SKZ XRY-1A Automatic Oxygen Bomb Calorimeter For Coal AnalysisIt is suitable to determine calorific value of combustible materials such as petroleum products without water (gasoline, jet fuels, diesel oil and fuel oils, etc.), coal, coke and paraffin, etc.Main technical specifications1. Heat capacity: 14400 J/K~15000 J/K2. Resolution: 0.001 K3. Measurement accuracy: ± 60J/g4. Repeatability: ≤0.2% (Grade C)5. Pressure endurance of oxygen bomb: 20 MPa6. Temperature measurement range: 10 ℃~35 ℃7.
Contact Now
SKZ1064 Oxygen Bomb CalorimeterOxygen bomb calorimeter can be used to measure the calorific value of solid or liquid samples, measuring samples in a closed container (oxygen bomb), oxygen-filled environment, the heat generated by combustion, the measurement results called the combustion value, calorific value , BTU and so on. Calorific value results have the value of determining other values to determine the quality of the sample as a basis for calculating the price (eg, coal), as well as physiology (eg, energy distribution in ecology, energy metabolism in animal nutrition studies, etc.),
Contact Now
XRY-1A+ Oxygen Bomb Calorimeter Price For Sale It is appropriate to decide calorific price of flamable substances such as petroleum merchandise except water (gasoline, jet fuels, diesel oil and gas oils, etc.), coal, coke and paraffin, etc.Main technical features1. This instrument adopts sealed oxygen bomb. The total shape adopts stainless metal material. The power is adequate to face up to the max stress (60~70 atmospheric pressure) when the stable burning. And it can withstand the better stress when liquid gas burning.2.
Contact Now
SKZ XRY-1A+ Oxygen Bomb Calorimeter Description In ChemistryI. SummaryThe instrument is designed and made as per the National Standard of People’s Republic of China GB/T213-2008 and ASTM D240 Test Method for Calorific Value of coal, GB/T384-1988 Test Method for Calorific Value of Petroleum Products and Calibration Regulation of People’s Republic of China JJG672-2001 Oxygen Bomb CalorimeterII. Main technical specifications1. Power supply: AC 220V±5%, 50 Hz2. Total power consumption: ≤150W.3. Heat capacity: (14000~15000) J/K4. Resolution: 0.001 K5.
Contact Now
Digital Oxygen Bomb Calorimeter SKZ1064Oxygen bomb calorimeter can be used to measure the calorific value of solid or liquid samples, measuring samples in a closed container (oxygen bomb), oxygen-filled environment, the heat generated by combustion, the measurement results called the combustion value, calorific value , BTU and so on.Calorific value results have the value of determining other values to determine the quality of the sample as a basis for calculating the price (eg, coal), as well as physiology (eg, energy distribution in ecology, energy metabolism in animal nutrition studies, etc.
Contact Now
SKZ1052 Differential Scanning Calorimeter (DSC)Performance testing, pleasant control, and polymer lookup all make full-size use of DSC.The purpose is to decide how temperature and warmth glide relate to the internal warmth transition.DSC lookup and improvement encompasses the domains of glass transition temperature,melting point, segment transition, bloodless crystallization, and oxidation induction time (OIT).Features:1.
Contact Now
SKZ-1052 DSC Test Differential Scanning Calorimeter For LabDSC is designed to decide the internal warmth transition touching on to temperature and heat flow, it is extensively used in the area of polymer development, overall performance trying out & first-rate control.
Contact Now
SKZ1052 Automatic Pressure Differential Scanning Calorimeter Deutsch For SaleMain Features:1. The industrial-grade 7-inch contact display screen shows prosperous information.2. Brand-new steel furnace physique structure, with higher baseline and greater accuracy. The heating adopts oblique conduction method, which has excessive uniformity andstability, reduces pulse radiation, and is higher than standard heating mode.3.
Contact Now
DSC Differential Scanning Calorimeter SKZ1052Product descriptionDSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control.
Contact Now
SKZ401 Vulcanizing Machine For SaleRubber vulcanizer is mostly used for thermosetting polymers, pressed rubber products, and insulation. This test apparatus contains an automatic temperature, pressure, and time control unitClamping, a regular work cycle, and automatic pressure compensation are all achievableFeatures1. comprises of the host, hydraulic systems, and electrical control system as its three main components2. It has time, pressure, and temperature control devices as well as clamping and work cycle timing capabilities.
Contact Now
SKZ1052 Differential Scanning CalorimeterDSC is intended to decide the internal intensity progress connecting with temperature and intensity stream, it is broadly utilized in the field of polymer improvement, execution testing and quality control.
Contact Now
SKZ1052 Dsc Differential scanning calorimetry InstrumentsMain Features:1. The industrial-grade 7-inch contact show display screen suggests affluent information.2. Brand-new metal furnace physique structure, with greater baseline and increased accuracy. The heating adopts indirect conduction method, which has immoderate uniformity andstability, reduces pulse radiation, and is greater than general heating mode.3. USB dialog interface, sturdy versatility, reliable and uninterrupted communication, helps self-recovery connection function.4.
Contact Now
The sample cutter for Cobb absorbency testing.Technical parameters:Specimen thickness0.1-1.0(mm)Error±0.2mmSpecimen diameter125mmDimension 240×288×435(mm)Weight28Kg
Contact Now
Tumble Dryer For Textile Shrinkage Tester SKZ162-1Used for the drying of fabrics, clothing and other textiles after shrinkage test.Standard: ISO06330 Technical parametersRated dry sample capacity10kgDrying temperatureroom temperature -80 ℃Drum diameter695mmDrum depth435mmRoller volume165LRoller speed50 r /minLifting pieces No. 3 (120 degrees apart)PowerAC220v • 50Hz 5.5 KWDimensions 785 × 960 × 1365mmWeight100Kg
Contact Now
Digital Density Balance for Emulsions Chemical Solution SKZ300EApplicationsDirect readings, with temperature compensation, and Solution compensation, more humanized operation, suitable for onsite operations.For density determination of Chemical solution, additives, suspensions, emulsions, dispersions, homogeneous type solution, mouthwash, pharmaceutical, and other high viscosity, suspensions, emulsions, colloidal liquid Features1.Direct reading density of liquid, which density> 1 or <12.
Contact Now
The rubber fatigue (Flex) cracking machine is used to test the cracking performance of vulcanized rubber and rubber shoes by repeated flex.Standard: ISO132, ISO133.Feature 1.Host and controller with digital setting, LED display flex times and automatic stands. 2.Separately fix the specimen in the clamp. It is the newest improved testing machine.Technical parameters:Frequency of down clamp300r/minAdjustable max distance between upper and down clamp200mmAdjustable max distance of eccentric wheel50mmMax trip of down clamp100mmDimension1000*500*1200 (mm)Net weight200kg
Contact Now
Product DescriptionLaboratory Air Permeability Tester For TextileFor measuring the air permeability of a variety of textile fabrics, including industrial fabrics, nonwovens and other textile products and other breathable materials.Standards:GB/T 5453、GB/T 13764、ISO 9237、ASTM D737Feature:1. Automatic clamping, automatic nozzle replacement, quick test.2. Microcomputer processing, test results directly, without manual calculation.3. Chinese and English touch screen menu operation, configured with computer interface.4.
Contact Now
Product UsageThe SKZ1050-CLO2 gas detector is a device specifically designed for monitoring the concentration of chlorine dioxide, suitable for water pretreatment processes and sewage treatment plants. This detector can effectively control the concentration of chlorine dioxide, ensuring that the water quality meets relevant disinfection requirements and standards.
Contact Now
SKZ1052C-1L Differential Scanning Calorimeter360° lab and factory: https://skztester.en.alibaba.com/company_profile.html?spm=a2700.shop_oth.8.9DSC Video: https://youtu.be/m9z9fUnwLvg DSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control.
Contact Now
Digital Ph Meter For Water PH200EGENERAL FEATURESHigh resolution LCD display screen, 6.0 inches.Multi-reading feature allows auto-read and continuous-read.Automatic/Manual temperature compensation ensures accurate results.Auto-hold feature senses and locks the measurement endpoint.Data Storage 50 sets for each parameter.Reset feature automatically resumes all settings back to factory default options.IP54 waterproof.1-3 points calibration with Standard Recognition.Automatic/Manual temperature compensation ensures accurate resultsIncludesE-301-QC 3 in 1 pH composite electrodeNIST pH standard sol
Contact Now
Air Permeability Tester For Paper SKZ119 The tester is designed to assess the moderate air permeability of paper within the range of 0 to 17μm (Pa.S), in accordance with the ISO 5636-2:1984 standardfor determining air permeance using the Schopper method.SpecificationTesting range0-17μm/(Pa.S)Pressure area10.0±0.05cm²Pressure error1.00±0.01kPaSample size60×100 (mm)Dimension350×250×1160 (mm)Weight21.5kgConstant pressure difference is 1Kpa Airflow (ml/s) Test lasting time (S) Measured volume (ml) 0.13—0.33 &nb
Contact Now
SKZ111C Food Moisture MeterCharacteristic:1.With a frequency of over 10 MHZ, the high-frequency principle is used in the 316L steel + PTFE sensor probe, which resists corrosion and wear2.10 measurement switch stalls are present3.Large measurement range, excellent accuracy, compact size, low weight, and speedy determinationDisplayLCD displayMeasuring range0 ~ 80%Resolution0.1%Accuracy0%-10%: ±0.2%10%-40%: ±0.5%40%-80%:±1%Probe200mmPower9V battery*1Dimesion160mm × 60mm × 27mmNet weight/gross weight250g/500gPackage size260X 220 X 100 mm
Contact Now
Digital Density Balance For Gold K Value SKZ400To test density of solid, liquid, powder, water-absorbent sample and Gold K value (A) Feature: 1. High-precision sensor, impact resistance, anti-overload, to ensure weighing accuracy and stability.2. Built-in rigorous test and calculation procedures, direct display density, without manual conversion.3. Aluminum shell, to enhance the anti-static balance anti-interference ability.4. High contrast LCD liquid crystal display, clear and intuitive readings.5.
Contact Now
Digital Density Balance For Solid Rubber Grain SKZ300A Direct readings, with temperature compensation, and Solution compensation, more humanized operation, suitable for onsite operations.For density determination of rubber, plastic, wire and cable, electrical appliances, sports equipment, tires, glass products, hard alloy, powder metallurgy, magnetic materials, seals, ceramics, sponge, EVA materials, foam materials, alloys, friction materials, New materials, battery materials.Features1. Direct reading density and volume of solid, particles
Contact Now