DIN Abrasion Meter-manufacture,factory,supplier from China

(Total 24 Products for DIN Abrasion Meter)
SKZ129B DIN Abrasion Tester DIN AbraderStandardISO4649, DIN 53516Technical parameters:Sample load2.5N, 5N,10NStroke40m or 20mRoller speed40 ± 1r/minRoller diameterФ150 ± 0.2mmRoller length460mmSample dia.Ф16 ± 0.2mmPowerAC220V ± 10% 50HzDimension700mm × 340mm × 300mmWeight63kgEXCELLENT PERFORMANCE,SUPERB TECHNOLOGYStainless steel rollerAnti-corrosion and anti-rustThe operation interface is simple and clearStandard: lS04649, DIN 53516PRODUCT DISPLAYSKZ129B is suitable for wear testing ofelastic materials, rubbertires, conveyor belts, soles, soft synthetic leather, leather andother materials, wi
Contact Now
SKZ129B DIN Abrasion TesterFor determination of abrasion resistance of rubber tires, rubber overshoes, adhesive tape, to identify the quality of rubber products. Rubber compounds were friction with the cloth in a certain load to determine the amount of abrasion of the sample within a predetermined stroke.Standard ISO4649, DIN 53516Technical parameters:Sample load2.5N, 5N,10NStroke40m or 20mRoller speed40 ± 1r/minRoller diameterФ150 ± 0.2mmRoller length460mmSample dia.Ф16 ± 0.2mmPowerAC220V ± 10% 50HzDimension700mm × 340mm × 300mmWeight63kg
Contact Now
SKZ129B DIN Abrasion Tester DIN AbraderStandard ISO4649, DIN 53516Technical parameters:Sample load2.5N, 5N,10NStroke40m or 20mRoller speed40 ± 1r/minRoller diameterФ150 ± 0.2mmRoller length460mmSample dia.Ф16 ± 0.2mmPowerAC220V ± 10% 50HzDimension700mm × 340mm × 300mmWeight63kgEXCELLENT PERFORMANCE,SUPERB TECHNOLOGYStainless steel rollerAnti-corrosion and anti-rustThe operation interface is simple and clearStandard: lS04649, DIN 53516PRODUCT DISPLAYSKZ129B is suitable for wear testing ofelastic materials, rubbertires, conveyor belts, soles, soft synthetic leather, leather andother materials, w
Contact Now
SKZ129A  Akron Abrasion TesterApplied to test the wear ability of vulcanized rubber. It tests the abrasion consumption in certain testing range by the friction under certain tilt angle and load. With digital setting and displaying the times of friction, automatically stop and integrate the host and controller.Standard ISO:4661-1:1993, ISO 2481:1988, ISO 471:1983, ISO 1826:1981Technical parameters:Tire suffered force26.7N (2.7kgf)Tire axis rotary speed76±2r/minWheel axis speed33-35r/minAngle between the two axis0°~45°PowerAC220V±10%Dimension600×480×400 (mm)Weight60kg
Contact Now
SKZ129A Auto Akron Abrasion TesterStandardISO:4661-1:1993, ISO 2481:1988, ISO 471:1983, ISO 1826:1981Technical parameters:Tire suffered force26.7N (2.7kgf)Tire axis rotary speed76±2r/minWheel axis speed33-35r/minAngle between the two axis0°~45°PowerAC220V±10%Dimension600×480×400 (mm)Weight60kgProducts DescriptionSKZ129AAkron Abrasion TesterIS0:4661-1:1993I50 2481:1988IS0 471:1983I50 1826:1981The Angle between therubber wheel shaft and thegrinding wheel can beadjusted to 15°or 25°Stable base, strong structure.durable and now not handy to breakHigh exceptional 
Contact Now
SKZ129A Auto Akron Abrasion TesterStandard ISO:4661-1:1993, ISO 2481:1988, ISO 471:1983, ISO 1826:1981Technical parameters:Tire suffered force26.7N (2.7kgf)Tire axis rotary speed76±2r/minWheel axis speed33-35r/minAngle between the two axis0°~45°PowerAC220V±10%Dimension600×480×400 (mm)Weight60kgProducts DescriptionSKZ129AAkron Abrasion TesterIS0:4661-1:1993I50 2481:1988IS0 471:1983I50 1826:1981The Angle between therubber wheel shaft and thegrinding wheel can beadjusted to 15°or 25°Stable base, solid structure.durable and not easy to breakHigh quality digital display,display the number of wearre
Contact Now
SKZ136  Rubber Impact Resilience Tester DIN 53512 MeterTechnical parameters:Diameter of impactorФ15mmSpecimen specificationФ29mm×12.5mmImpact weight0.35-0.1kgImpact speed1.4+0.6m/sStrain energy density351+112kJ/m³Resilience value error±0.5%Dimension320mm×200mm×360mmWeight20kgSKZ136IMPACT RESILIENCE TESTEREXCELLENT PERFORMANCE,SUPERB TECHNOLOGYMOQ 1 pCFactory direct saleStandard:1S04662,ASTM-D 1054-66,DIN 535125KPRODUCT DISPLAYNDUSTERubber lmpact Resilience TesterThe instrument is the pendulumimpact resiliency tester to measure the resilience cost of vulcanized rubbelSuitable for
Contact Now
Product DescriptionLab Textile Taber Abrasion Tester SKZ167 Used for testing abrasion resistance of all fabrics, leathers, carpets, rubbers, plastic sheets, by taber method.Taber method: A rotating wear load is applied to the surface of the sample and theloss of weight, thickness, or other physical properties of the materiaas the number of wear increases is recorded.Standards: ISO5470-1, ASTM D3884, DIN53863.2Product ParametersItems Specification Working plate diameterФ115mmWorking plate speed of revolution75r/minGrinding wheel external dimensiondiameter Ф50mm, thickness 12mmCounting
Contact Now
Lab Fabric Martindale Abrasion And Pilling Tester SKZ165A Used for testing the performance of the wearing resistance, abrasion, appearance change (pilling degree/class) of the textiles and membrane materials.Standards:ASTM D4970,ASTM D4966,ISO12947,JIS L1096,TM112 M&S, FZ/T20020,IWS TM196,ASTM D3886,DIN53863/53865, BS3424/5690,BS EN 388/530,ISO12945-2Test mode: Mode l: Circular specimen with the same material fabric at a given pressure, friction with the Lissajous graphic motion trajectory, can achieve the required speed, evaluating sample pilling.
Contact Now
M310F-A Multi-parameter AnalyzerPH1.1-5 points calibration with Standard Recognition.2.Selectable pH buffer groups, including NIST, DIN, GB, USA.3.Automatic electrode diagnosis with pH slope and offset display.
Contact Now
SKZ165 Martindale Pilling TesterUsed to evaluate how well textiles and membrane materials perform in terms of wearing resistance, abrasion, and appearance change (pilling degree/class).Standards:ASTM D4970,ASTM D4966,ISO12947,JIS L1096,TM112 M&S, FZ/T20020,IWS TM196,ASTM D3886,DIN53863/53865, BS3424/5690,BS EN 388/530,ISO12945-2Test mode:Mode 1: Using a circular specimen made of the same material fabric and friction with a Lissajous graphic motion trajectory, the specimen can reach the necessary speed while assessing sample pilling at a certain pressure.
Contact Now
PH510T Portable PH MeterPRODUCT SPECIFICATIONSModelPH510TParameterspH/Temp.(mV/ORP)pHRange-2.000 to 20.000 pHResolution 0.1, 0.01, 0.001pHAccuracy±0.002 pHCalibration PointsUp to 8Standard RecognitionUSA, NIST, MERK, JIS, GB and DIN buffersStandard CustomizationYesSlope LimitYesmV/ORPRange-2000 to 2000 mVResolution0.1, 0.01 mVAccuracy±0.1 mV or ±0.03%EH ORP ModeYesORP Calibration Points1 custom point (relative mV)TemperatureRange-10 to 135 ºC, 14 to 275 ºFUnitºC, ºFResolution0.1Accuracy0.1MeasurementReading ModeAuto Read (Fast, Medium, Slow), Timed, ContinuousTemp.
Contact Now
ASTM-D 1054-66 Rubber Impact Resilience TesterTechnical parameters:Diameter of impactorФ15mmSpecimen specificationФ29mm×12.5mmImpact weight0.35-0.1kgImpact speed1.4+0.6m/sStrain energy density351+112kJ/m³Resilience value error±0.5%Dimension320mm×200mm×360mmWeight20kgSKZ136IMPACT RESILIENCE TESTEREXCELLENT PERFORMANCE,SUPERB TECHNOLOGYMOQ 1 pCFactory direct saleStandard:1S04662,ASTM-D 1054-66,DIN 535125KPRODUCT DISPLAYNDUSTERubber lmpact Resilience TesterThe instrument is the pendulumimpact resiliency tester to measure the resilience value of vulcanized rubbelSuitable for metallurgy, constructi
Contact Now
SKZ-SY3020/3060 Handheld SpectrophotometerSpecificationModelSKZ3020-Basic versionSKZ3060-Professional versionCaliberSingle Caliber 4mm or 8mmSwitchable caliber 4mm and 8mmSCI SCESCISCI and SCELight typeHigh accuracy full spectrum LEDHigh accuracy full spectrum LED+Dual UVFix positionVisualCamera locationRepeated   Accuracy△E≤0.07△E≤0.03Color spaceCIE-Lab, CIE-LCh, Luv, Hunter-Lab, XYZ, Yxy, sRGB,   DIN LAB99, CMYK (A/T/E/M/I) Field density, Munsell, Reflectance (bright   vision), Blackness, YI yellow, Isochromatic spectrum (light jumping), hiding   power, tint/strength/dye
Contact Now
Lab PH Ion Tester I310TPRODUCT SPECIFICATIONSModelI310TParameterspH/ISE/Temp.(mV/pX)pHRange-2.00 to 20.00pHResolution0.1, 0.01 pHAccuracy±0.01 pHCalibration PointsUp to 5Standard CustomizationYesStandard RecognitionNIST, GB, USA and DIN buffersSlope LimitYesmV/ORPRange-2000.0 to 2000.0 mVResolution0.1 mVAccuracy±0.3 mV or ±0.1%pXRange-2.00 to 20.00 pXResolution0.1, 0.01 pXAccuracy±0.02 pXCalibration PointsUp to 5ISERange1.000e-9 to 9.999e+9Unitsmol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppbResolutionUp to 4 significant digitsAccuracy±0.5%Calibration PointsUp to 5TemperatureRange-5 to 110 ºC, 23 to 2
Contact Now
SKZ136 Rubber Impact Resilience TesterRubber Impact Resilience Tester is the pendulum impact resiliency tester with energy 0.5J and applied to measure the resilience value of vulcanized rubber with hardness 30—85IRHD. It measures up to ISO4662, ASTM-D 1054-66,DIN 53512. Rubber Impact Resilience Tester is the pendulum impact resiliency tester to measure the resilience value of vulcanized rubber.
Contact Now
Digital Benchtop Ph Tester For Water PH300FPH300F Features:1. High resolution LCD display, 5.7 inches.2. Multi-reading feature allows auto-read, timed-read and continuous-read.3. Automatic/Manual temperature compensation ensures accurate results.4. Auto-hold feature senses and locks the measurement endpoint.5. Data Storage 500 sets (GLP-compliant).6. Support for USB or RS-232 communication.7. Reset feature automatically resumes all settings back to factory default options.8. 1-5 points calibration with Standard Recognition.9. Selectable pH buffer groups, including NIST, DIN, GB, USA.10.
Contact Now
SKZ60G precision gloss meter projection Angle is 60 degrees, precision gloss meter measurement mode has automatic measurement, manual measurement, single measurement, average measurement, and can achieve cross-setting, providing a variety of combination of measurement modes.Functional characteristics1.Delicate, lightweight shape, carry, use are very convenient 2.Automatic calibration, no manual adjustment, high stability, that is, open measurement 3.Full intelligent design, single key operation, single hand can achieve all operations, easy to use 4.Long life light source, no nee
Contact Now
SKZ1040A-2 Microscopic Melting Point MeterMicroscopic Melting Point Meter, which uses a single-purpose microscope to observe the melting state of the sample to be tested, has an ultra-high cost performance, simple and stylish appearance, and simple and convenient operation; both the capillary method and the hot stage method can be used to measure the melting point of the sample, and the application field is more Extensive; it is the industry's first to adopt digital temperature control and closed-loop control to control the furnace temperature, which makes the furnace temperature control m
Contact Now
Product DescriptionDigital Multi Parameter Meter Ph Ec Tds Meter M510T Features:1. Color High contrast LCD touchscreen, 4.3 inches.2. Intelligent operation system provides features including user management, calibration management, electrode management, method management, data management, Log Management and etc.3. Multi-reading feature allows auto-read, timed-read and continuous-read.4. Automatic/Manual temperature compensation ensures accurate results.5. Auto-hold feature senses and locks the measurement endpoint.6. Data Storage 1000 sets for each parameter (GLP-compliant).7.
Contact Now
SKZ1013B/C High Precision Automatic Surface Tension Meter SolutionThe Automatic Floor Tensiometer is a sophisticated device that comprises an ultra-precise and reliable pressure measurement system, a microcomputer control system, and a platinum plate (ring) measurement device. It showcases a compact design, a user-friendly and dependable structure, and offers convenient operation in both automatic and manual modes.
Contact Now
Used to test the Vicat softening temperature and heat distortion temperature of polymer materials  Feature 1.Using meter to measure distortion and temperature controller to set temperature.2. Specimen stand can automatically go up and down and test 3 specimens in one time.
Contact Now
Electrical Conductivity Meter EC310T General Feature1. Colour high contrast LCD touch screen, 4.3 inches2. Multi-reading function allows automatic, timed and continuous readings3. Automatic/manual temperature compensation ensures accurate results 4. Auto hold function senses and locks the endpoint of the measurement.5. 500 data sets per parameter (GLP compliant)6. Supports USB communication7. Auto Power Off function extends battery life.8. Reset function automatically restores all settings to factory defaults9.
Contact Now
EC310F Laboratory Cond Meter Water EC Conductivity Meter GENERAL FEATURES1. LCD display screen, 3.5 inches.2. Multi-reading feature allows auto-read, timed-read and continuous-read.3. Automatic/Manual temperature compensation ensures accurate results.4. Auto-hold feature senses and locks the measurement endpoint.5. Data capacity of up to 500 sets for each parameter (GLP-compliant).6. Support for USB communication.7. Auto-power off feature effectively extends the battery service life.8. Reset feature automatically resumes all settings back to factory default options.9. IP65 waterproof.
Contact Now
Relate News
Laboratory pH meter (acidity meter) is an electrochemical analytical instrument used to measure the pH value of aqueous solutions. The pH meter adopts the potentiometric method, and the main measuring components are the reference electrode and glass electrode. The reference electrode is stable, while the glass electrode is sensitive.
This meter can test pH,mV, ORP, tesisitivity, TDS, salinity, dissolved oxygen and temperature in water solution, it is suitable used in lab for those units from industrial and mining enterprises,university and scientific research organ etc. There is a microprocessor chip inside the meter and the appearance of meter looks nice with easily operation.
SKZ111 paper carton moisture meter is a high-performance digital moisture measuring instrument introduced by our company in the domestic market with foreign advanced technology. The instrument adopts the principle of high frequency wave, the digital display, the sensor and the main body are integrated into one, and there are 6 gears used to measure the moisture of various paper, cardboard, tile paper, carton, pulp board, etc.
Our SKZ111B-1 grain moisture meter is a portable and easy-to-use device that can accurately measure the moisture content of 33 different types of grains including coffee beans. It supports English language and comes with CE and ISO9001 certifications, ensuring the quality and safety of the product.This grain moisture meter is designed with convenience in mind. It is light in weight, compact, and easy to carry around, making it ideal for on-site measurements.
Our company is specialized in manufacturing and supply Lab equipment: Scientific instrument, Analytical Instrument, Thermal Analysis, Moisture meter, Gas detector and testing instruments for pulps, paper, cardboards, plastic, rubber and textile. Our moisture meters and gas detectors obtained CE certification and professional test report in August 2021. We have original trademarks on July 19,2018 and intellectual property certificates on Decmeber 12,2018.
Lab hot air oven is an indispensable utility for your daily workflow, from simple glassware drying to very complex temperature-controlled heating applications.
SKZ111B-4 Microcomputer rice polisher can complete the whole process of rice husking and brown rice grinding through automatic one time, which can quickly and truly judge the quality of rice. SKZ111B-4 Microcomputer rice polisher has the advantages of simple operation, good white effect, short working time, strong and wear-resistant head, beautiful appearance and so on.
Dumplings are full, life is warm, dumplings are sweet and tender. Happy Dragon Boat Festival to my dearest relatives!
SKZ108A/B Mullen Bursting Tester is a basic instrument for testing the strength of paper and paperboard.
SKZ401 Rubber Vulcanizer is mainly used for vulcanizing flat type tape (such as conveyor belt, transmission belt, referred to as flat belt), belongs to hydraulic machinery, the main function of plate vulcanizing machine is to provide the pressure and temperature required for vulcanization. The pressure is generated by the hydraulic system through the hydraulic cylinder, and the temperature is provided by the heating medium (usually steam, thermal oil, etc., and superhot water is also useful).
x

Submitted successfully

We will contact you as soon as possible

Close