SKZ1053 Automatic Thermo GravimetricAnalysis Tga PriceThermo gravimetric evaluation (TG, TGA) is to examine the exchange of pattern exceptional with temperature or time in the technique of heating and regular temperature, the reason is to learn about the thermal balance and composition of the material.Widely used in the lookup and development, procedure optimization and excellent manage of plastics, rubber, coatings, pharmaceuticals, catalysts, inorganic materials, steel substances and composite substancesController and software program advantages:1.
Contact Now
TGA Thermo Gravimetric Analyzer SKZ1053Product descriptionThermo gravimetric analysis (TG, TGA) is to observe the change of sample quality with temperature or time in the process of heating and constant temperature, the purpose is to study the thermal stability and composition of the material. Widely used in the research and development, process optimization and quality control of plastics, rubber, coatings, pharmaceuticals, catalysts, inorganic materials, metal materials and composite materials. Technical parametersTemperature rangeActual maximum temperature 1150℃(S
Contact Now
I300F Benchtop Ion MeterSupport for USB or RS-232 communication. Reset feature automatically resumes all settings back to factory default options. IP54 waterproof.PRODUCT SPECIFICATIONSModelI300FParameterspH/ISE/Temp.(mV/pX)pHRange-2.00 to 20.00 pHResolution0.1, 0.01 pHAccuracy±0.01 pHmVRange-2000.0 to 2000.0 mVResolution0.1, 0.01 mVAccuracy±0.1 mV or ±0.03% of reading whichever is greaterpXRange-2.00 to 20.00 pXResolution0.1, 0.01 pXAccuracy±0.01 pXCalibration PointsUp to 5ISERange1.000e-9 to 9.999e+9Unitmol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppbResolutionUp to 4 significant digitsAcc
Contact Now
SKZ1060 Lab Synchronous Thermal AnalyzerSimultaneous thermal Analyzer STA is a mixture of differential heating and thermo gravimetric .
Contact Now
SKZ1053 Thermal Gravimetric AnalyzerWhen heating a material to look into its composition and thermal stability, thermogravimetric analysis (TG, TGA) is used to monitor changes in sample quality over time or at various temperatures.widely utilized in the development, manufacturing, quality assurance, and process optimization of polymers, rubber, coatings, medicines, catalysts, inorganic, metal, and composite materials.Uses: oxidation and reduction, breakdown process, moisture and volatiles, reaction kinetics, additions and fillers, adsorption and desorption, and quantitative component anal
Contact Now
SKZ1013 Automatic TensiometerThe automatic surface tensiometer consists of a highly precise and stable force measurement system, a microcomputer control system, and a platinum plate (ring) measurement device. It is designed to be compact, with a simple and reliable structure, and easy to operate either in automatic or manual mode. This device offers various features such as net weight measurement throughout the entire range with a one-key minimum clearing function, automatic calibration for the entire range, excellent repeatability, and accurate and reliable test results.
Contact Now
STA Synchronous Thermal Analyzer SKZ1060ASimultaneous thermal analysis (DSC/DTA, TGA) is a combination of differential heating and thermo gravimetric . It can not only study the change of sample quality with temperature or time in the process of heating and constant temperature, but also study and analyze the change process of the sample, by the heat generated changes.
Contact Now
PH200EM Benchtop Ph MeterPRODUCT SPECIFICATIONSModelPH200EMParameterspH/mVpHRange-2.000 to 18.000 pHResolution 0.01pHAccuracy±0.01 pHCalibration PointsUp to 3Standard RecognitionNF buffersmV/ORPRange-1999 to 1999 mVResolution1 mVAccuracy±0.1%FSMeasurementReading ModeAuto Read , ContinuousTemp.
Contact Now
SKZ1043B Automatic Potentiometric TitratorApplication: Widely used in food additives, food safety, pharmaceutical production, petrochemical, quality control, research institutionsTypical titration applications: Features: 1. The compact designed integrated titrator and convenient automatic titration system a). Burette valve integrated design, easy to replace, avoid different titration, mutual interference of different solutions b).
Contact Now
SKZ-SY3020 Spectrophotometers 1. 400-700nm, full-band balanced LED ligh source 2. High precision: 0.01, accurate measurement 3. Manual input LAB value 4. Measuring aperture: 4mm or 8mm optional 5. Accurate results, one second measurement 6. All kinds of specimens can be tested 7. Multiple measurement modes available 8.
Contact Now
Lab PH Ion Tester I310TPRODUCT SPECIFICATIONSModelI310TParameterspH/ISE/Temp.(mV/pX)pHRange-2.00 to 20.00pHResolution0.1, 0.01 pHAccuracy±0.01 pHCalibration PointsUp to 5Standard CustomizationYesStandard RecognitionNIST, GB, USA and DIN buffersSlope LimitYesmV/ORPRange-2000.0 to 2000.0 mVResolution0.1 mVAccuracy±0.3 mV or ±0.1%pXRange-2.00 to 20.00 pXResolution0.1, 0.01 pXAccuracy±0.02 pXCalibration PointsUp to 5ISERange1.000e-9 to 9.999e+9Unitsmol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppbResolutionUp to 4 significant digitsAccuracy±0.5%Calibration PointsUp to 5TemperatureRange-5 to 110 ºC, 23 to 2
Contact Now
SKZ1062B Dry method laser particle size AnalyzerSpecifications1, measuring range: 0.1 to 800 microns 2. Accuracy: <± 1% (national standard D50) 3. Repeatability: <± 1% (national standard D50) 4, Power: AC 220 ± 10V, 50Hz, 200W 5. Dimensions: Host: 1000 × 330 × 300mm, dry injection system: 350 × 330 × 300mm 6, Weight: 40KG Dispersion method System includes a laser particle size analyzer, automatic dry dispersion system, composed of Silent oil free air compressor, high efficiency condenser section.
Contact Now
SKZ1050E O2 Analyzer★ A 3.5-inch color screen with outstanding definition. The outside is composed of material resistant to wear in aircraft 2.
Contact Now
Automatic Potentiometric Titration Titrator Ti-50GENERAL FEATURES1. 7” colorful touchscreen and smart guide system.2. Titration methods, curves and results are displayed in detail.3. 1 extra burette driver can be installed (optional).4. Replaceable burette with high-accuracy (10 ml or 20 ml selectable).5. Intelligent operation system provides features including user management, method management, electrode management, titrant management, data management, etc.6. Support the following titration modes: DET (dynamic equivalence point titration), MET (monotone equ
Contact Now
Digital Automatic Polarimeter SKZ1039BPolarimeter is the testing instruments to measure the optical rotation of material. By measurement of optical rotation of the sample can be analyzed to determine the concentration of substance, the content and purity. Widely used in pharmaceutical, drug testing, sugar, food, spices, MSG and chemical and oil industry. Features:1. Using life of more than 5000h diode as a light source, instead of the previous sodium lamp and Halogen, which life is short, easy to damage and high temperature.2.
Contact Now
Laser Particle Size Analyzer SKZ1062A Technical characteristic:Standard: ISO133201. The measurement ranges are 0.02~1200 μm (SKZ1062A-1) and 0.1~800 μm (SKZ1062A).2. Tolerance for accuracy: ± 1% (DS50 national standard)3. Repeatability deviation: ± 1% (based on national norm D50)4.
Contact Now
M310F-A Multi-parameter AnalyzerPH1.1-5 points calibration with Standard Recognition.2.Selectable pH buffer groups, including NIST, DIN, GB, USA.3.Automatic electrode diagnosis with pH slope and offset display.
Contact Now
Automatic Surface Tension Meter SKZ1013Automatic surface tensiometer, made up of high precise and stable force measurement system, microcomputer control system, platinum plate (ring) measurement device, is compact in design, simple and reliable in structure, easy in operation (automatic/manual). It features net weight in whole range (one-key minimum clearing), whole range automatic calibration, good repeatability, accurate and reliable test result as well as liquid crystal display of test data with RS232C output interface. Features: 1.
Contact Now
SKZ1052 Automatic Pressure Differential Scanning Calorimeter Deutsch For SaleMain Features:1. The industrial-grade 7-inch contact display screen shows prosperous information.2. Brand-new steel furnace physique structure, with higher baseline and greater accuracy. The heating adopts oblique conduction method, which has excessive uniformity andstability, reduces pulse radiation, and is higher than standard heating mode.3.
Contact Now
M310T Water Quality AnalyzerGENERAL FEATURES4.3-inch color LCD touchscreen with high contrast.Auto, timed, and continuous reading are all possible with the multi-reading feature.Accurate findings are ensured by automatic or manual temperature correction.The measurement endpoint is sensed and locked by the auto-hold feature.Up to 500 sets of data can be stored for any parameter (GLP-compliant).USB communication support is provided.The battery service life is significantly increased by the auto-power-off feature.The "Reset" feature automatically returns all settings to their origi
Contact Now
SKZ1062F Nano Particle Size Analyzer FeatureHigh-speed photon correlator and professional high-performance photomultiplier tube as the core device for fast, high resolution, repeatability and accuracy1. Advanced test principle: Using dynamic light scattering principle and photon correlation spectroscopy technology, the particle size is determined according to the speed of Brownian motion of the particles in the liquid. The small particle Brownian motion speed is fast, and the large particle Brownian motion speed is slow.
Contact Now
SKZ1018C Fully Automatic Volumetric Karl Fischer TitrationAdopted Karl Fischer volumetric moisture can be measured liquids, solids and gases in the sample crystal water, adsorbed water, free water. StandardsISO 10337,ASTM D 1744, ISO 760 , ASTM E203Feature1. Huge variety LCD show, English menu activity.2. Full powerful showcase, WINDOWS working style simple to utilize.3. Shown at the same time (dampness content, rate, PPM content, reagent utilization), variety titration bend dynamic showcase4.
Contact Now
Ti-50 Automatic Potential TitratorSupport titration modes: DET (dynamic equivalence point titration), MET (monotone equivalence point titration), SET (Preset Endpoint Titration) and MAT (manual titration). pH calibration and measurement are supported. Up to 100 user-defined methods and 10 user-defined shortcuts. Auto calculation with pre-defined formula. Store up to 200 titration data sets (GLP-compliant). Data analysis feature helps user review, compare and recalculate results. Data can be easily transferred to printer via RS-232 communi
Contact Now
Product DescriptionHigh Quality Fiber Fineness AnalyzerFor the measurement of fiber diameter, cross-sectional analysis and textile content. Projection microscope method,Mode of operation: manual measurement (A type), automatic measurement (B type), multi-point measurement; automatic statistical analysis, report printing, photo printing.Standards: GB/T 10685, FZ/T30003, AATCC 20A, SN/T0756Features:1. fiber qualitative analysis: FZ / T 01057.3 《textile fiber identification method of the third part of the microscopy experiments.》 AATCC 20 《fiber qualitative analysis.》 2.
Contact Now