DSC Differential Scanning Calorimeter SKZ1052Product descriptionDSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control.
Contact Now
SKZ1052 Differential Scanning CalorimeterDSC is intended to decide the internal intensity progress connecting with temperature and intensity stream, it is broadly utilized in the field of polymer improvement, execution testing and quality control.
Contact Now
SKZ1052 Differential Scanning Calorimeter (DSC)Performance testing, pleasant control, and polymer lookup all make full-size use of DSC.The purpose is to decide how temperature and warmth glide relate to the internal warmth transition.DSC lookup and improvement encompasses the domains of glass transition temperature,melting point, segment transition, bloodless crystallization, and oxidation induction time (OIT).Features:1.
Contact Now
SKZ-1052 DSC Test Differential Scanning Calorimeter For LabDSC is designed to decide the internal warmth transition touching on to temperature and heat flow, it is extensively used in the area of polymer development, overall performance trying out & first-rate control.
Contact Now
SKZ1052 differential scanning calorimetry dsc analysisPerformance testing, quality control, and polymer research all make extensive use of DSC.The goal is to determine how temperature and heat flow relate to the inner heat transition.DSC research and development encompasses the domains of glass transition temperature,melting point, phase transition, cold crystallization, and ox
Contact Now
SKZ1052 Automatic Pressure Differential Scanning Calorimeter Deutsch For SaleMain Features:1. The industrial-grade 7-inch contact display screen shows prosperous information.2. Brand-new steel furnace physique structure, with higher baseline and greater accuracy. The heating adopts oblique conduction method, which has excessive uniformity andstability, reduces pulse radiation, and is higher than standard heating mode.3.
Contact Now
SKZ1052 Dsc Differential scanning calorimetry InstrumentsMain Features:1. The industrial-grade 7-inch contact show display screen suggests affluent information.2. Brand-new metal furnace physique structure, with greater baseline and increased accuracy. The heating adopts indirect conduction method, which has immoderate uniformity andstability, reduces pulse radiation, and is greater than general heating mode.3. USB dialog interface, sturdy versatility, reliable and uninterrupted communication, helps self-recovery connection function.4.
Contact Now
SKZ1052C-1L Differential Scanning Calorimeter360° lab and factory: https://skztester.en.alibaba.com/company_profile.html?spm=a2700.shop_oth.8.9DSC Video: https://youtu.be/m9z9fUnwLvg DSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control.
Contact Now
DSC is widely utilized in the fields of polymer research, performance testing, and quality control. It is intended to identify the inner heat transition in relation to temperature and heat flow. The fields of glass transition temperature, melting point, cold crystallization, phase transition, and oxidation induction time (OIT) are all included in DSC study and development.Standards:ISO/TR10837:1991, ASTM D3895-1998, ASTM E 967, ASTM E 968, ASTM E 793, ASTM D 3895, ASTM D 3417, ASTM D 3418, ISO 11357-6Features: 1. Rich information is shown on an industrial-grade 7-inch touch screen.2.
Contact Now
SKZ XRY-1A Automatic Oxygen Bomb Calorimeter For Coal AnalysisIt is suitable to determine calorific value of combustible materials such as petroleum products without water (gasoline, jet fuels, diesel oil and fuel oils, etc.), coal, coke and paraffin, etc.Main technical specifications1. Heat capacity: 14400 J/K~15000 J/K2. Resolution: 0.001 K3. Measurement accuracy: ± 60J/g4. Repeatability: ≤0.2% (Grade C)5. Pressure endurance of oxygen bomb: 20 MPa6. Temperature measurement range: 10 ℃~35 ℃7.
Contact Now
SKZ1055 Differential Thermal AnalyzerDifferential thermal analysis: temperature under program control, the relationship and difference of temperature between the measured material and the reference.The DTA curves is to describe the changing relationship depending on temperature and time between the measured material and the reference compound. During the test, the sample temperature changes due to the phase change or an endothermic or exothermic reaction effects.
Contact Now
SKZ1064 Oxygen Bomb CalorimeterOxygen bomb calorimeter can be used to measure the calorific value of solid or liquid samples, measuring samples in a closed container (oxygen bomb), oxygen-filled environment, the heat generated by combustion, the measurement results called the combustion value, calorific value , BTU and so on. Calorific value results have the value of determining other values to determine the quality of the sample as a basis for calculating the price (eg, coal), as well as physiology (eg, energy distribution in ecology, energy metabolism in animal nutrition studies, etc.),
Contact Now
Digital Oxygen Bomb Calorimeter SKZ1064Oxygen bomb calorimeter can be used to measure the calorific value of solid or liquid samples, measuring samples in a closed container (oxygen bomb), oxygen-filled environment, the heat generated by combustion, the measurement results called the combustion value, calorific value , BTU and so on.Calorific value results have the value of determining other values to determine the quality of the sample as a basis for calculating the price (eg, coal), as well as physiology (eg, energy distribution in ecology, energy metabolism in animal nutrition studies, etc.
Contact Now
SKZ XRY-1A+ Oxygen Bomb Calorimeter Description In ChemistryI. SummaryThe instrument is designed and made as per the National Standard of People’s Republic of China GB/T213-2008 and ASTM D240 Test Method for Calorific Value of coal, GB/T384-1988 Test Method for Calorific Value of Petroleum Products and Calibration Regulation of People’s Republic of China JJG672-2001 Oxygen Bomb CalorimeterII. Main technical specifications1. Power supply: AC 220V±5%, 50 Hz2. Total power consumption: ≤150W.3. Heat capacity: (14000~15000) J/K4. Resolution: 0.001 K5.
Contact Now
XRY-1A+ Oxygen Bomb Calorimeter Price For Sale It is appropriate to decide calorific price of flamable substances such as petroleum merchandise except water (gasoline, jet fuels, diesel oil and gas oils, etc.), coal, coke and paraffin, etc.Main technical features1. This instrument adopts sealed oxygen bomb. The total shape adopts stainless metal material. The power is adequate to face up to the max stress (60~70 atmospheric pressure) when the stable burning. And it can withstand the better stress when liquid gas burning.2.
Contact Now
DTA Differential Thermal Analyzer SKZ1055Differential thermal analysis: temperature under program control, the relationship and difference of temperature between the measured material and the reference.The DTA curves is to describe the changing relationship depending on temperature and time between the measured material and the reference compound. During the test, the sample temperature changes due to the phase change or an endothermic or exothermic reaction effects.
Contact Now
STA Synchronous Thermal Analyzer SKZ1060ASimultaneous thermal analysis (DSC/DTA, TGA) is a combination of differential heating and thermo gravimetric . It can not only study the change of sample quality with temperature or time in the process of heating and constant temperature, but also study and analyze the change process of the sample, by the heat generated changes.
Contact Now
SKZ1060 Lab Synchronous Thermal AnalyzerSimultaneous thermal Analyzer STA is a mixture of differential heating and thermo gravimetric .
Contact Now
SKZ111A-2 Cotton Moisture MeterSuitable for cotton, polyester, linen, velvet, wool, acrylic, and polypropylene fiber.HIGH FREQUENCY PRINCILENON-DESTRUCTIVE TESTINGLCD DIGITAL DISPLAY.MEASURING RANGE: 0~40%RESOLUTION: 0.1%SCANNING DEPTH: 50MMSMALL SIZEEASY TO CARRY.SUITABLE FOR FIELD USEPACKING AND TRANSPORTATIONevery details will be checked to assure the productUPS,FedEx Express,TNT,EMS,aramex,DHL WORLDWIDE EXPRESSCompany ProfileThe innovative technology-based SKZ Moisture Meter is a highly precise moisture measuring tool that finds extensive application across multiple sectors.
Contact Now
MiniMeta Portable Small Size Gas Detector Hydrogen fluoride Sensor HF Gas TesterMiniMeta is a maintenance free single gas detector that is the most reliable, user-friendly, and cost-effective detection solution to ensure worker safety and operational compliance.
Contact Now
Coating Test machineLaboratory small coating test machine, By controlling the speed and pressure to ensure a stable coating effect, to ensure uniformity and coating stability. It can works for coating test of paper, plastic, metal, PVC, PET, fabric, aluminum plate, etc.
Contact Now
Dart impact testing machine used for plastic films and sheets of impact test to evaluate the impact resistance, it adopts background light source for test results.StandardISO7765-85: Determination for Impact Resistance of Plastic Film and SheetingGB9639-88: Impact Resistance Test of Plastic Films and SheetsASTM D1709 - 09 Standard Test Methods for Impact Resistance of Plastic Film by the Free-Falling Dart MethodTechnical parametersDart-head weight50-2000g, 5g/incremental (5g*5pcs,15g*15pcs, 30g*10pcs, 45g*10pcs, 80g*10pcs, 90g*15pcs)Dart-head semi-diameterA method: R19
Contact Now
SKZ1050C NH3 H2S 2 In 1 Ammonia Hydrogen Sulfide Portable Sensor Multi Gas DetectorOperation1. A single key that can be removed from misuse situations to restore the system to its initial configuration.2. There are two configurable sound and light alarm locations.3. A large-capacity lithium polymer rechargeable battery.4.
Contact Now
TU1000P Portable TurbidimeterGENERAL FEATURE850nm LED light Source.Uses Nephelometric principle with 90° detection.Meets ISO 7027 and offers consistent light source for higher accuracy.Selectable turbidity units, including the NTU, FNU and EBC.Settable parameters, including user ID, number of calibration points, data and time, etc.Auto-power-off feature effectively extends the battery usage time.IP65 waterproof.
Contact Now