/minAngle between the two axis0°~45°PowerAC220V±10%Dimension600×480×400 (mm)Weight60kg
Contact Now
SKZ129A Auto Akron Abrasion TesterStandardISO:4661-1:1993, ISO 2481:1988, ISO 471:1983, ISO 1826:1981Technical parameters:Tire suffered force26.7N (2.7kgf)Tire axis rotary speed76±2r/minWheel axis speed33-35r/minAngle between the two axis0°~45°PowerAC220V±10%Dimension600×480×400 (mm)Weight60kgProducts DescriptionSKZ129AAkron Abrasion TesterIS0:4661-1:1993I50 2481:1988IS0 471:1983I50 1826:1981The Angle between therubber wheel shaft and thegrinding wheel can beadjusted to 15°or 25°Stable base, strong structure.durable and now not handy to breakHigh exceptional
Contact Now
SKZ129A Auto Akron Abrasion TesterStandard ISO:4661-1:1993, ISO 2481:1988, ISO 471:1983, ISO 1826:1981Technical parameters:Tire suffered force26.7N (2.7kgf)Tire axis rotary speed76±2r/minWheel axis speed33-35r/minAngle between the two axis0°~45°PowerAC220V±10%Dimension600×480×400 (mm)Weight60kgProducts DescriptionSKZ129AAkron Abrasion TesterIS0:4661-1:1993I50 2481:1988IS0 471:1983I50 1826:1981The Angle between therubber wheel shaft and thegrinding wheel can beadjusted to 15°or 25°Stable base, solid structure.durable and not easy to breakHigh quality digital display,display the number of wearre
Contact Now
Product DescriptionLab Textile Taber Abrasion Tester SKZ167 Used for testing abrasion resistance of all fabrics, leathers, carpets, rubbers, plastic sheets, by taber method.Taber method: A rotating wear load is applied to the surface of the sample and theloss of weight, thickness, or other physical properties of the materiaas the number of wear increases is recorded.Standards: ISO5470-1, ASTM D3884, DIN53863.2Product ParametersItems Specification Working plate diameterФ115mmWorking plate speed of revolution75r/minGrinding wheel external dimensiondiameter Ф50mm, thickness 12mmCounting
Contact Now
SKZ136 Rubber Impact Resilience Tester DIN 53512 MeterTechnical parameters:Diameter of impactorФ15mmSpecimen specificationФ29mm×12.5mmImpact weight0.35-0.1kgImpact speed1.4+0.6m/sStrain energy density351+112kJ/m³Resilience value error±0.5%Dimension320mm×200mm×360mmWeight20kgSKZ136IMPACT RESILIENCE TESTEREXCELLENT PERFORMANCE,SUPERB TECHNOLOGYMOQ 1 pCFactory direct saleStandard:1S04662,ASTM-D 1054-66,DIN 535125KPRODUCT DISPLAYNDUSTERubber lmpact Resilience TesterThe instrument is the pendulumimpact resiliency tester to measure the resilience cost of vulcanized rubbelSuitable for
Contact Now
Lab Fabric Martindale Abrasion And Pilling Tester SKZ165A Used for testing the performance of the wearing resistance, abrasion, appearance change (pilling degree/class) of the textiles and membrane materials.Standards:ASTM D4970,ASTM D4966,ISO12947,JIS L1096,TM112 M&S, FZ/T20020,IWS TM196,ASTM D3886,DIN53863/53865, BS3424/5690,BS EN 388/530,ISO12945-2Test mode: Mode l: Circular specimen with the same material fabric at a given pressure, friction with the Lissajous graphic motion trajectory, can achieve the required speed, evaluating sample pilling.
Contact Now
M310F-A Multi-parameter AnalyzerPH1.1-5 points calibration with Standard Recognition.2.Selectable pH buffer groups, including NIST, DIN, GB, USA.3.Automatic electrode diagnosis with pH slope and offset display.
Contact Now
SKZ165 Martindale Pilling TesterUsed to evaluate how well textiles and membrane materials perform in terms of wearing resistance, abrasion, and appearance change (pilling degree/class).Standards:ASTM D4970,ASTM D4966,ISO12947,JIS L1096,TM112 M&S, FZ/T20020,IWS TM196,ASTM D3886,DIN53863/53865, BS3424/5690,BS EN 388/530,ISO12945-2Test mode:Mode 1: Using a circular specimen made of the same material fabric and friction with a Lissajous graphic motion trajectory, the specimen can reach the necessary speed while assessing sample pilling at a certain pressure.
Contact Now
ASTM-D 1054-66 Rubber Impact Resilience TesterTechnical parameters:Diameter of impactorФ15mmSpecimen specificationФ29mm×12.5mmImpact weight0.35-0.1kgImpact speed1.4+0.6m/sStrain energy density351+112kJ/m³Resilience value error±0.5%Dimension320mm×200mm×360mmWeight20kgSKZ136IMPACT RESILIENCE TESTEREXCELLENT PERFORMANCE,SUPERB TECHNOLOGYMOQ 1 pCFactory direct saleStandard:1S04662,ASTM-D 1054-66,DIN 535125KPRODUCT DISPLAYNDUSTERubber lmpact Resilience TesterThe instrument is the pendulumimpact resiliency tester to measure the resilience value of vulcanized rubbelSuitable for metallurgy, constructi
Contact Now
Lab PH Ion Tester I310TPRODUCT SPECIFICATIONSModelI310TParameterspH/ISE/Temp.(mV/pX)pHRange-2.00 to 20.00pHResolution0.1, 0.01 pHAccuracy±0.01 pHCalibration PointsUp to 5Standard CustomizationYesStandard RecognitionNIST, GB, USA and DIN buffersSlope LimitYesmV/ORPRange-2000.0 to 2000.0 mVResolution0.1 mVAccuracy±0.3 mV or ±0.1%pXRange-2.00 to 20.00 pXResolution0.1, 0.01 pXAccuracy±0.02 pXCalibration PointsUp to 5ISERange1.000e-9 to 9.999e+9Unitsmol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppbResolutionUp to 4 significant digitsAccuracy±0.5%Calibration PointsUp to 5TemperatureRange-5 to 110 ºC, 23 to 2
Contact Now
SKZ-SY3020/3060 Handheld SpectrophotometerSpecificationModelSKZ3020-Basic versionSKZ3060-Professional versionCaliberSingle Caliber 4mm or 8mmSwitchable caliber 4mm and 8mmSCI SCESCISCI and SCELight typeHigh accuracy full spectrum LEDHigh accuracy full spectrum LED+Dual UVFix positionVisualCamera locationRepeated Accuracy△E≤0.07△E≤0.03Color spaceCIE-Lab, CIE-LCh, Luv, Hunter-Lab, XYZ, Yxy, sRGB, DIN LAB99, CMYK (A/T/E/M/I) Field density, Munsell, Reflectance (bright vision), Blackness, YI yellow, Isochromatic spectrum (light jumping), hiding power, tint/strength/dye
Contact Now
SKZ136 Rubber Impact Resilience TesterRubber Impact Resilience Tester is the pendulum impact resiliency tester with energy 0.5J and applied to measure the resilience value of vulcanized rubber with hardness 30—85IRHD. It measures up to ISO4662, ASTM-D 1054-66,DIN 53512. Rubber Impact Resilience Tester is the pendulum impact resiliency tester to measure the resilience value of vulcanized rubber.
Contact Now
Digital Benchtop Ph Tester For Water PH300FPH300F Features:1. High resolution LCD display, 5.7 inches.2. Multi-reading feature allows auto-read, timed-read and continuous-read.3. Automatic/Manual temperature compensation ensures accurate results.4. Auto-hold feature senses and locks the measurement endpoint.5. Data Storage 500 sets (GLP-compliant).6. Support for USB or RS-232 communication.7. Reset feature automatically resumes all settings back to factory default options.8. 1-5 points calibration with Standard Recognition.9. Selectable pH buffer groups, including NIST, DIN, GB, USA.10.
Contact Now
Digital Paper Thickness Tester SKZ106AThe tester is applying to test the thickness of paper and cardboard. Standard:ISO534: Paper and board -Determination of thickness, density and specific volumeISO 438:1980. Paper -- Determination of bulking thickness and apparent densityGB/T451.3: paper and board-Determination of thicknessTechnical Parameters:Measure range0-6mmIndicator display range0-12.7mmAccuracy0.001mm or 0.01mm (paper board)Measuring area200mm²Pressure100 KpaValue error±2.5um or ±0.5%Dimension80×120×120 (mm)Weight5kg
Contact Now
This Laboratory Digester used in caustic cooking and acid cooking, It can also be used to cooking and oxygen bleaching for other liquid work pressure is not more than 8Kg / cm2 Structural Features:1.The device is mainly composed of a machine frame, steamer, reducer, heating laps,rolling bearing, no carbon brush and slip ring, and a safety valve, temperature control instrument, a pressure gauge, a needle valve.2.This device part uses the high quality stainless steel , with high corrosion resistance.3.The heating part of the electric heating ring is composed of six pieces, direct
Contact Now
High Quality Concora Medium Fluter (CCT, CMT) SKZ113To determinate of flat crush strength of corrugated paper when pressed standard waveform (i.e., from the flute corrugated base paper), comply with standard: ISO7263-1985: corrugating medium – Determination of flat crush resistance after laboratory fluting.Feature: 1.Using single-chip microprocessor control technology, Precision temperature controller
Contact Now
Product DescriptionHigh Quality Fiber Fineness AnalyzerFor the measurement of fiber diameter, cross-sectional analysis and textile content. Projection microscope method,Mode of operation: manual measurement (A type), automatic measurement (B type), multi-point measurement; automatic statistical analysis, report printing, photo printing.Standards: GB/T 10685, FZ/T30003, AATCC 20A, SN/T0756Features:1. fiber qualitative analysis: FZ / T 01057.3 《textile fiber identification method of the third part of the microscopy experiments.》 AATCC 20 《fiber qualitative analysis.》 2.
Contact Now
High Quality Box Compression Tester SKZ121Box Compression Tester is applicable in testing the compression endurance and stacking strength and press standard of corrugated carton. Test items:●Compressive test: to determine the maximum compression strength●Stacking test: to determine the stacking strength test,12 hours, 24 hours●Pressure standards test: testing whether the box reaches the preset compression or deformation of the requirements Standards:ISO2234, ISO2233, ISO2206, ISO12048. ISO2874, ISO2872.
Contact Now
M310T Water Quality AnalyzerGENERAL FEATURES4.3-inch color LCD touchscreen with high contrast.Auto, timed, and continuous reading are all possible with the multi-reading feature.Accurate findings are ensured by automatic or manual temperature correction.The measurement endpoint is sensed and locked by the auto-hold feature.Up to 500 sets of data can be stored for any parameter (GLP-compliant).USB communication support is provided.The battery service life is significantly increased by the auto-power-off feature.The "Reset" feature automatically returns all settings to their origi
Contact Now
Used to carry the heat-ageing test for plasticity material, insulation material. Temperature controlled by digital display, PID auto adjustment, can arbitrarily set the working temperature from room temperature to 200℃ or 300℃, automatically keep temperature.
Contact Now
SKZ1043 Automatic Potentiometric TitratorUsed for the detection of index with plausible ability analysis, can be used as extraordinary instrument for the detection of penicillin, by means of measuring the alternate in electrode potential, to measure the ion concentration, extensively used for the pharmaceutical industry, meals industry, petrochemical industry, metallurgy, environmental protection, electroplating substances industry.Main functions1.Titration type of chemical reaction: acid-base titration, redox titration
Contact Now