ASTM-D 1054-66 Rubber Impact Resilience TesterTechnical parameters:Diameter of impactorФ15mmSpecimen specificationФ29mm×12.5mmImpact weight0.35-0.1kgImpact speed1.4+0.6m/sStrain energy density351+112kJ/m³Resilience value error±0.5%Dimension320mm×200mm×360mmWeight20kgSKZ136IMPACT RESILIENCE TESTEREXCELLENT PERFORMANCE,SUPERB TECHNOLOGYMOQ 1 pCFactory direct saleStandard:1S04662,ASTM-D 1054-66,DIN 535125KPRODUCT DISPLAYNDUSTERubber lmpact Resilience TesterThe instrument is the pendulumimpact resiliency tester to measure the resilience value of vulcanized rubbelSuitable for metallurgy, constructi
Contact Now
DSC is widely utilized in the fields of polymer research, performance testing, and quality control. It is intended to identify the inner heat transition in relation to temperature and heat flow. The fields of glass transition temperature, melting point, cold crystallization, phase transition, and oxidation induction time (OIT) are all included in DSC study and development.Standards:ISO/TR10837:1991, ASTM D3895-1998, ASTM E 967, ASTM E 968, ASTM E 793, ASTM D 3895, ASTM D 3417, ASTM D 3418, ISO 11357-6Features: 1. Rich information is shown on an industrial-grade 7-inch touch screen.2.
Contact Now
It is auto-analyzer used Karl Fischer titration method,determination moisture content.Standards:ISO 10337,ASTM D 1744, ISO 760 , ASTM E203Features:1. New speed drop function, use automatic control electrode polarization voltage drop speed, measure a sample requires only tens of seconds2. Additional current meter makes the titration process more intuitive3. Entire fluid path is made of special materials selection, excellent corrosion resistance, to ensure long-term continuous operation4.
Contact Now
Used for testing the stiffness of all kinds of woven and knit goods, nonwoven fabrics and coated fabrics, including cotton, wool, silk, linen and chemical fiber, and also of flexible materials such as paper, leather, filmRelevant Standards:ZB WO4003, ISO 9073, ASTM D 1388, ISO9073-7, BS En22313Warranty1 yearCustomized supportOEMPlace of OriginChinaShandongBrand NameSKZWorking patternMicro-computer controlled, infrared stealth slant detecting, liquid crystal display, printing out testing resultsTesting range40.5, 43, 45( adjustable)Extension elongation0.5-20.5cmTesting accuracy0.01 cmSpecimen s
Contact Now
SKZ1018B Karl Fischer Volumetric TitrationKarl Fischer titration method is utilized by the auto-analyzer to determine moisture content.Standards:ISO 10337,ASTM D 1744, ISO 760 , ASTM E203Qualities:1.A new speed drop function that measures a sample in tens of seconds using automatic control electrode polarization voltage drop speed2.Having an extra current meter makes the titration procedure easier to understand.3.Specially selected materials with exceptional corrosion resistance make up the whole fluid route, ensuring long-term continuous operation.4.The termination titration, which uses
Contact Now
Volumetric Karl Fischer Titration SKZ1018BIt is auto-analyzer used Karl Fischer titration method,determination moisture content.Standards:ISO 10337,ASTM D 1744, ISO 760 , ASTM E203Features:1. New speed drop function, use automatic control electrode polarization voltage drop speed, measure a sample requires only tens of seconds2. Additional current meter makes the titration process more intuitive3. Entire fluid path is made of special materials selection, excellent corrosion resistance, to ensure long-term continuous operation4.
Contact Now
SKZ1018B Volumetric Karl Fischer TitrationIt is auto-analyzer used Karl Fischer titration method,determination moisture content. Standards:ISO 10337,ASTM D 1744, ISO 760 , ASTM E203Features:1. New pace drop function, use computerized manage electrode polarization voltage drop speed, measure a pattern requires solely tens of seconds2. Additional cutting-edge meter makes the titration procedure extra intuitive3.
Contact Now
SKZ1018C Fully Automatic Volumetric Karl Fischer TitrationAdopted Karl Fischer volumetric moisture can be measured liquids, solids and gases in the sample crystal water, adsorbed water, free water. StandardsISO 10337,ASTM D 1744, ISO 760 , ASTM E203Feature1. Huge variety LCD show, English menu activity.2. Full powerful showcase, WINDOWS working style simple to utilize.3. Shown at the same time (dampness content, rate, PPM content, reagent utilization), variety titration bend dynamic showcase4.
Contact Now
SKZ1018B Karl Fischer Moisture Water Content Test AnalysisIt is auto-analyzer used Karl Fischer titration method,determination moisture content.Standards:ISO 10337,ASTM D 1744, ISO 760 , ASTM E203Technical parameters:Measuring range3ppm-100% Resolution0.01mlMoisture titration Repeatability≤ 0.01Moisture titration linear correlation coefficient≥ 0.998Capacity error≤ ± 0.002Burette capacity>25mlSensitivity10-6ASKZ1018B VOLUMETRIC KARL FISCHER TITRATIONCan be realized:solvent inhalation,determination,enddisplay (alarm),waste water discharge,mixing by means of itsfunction keys.Complete a
Contact Now
Fully Automatic Volumetric Karl Fischer Titration SKZ1018CAdopted Karl Fischer volumetric moisture can be measured liquids, solids and gases in the sample crystal water, adsorbed water, free water. StandardsISO 10337,ASTM D 1744, ISO 760 , ASTM E203 Feature1. Large color LCD display, English menu operation.2. Full dynamic display, WINDOWS operating style easy to use.3. Displayed simultaneously (moisture content, percentage, PPM content, reagent consumption), color titration curve dynamic display4.
Contact Now
SKZ1018B Efficient Moisture Volumetric Titration EquipmentThe SKZ1018B represents an advanced auto-analyzer that harnesses the Karl Fischer titration methodology for precise moisture content determination, adhering to renowned international standards such as ISO 10337, ASTM D 1744, ISO 760, and ASTM E203.
This state-of-the-art instrument comes packed with a suite of unique features designed to enhance performance and user experience:
1. A revolutionary speed drop mechanism has been implemented, which leverages automated control of the electrode polarization voltage drop pace.
Contact Now
SKZ136 Rubber Impact Resilience Tester DIN 53512 MeterTechnical parameters:Diameter of impactorФ15mmSpecimen specificationФ29mm×12.5mmImpact weight0.35-0.1kgImpact speed1.4+0.6m/sStrain energy density351+112kJ/m³Resilience value error±0.5%Dimension320mm×200mm×360mmWeight20kgSKZ136IMPACT RESILIENCE TESTEREXCELLENT PERFORMANCE,SUPERB TECHNOLOGYMOQ 1 pCFactory direct saleStandard:1S04662,ASTM-D 1054-66,DIN 535125KPRODUCT DISPLAYNDUSTERubber lmpact Resilience TesterThe instrument is the pendulumimpact resiliency tester to measure the resilience cost of vulcanized rubbelSuitable for
Contact Now
SKZ136 Rubber Impact Resilience TesterRubber Impact Resilience Tester is the pendulum impact resiliency tester with energy 0.5J and applied to measure the resilience value of vulcanized rubber with hardness 30—85IRHD. It measures up to ISO4662, ASTM-D 1054-66,DIN 53512. Rubber Impact Resilience Tester is the pendulum impact resiliency tester to measure the resilience value of vulcanized rubber.
Contact Now
SKZ1027A/B/C/D Laboratory Valley Pulp BeaterLaboratory Valley pulp Beater, mechanical forces generated by the roll and the bottom knife, the fiber pulp was cutting, crushing, kneading, split, moistening and fiber thinning, meanwhile, the fiber cell wall displacement and deformation generated, the primary wall and outer wall broken.
Contact Now
SKZ68 three-angle gloss meter can complete the measurement of multiple angles with one click, and the measurement of three angles can be completed at the same time with one operation. IS0 2813 provides three kinds of measuring light incident angles, the three incident angles of the mirror gloss meter are 20°, 60°, 85°.StandardIS02813, 1S07668, ASTM D523, ASTM D2457, GB/T9754, GB/T13891, GB/T7706, GB/T 8807, JG 696-2002Advantages:1.One button to complete triangle measurement: one operation can complete three angle measurement; Measuring light incident angle meet ISO 2813 three me
Contact Now
SKZ165 Martindale Pilling TesterUsed to evaluate how well textiles and membrane materials perform in terms of wearing resistance, abrasion, and appearance change (pilling degree/class).Standards:ASTM D4970,ASTM D4966,ISO12947,JIS L1096,TM112 M&S, FZ/T20020,IWS TM196,ASTM D3886,DIN53863/53865, BS3424/5690,BS EN 388/530,ISO12945-2Test mode:Mode 1: Using a circular specimen made of the same material fabric and friction with a Lissajous graphic motion trajectory, the specimen can reach the necessary speed while assessing sample pilling at a certain pressure.
Contact Now
SKZ145 Melt Flow Rate TesterMelt mass-flow (MFR) (g/10min), melt volume-flow rate (cm3/10min), and the melt density of thermo resin must be determined for engineering plastics, which have higher melt temperatures, such as polycarbonate, nylon, and fluorine plastics; and for fit for plastics tests, which have lower melt temperatures, such as polyethylene, polystyrene, polypropylene, ABS resin, and poly-formaldehyde resin, etc.Standards:ISO 1133-1, ISO 1133-2, GBT 3682.1-2018, ASTM D1238-2013, ASTM D3364-1999 (2011), JJG878-1994, JB/T5456-2016, DIN53735, UNI-5640Product features:1.The control sy
Contact Now
SKZ128 Digital Shore Hardness Tester Plastic and rubber that have been vulcanized are tested for hardness using a shore hardness tester. The stand holds the hardness head in place. To perform spot testing, you can also remove the head from the stand.
Contact Now
Shore hardness tester is applied to test the hardness of vulcanized rubber and plastic. The hardness head is installed on the stand. You can also take the head from the stand to carry spot testing.
Contact Now
The Auto-pneumatic Cutter Press is driven by air pressure only. lt is suitable for laboratory to punch every kind of standard specimens from rubber, plastic, leather Standard: ASTM-D412Technical parameters:TypesPNEUMATICMoving distance25mm~100mmWorking platform320 mm×220 mmSpecimen thicknessmaximum 10mmAir pressure0.6MPaDimension380mm×260mm×590mmNet weight40kg
Contact Now
SKZ132 Mooney ViscometerUsed to calculate the viscosity, scorch, and curing index of raw rubber or rubber compound1. Data display, computer control, and automatic calibration2. Wide temperature range and easily adjustable settings on an imported digital temperature controller3. Making use of the most recent "host + computer + printer" framework concepts Standards: ASTM D1646,ISO 289,JIS K6300,GB/T 1232,GB/T 1233A Control Software Feature is:1. The options' units are kgf-cm, lbf-in Nm, dN-m, and MV;2.
Contact Now
LCD Melt Flow Indexer MRF MVR Meter ISO1133 400degree MFI EquipmentStandards:ISO 1133-1:2011 Plastics — Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics —Part 1:Standard methodISO 1133-2:2011 Plastics — Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics —Part 2: Method for materials sensitive to time temperature history and/or moistureGBT 3682.1-2018 "Plastic Thermoplastic Melt Mass Flow Rate (MFR) and Melt Volume Flow Rate (MVR) Determination"ASTM D1238-2013 "Standard Test Method
Contact Now
SKZ145 Melt Index Tester Mfi TesterFor engineering plastics such as polycarbonate, nylon, and fluorine plastics, whose melt temperatures are higher, as well as fit for plastics tests of polyethylene, polystyrene, polypropylene, ABS resin, and poly-formaldehyde resin, etc., whose melt temperatures are lower, the following parameters must be determined: melt mass-flow (MFR) (g/10min), melt volume-flow rate (cm3/10min), and the melt density of thermo resin.Standards:ISO 1133-1, ISO 1133-2, GBT 3682.1-2018, ASTM D1238-2013, ASTM D3364-1999 (2011), JJG878-1994, JB/T5456-2016, DIN53735, UNI-5640Char
Contact Now
SKZ148 Drop Dart Impact TesterThe impact resistance of plastic films and sheets is tested using a dart impact testing equipment, which uses a background light source to record test findings.StandardISO7765-85, GB9639-88, ASTM D1709 - 09 Technical parametersDart-head weight50-2000g, 5g/incremental (5g*5pcs,15g*15pcs, 30g*10pcs, 45g*10pcs, 80g*10pcs, 90g*15pcs)Dart-head semi-diameterA method: R19±1mm,B method: 25±1mmDart-head accuracy0.1%Impact height660mm, 1500mmImpact energy30JSample clamp deviceexternal dia.: 150mm, inside dia.: 125mmWorking t
Contact Now